-- * Description:   Implements definitions for a HMS based network element
-- *
-- * Copyright 2014 by BKtel communications GmbH
-- *
-- * V.1.0  04.10.2006  M. Heldmann - created this "bkhmsne.mib" file based on BKtel systems "ahmsne.mib" file
-- *                                - marked all parameters that are not used by NMS implementation of BKtel communications GmbH
-- *                                - removed the 'ne' OID definition here and added 'ne' to IMPORTS
-- *                                  because the 'ne' is defined in root mib too
-- * V.1.1  12.05.2014  M. Heldmann - marked all obsolete parameters as 'obsolete' - they may be no more supported by future NEC types and NEC software versions
-- *                                - expanded neModulTable by full inventory information
-- *                                - a couple of renamings
-- *                                - changed name neModulType to neModuleModelName with SYNTAX DisplayString
-- ******************************************************************************************


    BKTEL-HFC862-HMSNE-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        OBJECT-TYPE
            FROM RFC-1212
        TRAP-TYPE
            FROM RFC-1215
        ne, DisplayString, TruthValue, NESlotValue, PerceivedSeverityValue
            FROM BKTEL-HFC862-BASE-MIB
    ;


    neCommon OBJECT IDENTIFIER ::= { ne 1 }

    neType OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Type of NE"
    ::= { neCommon 1 }

    neDescription OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The description of the NE."
    ::= { neCommon 2 }

    neLocationStreet OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "Location Street of Network Element.
             Writable size depends on net element controller, default 32"
    ::= { neCommon 3 }

    neLocationCity OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "Location City of Network Element.
             Writable size depends on net element controller, default 32"
    ::= { neCommon 4 }

    neObsolete_UsingAPS OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neCommon 5 }

    neObsolete_APSMode OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neCommon 6 }

    -- #####+1 Space reserved

    neObsolete_CommonSubrackWidth OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete.
             (The width of the Subracks)"
    ::= { neCommon 8 }

    neObsolete_CommonSubrackNumber OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete.
             (The number of Subracks)"
    ::= { neCommon 9 }

    neObsolete_NumberModul OBJECT-TYPE
        SYNTAX INTEGER (1..61)
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete.
             (Current number of entries in the Modul table)"
    ::= { neCommon 10 }

    neObsolete_UsingRevertiveMode OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neCommon 11 }

    neObsolete_RevertiveMode OBJECT-TYPE
        SYNTAX INTEGER (0..300)
        ACCESS read-write
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neCommon 12 }

    neObsolete_InitPhase OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neCommon 13 }

    neObsolete_PredecessorRedundantPath OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neCommon 14 }

    neObsolete_PredecessorNominalPath OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neCommon 15 }

    neModuleTable OBJECT-TYPE
        SYNTAX SEQUENCE OF NeModuleEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Table containing information about each Module."
    ::= { neCommon 16 }

    neModuleEntry OBJECT-TYPE
        SYNTAX NeModuleEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "List of information about each Module."
        INDEX { neModuleNESlot }
    ::= { neModuleTable 1 }

    NeModuleEntry ::= SEQUENCE
    {
        neModuleNESlot                  NESlotValue,
        neModuleSubrack                 INTEGER,
        neModuleModelName               DisplayString,
        neModuleMibLink                 OBJECT IDENTIFIER,
        neModuleSubrackSlot             INTEGER,
        neModuleSlotUnitsUsed           INTEGER,
        neModuleSlotRackDetection       INTEGER,
        neModuleHousingType             INTEGER,
        neModuleFirmwareVersion         DisplayString,
        neModuleHardwareVersion         DisplayString,
        neModuleDateOfProduction        DisplayString,
        neModuleSerialNumber            DisplayString,
        neModuleArticleNumber           DisplayString,
        neModuleCustomerCode            DisplayString,
        neModuleAliasName               DisplayString,
        neModuleUserdata                DisplayString,
        neModuleReset                   TruthValue,
        neModuleLedBlink                TruthValue
    }

    neModuleNESlot OBJECT-TYPE      -- former neNESlot
        SYNTAX NESlotValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Slot number 
             IMPORTANT NOTE:
                this is a not a physical slot within a module rack, 
                but an assigned slot ID that uniquely identifies each module
                including non subrack based modules as 19 inch modules"
    ::= { neModuleEntry 1 }

    neModuleSubrack OBJECT-TYPE     -- former neSubrack
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Subrack number in which the module is equiped (1 .. N).
             A value of 0 means: No subrack number"
    ::= { neModuleEntry 2 }

    neModuleModelName OBJECT-TYPE   -- former neModulType
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Module model name"
    ::= { neModuleEntry 3 }

    neModuleMibLink OBJECT-TYPE     -- former neModulMibLink
        SYNTAX OBJECT IDENTIFIER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Defines the link to the OID of the equiped module"
    ::= { neModuleEntry 4 }

    -- Expansions, 12.05.2014

    neModuleSubrackSlot OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Slot number within subrack in which the module is equiped (1 .. N).
             A value of 0 means: No slot number"
    ::= { neModuleEntry 5 }

    neModuleSlotUnitsUsed OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used. 
             For all other module types the number of slots within subrack which the module occupies."
    ::= { neModuleEntry 6 }

    neModuleSlotRackDetection OBJECT-TYPE
        SYNTAX INTEGER
        {
            notSupported(1),
            supported(2),
            detectionError(3)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Reports the state of modules slot and rack hardware detection."
    ::= { neModuleEntry 7 }

    neModuleHousingType OBJECT-TYPE
        SYNTAX INTEGER
        {
            housingUnknownOrDefault(1),
            housingBk(2),
            housing2G6(3),
            housing19inch(4)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Module housing type"
    ::= { neModuleEntry 8 }

    neModuleFirmwareVersion OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION "Module firmware version"
    ::= { neModuleEntry 9 }

    neModuleHardwareVersion OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION "Module hardware version"
    ::= { neModuleEntry 10 }

    neModuleDateOfProduction OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION "Module date of production, possible formats:
            - empty string -> no data defined
            - YYYY         -> only the year of production is defined
            - YYYY-MM-DD   -> full date of production is defined"
    ::= { neModuleEntry 11 }

    neModuleSerialNumber OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION "Module serial number"
    ::= { neModuleEntry 12 }

    neModuleArticleNumber OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION "Module article number"
    ::= { neModuleEntry 13 }

    neModuleCustomerCode OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION "Customer specific article code"
    ::= { neModuleEntry 14 }

    neModuleAliasName OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION "Module alias name"
    ::= { neModuleEntry 15 }

    neModuleUserdata OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION "Module user data"
    ::= { neModuleEntry 16 }

    neModuleReset OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Resets the module if this parameter is written to true(1)."
    ::= { neModuleEntry 17 }

    neModuleLedBlink OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION   "Writing this variable to true(1) lets the device's
        modul LED blink green for 10 seconds.
        Writing this variable to false(2) stops blinking at once.
        This variable always returns false(2) on read requests"
    ::= { neModuleEntry 18 }

    neStates OBJECT IDENTIFIER ::= { ne 2 }

    neStatesObsolete_TrapDisable OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neStates 1 }

    neStatesObsolete_TerminalConnected OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neStates 2 }

    -- #####+1 Space reserved

    neStatesObsolete_Isolated OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neStates 4 }

    neStatesObsolete_ResetModullist OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neStates 5 }

    neStatesObsolete_Redundant OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neStates 6 }

    neStatesObsolete_ActivateRedundantPath OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neStates 7 }

    neStatesObsolete_AutoOff OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neStates 8 }

    neConfig OBJECT IDENTIFIER ::= { ne 3 }

    neConfigObsolete_NEtype OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neConfig 1 }

    neConfigObsolete_IPaddress OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neConfig 2 }


    neConfigObsolete_Alarmdelay OBJECT-TYPE
        SYNTAX INTEGER (3..60)
        ACCESS read-write
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neConfig 3 }


    neConfigDeprecated_MinTrapInterval OBJECT-TYPE
        SYNTAX INTEGER (0..10)
        ACCESS read-write
        STATUS optional
        DESCRIPTION
            "This parameter is deprecated.
             (The minimum waiting time between two traps.
              Only used for HMS070 over RS232 interface)"
    ::= { neConfig 4 }

    neConfigDeprecated_MaxTrapLifetime OBJECT-TYPE
        SYNTAX INTEGER (30..300)
        ACCESS read-write
        STATUS optional
        DESCRIPTION
            "This parameter is deprecated.
             (The maximum lifetime of a trap.
              Only used for HMS070 over RS232 interface)"
    ::= { neConfig 5 }



    neControl OBJECT IDENTIFIER ::= { ne 4 }

    neControlTrapDisable OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2)"
    ::= { neControl 1 }

    neControlResetModullist OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This command removes all disconnected (not responding) modules from the module list."
    ::= { neControl 2 }

    neControlObsolete_SetDefaultAPS OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS obsolete
        DESCRIPTION
            "This parameter is obsolete."
    ::= { neControl 3 }




    -- This trap is obsolete and no more supported by new (2014) NECxE 
    neSynchronizeEvent TRAP-TYPE
    ENTERPRISE ne
    DESCRIPTION "The SNMP trap that is generated when data on LMT must get actualized."
    ::= 1


    END