--MWRM-PM-MIB VERSION 1.8.3.1
--MWRM (MicroWave-Radio-MIB)
MWRM-PM-MIB DEFINITIONS ::= BEGIN

IMPORTS
--    Ipv6Address          FROM IPV6-TC
--	Counter, enterprises, Gauge, IpAddress 	FROM RFC1155-SMI
	Counter32, enterprises, Gauge32, IpAddress 	FROM SNMPv2-SMI
	DisplayString, ifIndex  		FROM RFC1213-MIB
	RowStatus						FROM SNMPv2-TC
	MacAddress						FROM SNMPv2-TC
	OBJECT-TYPE          			FROM SNMPv2-SMI
	TRAP-TYPE            			FROM RFC-1215

	EnableDisable			FROM MWRM-UNIT-MIB
	EnableDisableSMI2  		FROM MWRM-UNIT-MIB
	OffOn					FROM MWRM-UNIT-MIB
	MetricImperial			FROM MWRM-UNIT-MIB
	AllowedNotAllowed 		FROM MWRM-UNIT-MIB
	ProgressStatus 			FROM MWRM-UNIT-MIB
	Severity 				FROM MWRM-UNIT-MIB
	NoYes					FROM MWRM-UNIT-MIB
	DownUp					FROM MWRM-UNIT-MIB
	TrailIfType 			FROM MWRM-UNIT-MIB
	PmTableType 			FROM MWRM-UNIT-MIB
	RateMbps				FROM MWRM-UNIT-MIB
	HalfFull				FROM MWRM-UNIT-MIB
	BerLevel				FROM MWRM-UNIT-MIB
	SignalLevel				FROM MWRM-UNIT-MIB
	LoopbackType			FROM MWRM-UNIT-MIB
	QueueName				FROM MWRM-UNIT-MIB
	RadioId					FROM MWRM-UNIT-MIB
	RfuId					FROM MWRM-UNIT-MIB
	SwCommand 				FROM MWRM-UNIT-MIB
	TrailProtectedType		FROM MWRM-UNIT-MIB
	ClockSrc 				FROM MWRM-UNIT-MIB
	SlotId 					FROM MWRM-UNIT-MIB
	Integrity				FROM MWRM-UNIT-MIB
	GreenYellow 			FROM MWRM-UNIT-MIB
	InputSeverity 			FROM MWRM-UNIT-MIB
	SwCommandTimer 			FROM MWRM-UNIT-MIB

	genEquipRadioCfgRadioId FROM MWRM-RADIO-MIB;

microwave-radio OBJECT IDENTIFIER ::= { enterprises 2281 }
genEquip OBJECT IDENTIFIER ::= { microwave-radio 10}
genEquipUnit OBJECT IDENTIFIER ::= { genEquip 1}

-- Performance Monitoring Tables

genEquipPM	OBJECT IDENTIFIER ::= {genEquip 6}

genEquipPmRfu	OBJECT IDENTIFIER ::= {genEquipPM 1}

genEquipPmRfuCommon	OBJECT IDENTIFIER ::= {genEquipPmRfu 1}

genEquipPmRfuCommonSL15minTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRfuCommonSL15minEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table indicates the RFU Signal Level PM data."
        ::= { genEquipPmRfuCommon 1 }

genEquipPmRfuCommonSL15minEntry OBJECT-TYPE
        SYNTAX GenEquipPmRfuCommonSL15minEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Entry containing the data of the RFU SL PM."
        INDEX { genEquipPmRfuCommonSL15minId }
        ::= { genEquipPmRfuCommonSL15minTable 1 }

GenEquipPmRfuCommonSL15minEntry ::=
            SEQUENCE {
		genEquipPmRfuCommonSL15minId			INTEGER,
		genEquipPmRfuCommonSL15minIfIndex		INTEGER,
        genEquipPmRfuCommonSL15minTimeAndDate	DisplayString,
        genEquipPmRfuCommonSL15minMinRsl		INTEGER,
        genEquipPmRfuCommonSL15minMaxRsl		INTEGER,
        genEquipPmRfuCommonSL15minRslExceed1	INTEGER,
        genEquipPmRfuCommonSL15minRslExceed2	INTEGER,
        genEquipPmRfuCommonSL15minMinTsl		INTEGER,
        genEquipPmRfuCommonSL15minMaxTsl		INTEGER,
        genEquipPmRfuCommonSL15minTslExceed		INTEGER,
        genEquipPmRfuCommonSL15minIDF			Integrity
	}

genEquipPmRfuCommonSL15minId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmRfuCommonSL15minEntry 1 }

genEquipPmRfuCommonSL15minIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
		::= { genEquipPmRfuCommonSL15minEntry 2 }

genEquipPmRfuCommonSL15minTimeAndDate	OBJECT-TYPE
		SYNTAX		DisplayString
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the Time and date for the specific PM."
		::= { genEquipPmRfuCommonSL15minEntry 3 }

genEquipPmRfuCommonSL15minMinRsl	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the minimum RSL value."
		::= { genEquipPmRfuCommonSL15minEntry 4 }

genEquipPmRfuCommonSL15minMaxRsl		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the maximum RSL value."
		::= { genEquipPmRfuCommonSL15minEntry 5 }

genEquipPmRfuCommonSL15minRslExceed1		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 1."
		::= { genEquipPmRfuCommonSL15minEntry 6 }

genEquipPmRfuCommonSL15minRslExceed2  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 2."
        ::= { genEquipPmRfuCommonSL15minEntry 7 }

genEquipPmRfuCommonSL15minMinTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Min TSL value."
        ::= { genEquipPmRfuCommonSL15minEntry 8 }

genEquipPmRfuCommonSL15minMaxTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Max TSL value."
        ::= { genEquipPmRfuCommonSL15minEntry 9 }

genEquipPmRfuCommonSL15minTslExceed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds TSL exceeded the threshold"
        ::= { genEquipPmRfuCommonSL15minEntry 10 }

genEquipPmRfuCommonSL15minIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the IDF (Invalid Data Flag) of the interval.
		 integrity(0), nointegrity(1)."
        ::= { genEquipPmRfuCommonSL15minEntry 11 }


-- SL 15 min CURRENT table --

genEquipPmRfuCommonSL15minCurrTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRfuCommonSL15minCurrEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table indicates the RFU Signal Level PM data for the current 15 min. interval."
        ::= { genEquipPmRfuCommon 2 }

genEquipPmRfuCommonSL15minCurrEntry OBJECT-TYPE
        SYNTAX GenEquipPmRfuCommonSL15minCurrEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Entry containing the data of the Rfu SL PM."
        INDEX { genEquipPmRfuCommonSL15minCurrId }
        ::= { genEquipPmRfuCommonSL15minCurrTable 1 }

GenEquipPmRfuCommonSL15minCurrEntry ::=
            SEQUENCE {
		genEquipPmRfuCommonSL15minCurrId			INTEGER,
		genEquipPmRfuCommonSL15minCurrIfIndex		INTEGER,
        genEquipPmRfuCommonSL15minCurrTimeAndDate	DisplayString,
        genEquipPmRfuCommonSL15minCurrMinRsl		INTEGER,
        genEquipPmRfuCommonSL15minCurrMaxRsl		INTEGER,
        genEquipPmRfuCommonSL15minCurrRslExceed1	INTEGER,
        genEquipPmRfuCommonSL15minCurrRslExceed2	INTEGER,
        genEquipPmRfuCommonSL15minCurrMinTsl		INTEGER,
        genEquipPmRfuCommonSL15minCurrMaxTsl		INTEGER,
        genEquipPmRfuCommonSL15minCurrTslExceed		INTEGER,
        genEquipPmRfuCommonSL15minCurrIDF			Integrity
	}

genEquipPmRfuCommonSL15minCurrId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmRfuCommonSL15minCurrEntry 1 }

genEquipPmRfuCommonSL15minCurrIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
		::= { genEquipPmRfuCommonSL15minCurrEntry 2 }

genEquipPmRfuCommonSL15minCurrTimeAndDate	OBJECT-TYPE
		SYNTAX		DisplayString
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the Time and date for the specific PM."
		::= { genEquipPmRfuCommonSL15minCurrEntry 3 }

genEquipPmRfuCommonSL15minCurrMinRsl	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the minimum RSL value."
		::= { genEquipPmRfuCommonSL15minCurrEntry 4 }

genEquipPmRfuCommonSL15minCurrMaxRsl		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the maximum RSL value."
		::= { genEquipPmRfuCommonSL15minCurrEntry 5 }

genEquipPmRfuCommonSL15minCurrRslExceed1		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 1."
		::= { genEquipPmRfuCommonSL15minCurrEntry 6 }

genEquipPmRfuCommonSL15minCurrRslExceed2  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 2."
        ::= { genEquipPmRfuCommonSL15minCurrEntry 7 }

genEquipPmRfuCommonSL15minCurrMinTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Min TSL value."
        ::= { genEquipPmRfuCommonSL15minCurrEntry 8 }

genEquipPmRfuCommonSL15minCurrMaxTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Max TSL value."
        ::= { genEquipPmRfuCommonSL15minCurrEntry 9 }

genEquipPmRfuCommonSL15minCurrTslExceed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds TSL exceeded the threshold"
        ::= { genEquipPmRfuCommonSL15minCurrEntry 10 }

genEquipPmRfuCommonSL15minCurrIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the IDF (Invalid Data Flag) of the current interval.
		 integrity(0), nointegrity(1)."
        ::= { genEquipPmRfuCommonSL15minCurrEntry 11 }

-- PM Tables for SL 24 hour intervals

genEquipPmRfuCommonSL24hrTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRfuCommonSL24hrEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table indicates the RFU Signal Level 24 hr PM data."
        ::= { genEquipPmRfuCommon 3 }

genEquipPmRfuCommonSL24hrEntry OBJECT-TYPE
        SYNTAX GenEquipPmRfuCommonSL24hrEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Entry containing the data of the RFU SL PM."
        INDEX { genEquipPmRfuCommonSL24hrId }
        ::= { genEquipPmRfuCommonSL24hrTable 1 }

GenEquipPmRfuCommonSL24hrEntry ::=
            SEQUENCE {
		genEquipPmRfuCommonSL24hrId				INTEGER,
		genEquipPmRfuCommonSL24hrIfIndex		INTEGER,
        genEquipPmRfuCommonSL24hrTimeAndDate	DisplayString,
        genEquipPmRfuCommonSL24hrMinRsl			INTEGER,
        genEquipPmRfuCommonSL24hrMaxRsl			INTEGER,
        genEquipPmRfuCommonSL24hrRslExceed1		INTEGER,
        genEquipPmRfuCommonSL24hrRslExceed2		INTEGER,
        genEquipPmRfuCommonSL24hrMinTsl			INTEGER,
        genEquipPmRfuCommonSL24hrMaxTsl			INTEGER,
        genEquipPmRfuCommonSL24hrTslExceed		INTEGER,
        genEquipPmRfuCommonSL24hrIDF			Integrity
	}

genEquipPmRfuCommonSL24hrId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmRfuCommonSL24hrEntry 1 }

genEquipPmRfuCommonSL24hrIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
		::= { genEquipPmRfuCommonSL24hrEntry 2 }

genEquipPmRfuCommonSL24hrTimeAndDate	OBJECT-TYPE
		SYNTAX		DisplayString
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the time and date for the specific PM."
		::= { genEquipPmRfuCommonSL24hrEntry 3 }

genEquipPmRfuCommonSL24hrMinRsl	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the min RSL value."
		::= { genEquipPmRfuCommonSL24hrEntry 4 }

genEquipPmRfuCommonSL24hrMaxRsl		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the max RSL value."
		::= { genEquipPmRfuCommonSL24hrEntry 5 }

genEquipPmRfuCommonSL24hrRslExceed1		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 1."
		::= { genEquipPmRfuCommonSL24hrEntry 6 }

genEquipPmRfuCommonSL24hrRslExceed2  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 2."
        ::= { genEquipPmRfuCommonSL24hrEntry 7 }

genEquipPmRfuCommonSL24hrMinTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Min TSL value."
        ::= { genEquipPmRfuCommonSL24hrEntry 8 }

genEquipPmRfuCommonSL24hrMaxTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Max TSL value."
        ::= { genEquipPmRfuCommonSL24hrEntry 9 }

genEquipPmRfuCommonSL24hrTslExceed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded the threshold"
        ::= { genEquipPmRfuCommonSL24hrEntry 10 }

genEquipPmRfuCommonSL24hrIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the IDF (Invalid Data Flag) of the interval.
		 integrity(0), nointegrity(1)."
        ::= { genEquipPmRfuCommonSL24hrEntry 11 }


-- SL 24 HR CURRENT table --

genEquipPmRfuCommonSL24hrCurrTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRfuCommonSL24hrCurrEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table indicates the RFU Signal Level PM data for the current 24 hour interval."
        ::= { genEquipPmRfuCommon 4 }

genEquipPmRfuCommonSL24hrCurrEntry OBJECT-TYPE
        SYNTAX GenEquipPmRfuCommonSL24hrCurrEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Entry containing the data of the RFU SL PM."
        INDEX { genEquipPmRfuCommonSL24hrCurrId }
        ::= { genEquipPmRfuCommonSL24hrCurrTable 1 }

GenEquipPmRfuCommonSL24hrCurrEntry ::=
            SEQUENCE {
		genEquipPmRfuCommonSL24hrCurrId				INTEGER,
		genEquipPmRfuCommonSL24hrCurrIfIndex		INTEGER,
        genEquipPmRfuCommonSL24hrCurrTimeAndDate	DisplayString,
        genEquipPmRfuCommonSL24hrCurrMinRsl			INTEGER,
        genEquipPmRfuCommonSL24hrCurrMaxRsl			INTEGER,
        genEquipPmRfuCommonSL24hrCurrRslExceed1		INTEGER,
        genEquipPmRfuCommonSL24hrCurrRslExceed2		INTEGER,
        genEquipPmRfuCommonSL24hrCurrMinTsl			INTEGER,
        genEquipPmRfuCommonSL24hrCurrMaxTsl			INTEGER,
        genEquipPmRfuCommonSL24hrCurrTslExceed		INTEGER,
        genEquipPmRfuCommonSL24hrCurrIDF			Integrity
	}

genEquipPmRfuCommonSL24hrCurrId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmRfuCommonSL24hrCurrEntry 1 }

genEquipPmRfuCommonSL24hrCurrIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
		::= { genEquipPmRfuCommonSL24hrCurrEntry 2 }

genEquipPmRfuCommonSL24hrCurrTimeAndDate	OBJECT-TYPE
		SYNTAX		DisplayString
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the time and date for the specific PM."
		::= { genEquipPmRfuCommonSL24hrCurrEntry 3 }

genEquipPmRfuCommonSL24hrCurrMinRsl	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the min RSL value."
		::= { genEquipPmRfuCommonSL24hrCurrEntry 4 }

genEquipPmRfuCommonSL24hrCurrMaxRsl		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the Max RSL value."
		::= { genEquipPmRfuCommonSL24hrCurrEntry 5 }

genEquipPmRfuCommonSL24hrCurrRslExceed1		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 1."
		::= { genEquipPmRfuCommonSL24hrCurrEntry 6 }

genEquipPmRfuCommonSL24hrCurrRslExceed2  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 2."
        ::= { genEquipPmRfuCommonSL24hrCurrEntry 7 }

genEquipPmRfuCommonSL24hrCurrMinTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Min TSL value."
        ::= { genEquipPmRfuCommonSL24hrCurrEntry 8 }

genEquipPmRfuCommonSL24hrCurrMaxTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Max TSL value."
        ::= { genEquipPmRfuCommonSL24hrCurrEntry 9 }

genEquipPmRfuCommonSL24hrCurrTslExceed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds TSL exceeded the threshold"
        ::= { genEquipPmRfuCommonSL24hrCurrEntry 10 }

genEquipPmRfuCommonSL24hrCurrIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the IDF (Invalid Data Flag) of the interval.
		 integrity(0), nointegrity(1)."
        ::= { genEquipPmRfuCommonSL24hrCurrEntry 11 }



--	PM for Radio Aggregate - 15 min intervals

genEquipPmTraffic	OBJECT IDENTIFIER ::= {genEquipPM 2}

genEquipPmTrafficRadioAgg15minTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmTrafficRadioAgg15minEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table indicates the Radio Aggregate PM data for all 15 min intervals."
        ::= { genEquipPmTraffic 1 }

genEquipPmTrafficRadioAgg15minEntry OBJECT-TYPE
        SYNTAX GenEquipPmTrafficRadioAgg15minEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table indicates the Radio Aggregate PM data for all 15 min intervals."
        INDEX { genEquipPmTrafficRadioAgg15minId }
        ::= { genEquipPmTrafficRadioAgg15minTable 1 }

GenEquipPmTrafficRadioAgg15minEntry ::=
            SEQUENCE {
		genEquipPmTrafficRadioAgg15minId				INTEGER,
		genEquipPmTrafficRadioAgg15minIfIndex		INTEGER,
        genEquipPmTrafficRadioAgg15minTimeAndDate	DisplayString,
        genEquipPmTrafficRadioAgg15minES				INTEGER,
        genEquipPmTrafficRadioAgg15minSES			INTEGER,
        genEquipPmTrafficRadioAgg15minUAS			INTEGER,
        genEquipPmTrafficRadioAgg15minBBE			INTEGER,
        genEquipPmTrafficRadioAgg15minIDF			Integrity
	}

genEquipPmTrafficRadioAgg15minId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmTrafficRadioAgg15minEntry 1 }

genEquipPmTrafficRadioAgg15minIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
		::= { genEquipPmTrafficRadioAgg15minEntry 2 }

genEquipPmTrafficRadioAgg15minTimeAndDate	OBJECT-TYPE
		SYNTAX		DisplayString
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the time and date for the specific PM."
		::= { genEquipPmTrafficRadioAgg15minEntry 3 }

genEquipPmTrafficRadioAgg15minES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the ES value."
		::= { genEquipPmTrafficRadioAgg15minEntry 4 }

genEquipPmTrafficRadioAgg15minSES		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the SES value."
		::= { genEquipPmTrafficRadioAgg15minEntry 5 }

genEquipPmTrafficRadioAgg15minUAS		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the UAS value."
		::= { genEquipPmTrafficRadioAgg15minEntry 6 }

genEquipPmTrafficRadioAgg15minBBE  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the BBE value."
        ::= { genEquipPmTrafficRadioAgg15minEntry 7 }


genEquipPmTrafficRadioAgg15minIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the IDF (Invalid Data Flag) of the interval.
		 integrity(0), nointegrity(1)."
        ::= { genEquipPmTrafficRadioAgg15minEntry 8 }

-- PM for Radio Agg. - 15min - Current interval

genEquipPmTrafficRadioAgg15minCurrTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmTrafficRadioAgg15minCurrEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table indicates the Radio Aggregate PM data for all 15 min intervals."
        ::= { genEquipPmTraffic 2 }

genEquipPmTrafficRadioAgg15minCurrEntry OBJECT-TYPE
        SYNTAX GenEquipPmTrafficRadioAgg15minCurrEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table indicates the Radio Aggregate PM data for all 15 min intervals."
        INDEX { genEquipPmTrafficRadioAgg15minCurrId }
        ::= { genEquipPmTrafficRadioAgg15minCurrTable 1 }

GenEquipPmTrafficRadioAgg15minCurrEntry ::=
            SEQUENCE {
		genEquipPmTrafficRadioAgg15minCurrId				INTEGER,
		genEquipPmTrafficRadioAgg15minCurrIfIndex		INTEGER,
        genEquipPmTrafficRadioAgg15minCurrTimeAndDate	DisplayString,
        genEquipPmTrafficRadioAgg15minCurrES				INTEGER,
        genEquipPmTrafficRadioAgg15minCurrSES			INTEGER,
        genEquipPmTrafficRadioAgg15minCurrUAS			INTEGER,
        genEquipPmTrafficRadioAgg15minCurrBBE			INTEGER,
        genEquipPmTrafficRadioAgg15minCurrIDF			Integrity
	}

genEquipPmTrafficRadioAgg15minCurrId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmTrafficRadioAgg15minCurrEntry 1 }

genEquipPmTrafficRadioAgg15minCurrIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
		::= { genEquipPmTrafficRadioAgg15minCurrEntry 2 }

genEquipPmTrafficRadioAgg15minCurrTimeAndDate	OBJECT-TYPE
		SYNTAX		DisplayString
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the time and date for the specific PM."
		::= { genEquipPmTrafficRadioAgg15minCurrEntry 3 }

genEquipPmTrafficRadioAgg15minCurrES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the ES value."
		::= { genEquipPmTrafficRadioAgg15minCurrEntry 4 }

genEquipPmTrafficRadioAgg15minCurrSES		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the SES value."
		::= { genEquipPmTrafficRadioAgg15minCurrEntry 5 }

genEquipPmTrafficRadioAgg15minCurrUAS		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the UAS value."
		::= { genEquipPmTrafficRadioAgg15minCurrEntry 6 }

genEquipPmTrafficRadioAgg15minCurrBBE  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the BBE value."
        ::= { genEquipPmTrafficRadioAgg15minCurrEntry 7 }


genEquipPmTrafficRadioAgg15minCurrIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the IDF (Invalid Data Flag) of the interval.
		 integrity(0), nointegrity(1)."
        ::= { genEquipPmTrafficRadioAgg15minCurrEntry 8 }

-- PM for Radio Aggregate - 24 hours intervals

genEquipPmTrafficRadioAgg24hrTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmTrafficRadioAgg24hrEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table indicates the Radio Aggregate PM data for all 15 min intervals."
        ::= { genEquipPmTraffic 3 }

genEquipPmTrafficRadioAgg24hrEntry OBJECT-TYPE
        SYNTAX GenEquipPmTrafficRadioAgg24hrEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table indicates the Radio Aggregate PM data for all 15 min intervals."
        INDEX { genEquipPmTrafficRadioAgg24hrId }
        ::= { genEquipPmTrafficRadioAgg24hrTable 1 }

GenEquipPmTrafficRadioAgg24hrEntry ::=
            SEQUENCE {
		genEquipPmTrafficRadioAgg24hrId			INTEGER,
		genEquipPmTrafficRadioAgg24hrIfIndex		INTEGER,
        genEquipPmTrafficRadioAgg24hrTimeAndDate	DisplayString,
        genEquipPmTrafficRadioAgg24hrES			INTEGER,
        genEquipPmTrafficRadioAgg24hrSES			INTEGER,
        genEquipPmTrafficRadioAgg24hrUAS			INTEGER,
        genEquipPmTrafficRadioAgg24hrBBE			INTEGER,
        genEquipPmTrafficRadioAgg24hrIDF			Integrity
	}

genEquipPmTrafficRadioAgg24hrId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmTrafficRadioAgg24hrEntry 1 }

genEquipPmTrafficRadioAgg24hrIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
		::= { genEquipPmTrafficRadioAgg24hrEntry 2 }

genEquipPmTrafficRadioAgg24hrTimeAndDate	OBJECT-TYPE
		SYNTAX		DisplayString
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the time and date for the specific PM."
		::= { genEquipPmTrafficRadioAgg24hrEntry 3 }

genEquipPmTrafficRadioAgg24hrES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the ES value."
		::= { genEquipPmTrafficRadioAgg24hrEntry 4 }

genEquipPmTrafficRadioAgg24hrSES		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the SES value."
		::= { genEquipPmTrafficRadioAgg24hrEntry 5 }

genEquipPmTrafficRadioAgg24hrUAS		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the UAS value."
		::= { genEquipPmTrafficRadioAgg24hrEntry 6 }

genEquipPmTrafficRadioAgg24hrBBE  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the BBE value."
        ::= { genEquipPmTrafficRadioAgg24hrEntry 7 }


genEquipPmTrafficRadioAgg24hrIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the IDF (Invalid Data Flag) of the interval.
		 integrity(0), nointegrity(1)."
        ::= { genEquipPmTrafficRadioAgg24hrEntry 8 }

-- PM for Radio Agg. - 24hr - Current interval

genEquipPmTrafficRadioAgg24hrCurrTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmTrafficRadioAgg24hrCurrEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table indicates the Radio Aggregate PM data for all 15 min intervals."
        ::= { genEquipPmTraffic 4 }

genEquipPmTrafficRadioAgg24hrCurrEntry OBJECT-TYPE
        SYNTAX GenEquipPmTrafficRadioAgg24hrCurrEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table indicates the Radio Aggregate PM data for all 15 min intervals."
        INDEX { genEquipPmTrafficRadioAgg24hrCurrId }
        ::= { genEquipPmTrafficRadioAgg24hrCurrTable 1 }

GenEquipPmTrafficRadioAgg24hrCurrEntry ::=
            SEQUENCE {
		genEquipPmTrafficRadioAgg24hrCurrId			INTEGER,
		genEquipPmTrafficRadioAgg24hrCurrIfIndex		INTEGER,
        genEquipPmTrafficRadioAgg24hrCurrTimeAndDate	DisplayString,
        genEquipPmTrafficRadioAgg24hrCurrES			INTEGER,
        genEquipPmTrafficRadioAgg24hrCurrSES			INTEGER,
        genEquipPmTrafficRadioAgg24hrCurrUAS			INTEGER,
        genEquipPmTrafficRadioAgg24hrCurrBBE			INTEGER,
        genEquipPmTrafficRadioAgg24hrCurrIDF			Integrity
	}

genEquipPmTrafficRadioAgg24hrCurrId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmTrafficRadioAgg24hrCurrEntry 1 }

genEquipPmTrafficRadioAgg24hrCurrIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU (as appears in the ifTable)"
		::= { genEquipPmTrafficRadioAgg24hrCurrEntry 2 }

genEquipPmTrafficRadioAgg24hrCurrTimeAndDate	OBJECT-TYPE
		SYNTAX		DisplayString
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the time and date for the specific PM."
		::= { genEquipPmTrafficRadioAgg24hrCurrEntry 3 }

genEquipPmTrafficRadioAgg24hrCurrES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the ES value."
		::= { genEquipPmTrafficRadioAgg24hrCurrEntry 4 }

genEquipPmTrafficRadioAgg24hrCurrSES		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the SES value."
		::= { genEquipPmTrafficRadioAgg24hrCurrEntry 5 }

genEquipPmTrafficRadioAgg24hrCurrUAS		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the UAS value."
		::= { genEquipPmTrafficRadioAgg24hrCurrEntry 6 }

genEquipPmTrafficRadioAgg24hrCurrBBE  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the BBE value."
        ::= { genEquipPmTrafficRadioAgg24hrCurrEntry 7 }


genEquipPmTrafficRadioAgg24hrCurrIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the IDF (Invalid Data Flag) of the current interval.
		 integrity(0), nointegrity(1)."
        ::= { genEquipPmTrafficRadioAgg24hrCurrEntry 8 }




-- 	New PM tables - Add PM Table Type to the tables as index.
genEquipPmAll	OBJECT IDENTIFIER ::= {genEquipPM 3}

genEquipPmClear  OBJECT-TYPE
		SYNTAX  OffOn
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"Clear All values for PM tables."
        ::= { genEquipPmAll 1 }


-- 	Signal Level PM Group
genEquipPmTrafficSL	OBJECT IDENTIFIER ::= {genEquipPmAll 2}

genEquipPmTrafficSLTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmTrafficSLEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table indicates the RFU Signal Level PM data."
        ::= { genEquipPmTrafficSL 1 }

genEquipPmTrafficSLEntry OBJECT-TYPE
        SYNTAX GenEquipPmTrafficSLEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Entry containing the data of the RFU signal level PM."
        INDEX { genEquipPmTrafficSLPmType, genEquipPmTrafficSLId, genEquipPmTrafficSLInterval }
        ::= { genEquipPmTrafficSLTable 1 }

GenEquipPmTrafficSLEntry ::=
            SEQUENCE {
		genEquipPmTrafficSLPmType		PmTableType,
		genEquipPmTrafficSLId			RfuId,
		genEquipPmTrafficSLInterval		INTEGER,
        genEquipPmTrafficSLMinRsl		INTEGER,
        genEquipPmTrafficSLMaxRsl		INTEGER,
        genEquipPmTrafficSLRslExceed1	INTEGER,
        genEquipPmTrafficSLRslExceed2	INTEGER,
        genEquipPmTrafficSLMinTsl		INTEGER,
        genEquipPmTrafficSLMaxTsl		INTEGER,
        genEquipPmTrafficSLTslExceed	INTEGER,
        genEquipPmTrafficSLIDF			Integrity
	}

genEquipPmTrafficSLPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmTrafficSLEntry 1 }

genEquipPmTrafficSLId OBJECT-TYPE
        SYNTAX  RfuId
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmTrafficSLEntry 2 }

genEquipPmTrafficSLInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific PM Interval"
        ::= { genEquipPmTrafficSLEntry 3 }

genEquipPmTrafficSLMinRsl	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the min RSL value."
		::= { genEquipPmTrafficSLEntry 4 }

genEquipPmTrafficSLMaxRsl		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the max RSL value."
		::= { genEquipPmTrafficSLEntry 5 }

genEquipPmTrafficSLRslExceed1		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 1."
		::= { genEquipPmTrafficSLEntry 6 }

genEquipPmTrafficSLRslExceed2  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds RSL exceeded threshold number 2."
        ::= { genEquipPmTrafficSLEntry 7 }

genEquipPmTrafficSLMinTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Minimum TSL value."
        ::= { genEquipPmTrafficSLEntry 8 }

genEquipPmTrafficSLMaxTsl  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the Maximum TSL value."
        ::= { genEquipPmTrafficSLEntry 9 }

genEquipPmTrafficSLTslExceed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the number of seconds TSL exceeded the threshold"
        ::= { genEquipPmTrafficSLEntry 10 }

genEquipPmTrafficSLIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmTrafficSLEntry 11 }

-- 	Aggregate PM Group
genEquipPmTrafficAggregate	OBJECT IDENTIFIER ::= {genEquipPmAll 3}

genEquipPmTrafficAggTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmTrafficAggEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table indicates the Radio Aggregate PM data."
        ::= { genEquipPmTrafficAggregate 1 }

genEquipPmTrafficAggEntry OBJECT-TYPE
        SYNTAX GenEquipPmTrafficAggEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table indicates the Radio Aggregate PM data."
        INDEX { genEquipPmTrafficAggPmType, ifIndex, genEquipPmTrafficAggInterval }
        ::= { genEquipPmTrafficAggTable 1 }

GenEquipPmTrafficAggEntry ::=
            SEQUENCE {
		genEquipPmTrafficAggPmType			PmTableType,
		genEquipPmTrafficAggInterval		INTEGER,
        genEquipPmTrafficAggES				INTEGER,
        genEquipPmTrafficAggSES				INTEGER,
        genEquipPmTrafficAggUAS				INTEGER,
        genEquipPmTrafficAggBBE				INTEGER,
        genEquipPmTrafficAggIDF				Integrity
	}

genEquipPmTrafficAggPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmTrafficAggEntry 1 }

genEquipPmTrafficAggInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific PM Interval"
        ::= { genEquipPmTrafficAggEntry 2 }

genEquipPmTrafficAggES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the ES value (Errored seconds)."
		::= { genEquipPmTrafficAggEntry 3 }

genEquipPmTrafficAggSES		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the SES value (Severe Errored seconds)."
		::= { genEquipPmTrafficAggEntry 4 }

genEquipPmTrafficAggUAS		OBJECT-TYPE
		SYNTAX 		INTEGER
		ACCESS		read-only
        STATUS		mandatory
        DESCRIPTION
		"This value indicates the UAS value. (Unavailable Seconds)"
		::= { genEquipPmTrafficAggEntry 5 }

genEquipPmTrafficAggBBE  OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the BBE value. (Background Block Error)"
        ::= { genEquipPmTrafficAggEntry 6 }


genEquipPmTrafficAggIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmTrafficAggEntry 7 }



-- 	Radio PM Group
genEquipPmRadio	OBJECT IDENTIFIER ::= {genEquipPmAll 4}

-- 	Radio MRMC PM Group
genEquipPmRadioMRMC	OBJECT IDENTIFIER ::= {genEquipPmRadio 1}

-- Radio MRMC PM Table
genEquipPmRadioMRMCTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRadioMRMCEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The MRMC PM table"
        ::= { genEquipPmRadioMRMC 1 }

genEquipPmRadioMRMCEntry OBJECT-TYPE
        SYNTAX GenEquipPmRadioMRMCEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The MRMC PM table"
        INDEX { genEquipPmRadioMRMCPmType, genEquipPmRadioMRMCId, genEquipPmRadioMRMCInterval }
        ::= { genEquipPmRadioMRMCTable 1 }

GenEquipPmRadioMRMCEntry ::=
            SEQUENCE {
		genEquipPmRadioMRMCPmType			PmTableType,
		genEquipPmRadioMRMCId				RadioId,
		genEquipPmRadioMRMCInterval			INTEGER,
		genEquipPmRadioMRMCIfIndex			INTEGER,
        genEquipPmRadioMRMCMinProfile		INTEGER,
        genEquipPmRadioMRMCMaxProfile		INTEGER,
        genEquipPmRadioMRMCMinBitrate		INTEGER,
        genEquipPmRadioMRMCMaxBitrate		INTEGER,
        genEquipPmRadioMRMCMinTDMIf			INTEGER,
        genEquipPmRadioMRMCMaxTDMIf			INTEGER,
        genEquipPmRadioMRMCIDF				Integrity
	}

genEquipPmRadioMRMCPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmRadioMRMCEntry 1 }

genEquipPmRadioMRMCId OBJECT-TYPE
        SYNTAX  RadioId
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific RFU"
        ::= { genEquipPmRadioMRMCEntry 2 }

genEquipPmRadioMRMCInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates an index of a specific PM Interval"
        ::= { genEquipPmRadioMRMCEntry 3 }

genEquipPmRadioMRMCIfIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS 	mandatory
		DESCRIPTION
		"This value indicates the interface index of a specific RFU interface (as appears in the ifTable)"
		::= { genEquipPmRadioMRMCEntry 4 }

genEquipPmRadioMRMCMinProfile	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Minimum MRMC profile."
		::= { genEquipPmRadioMRMCEntry 5 }

genEquipPmRadioMRMCMaxProfile	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"The maximum profile (Kbps) that was measured during the interva"
		::= { genEquipPmRadioMRMCEntry 6 }

genEquipPmRadioMRMCMinBitrate	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Minimum MRMC nominal bitrate (Units are Kbps)"
		::= { genEquipPmRadioMRMCEntry 7 }

genEquipPmRadioMRMCMaxBitrate	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Maximum MRMC nominal bitrate (Units are Kbps)"
		::= { genEquipPmRadioMRMCEntry 8 }

genEquipPmRadioMRMCMinTDMIf	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Minimum number of allocated TDM channels"
		::= { genEquipPmRadioMRMCEntry 9 }

genEquipPmRadioMRMCMaxTDMIf	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Maximum number of allocated TDM channels"
		::= { genEquipPmRadioMRMCEntry 10 }

genEquipPmRadioMRMCIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmRadioMRMCEntry 11 }



-- 	Radio E1/T1 PM Group
genEquipPmRadioTDM	OBJECT IDENTIFIER ::= {genEquipPmRadio 2}

-- Radio E1/T1 TDM PM Table
genEquipPmRadioTDMTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRadioTDMEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The PM table of logical TDM channels within the Radio link"
        ::= { genEquipPmRadioTDM 1 }

genEquipPmRadioTDMEntry OBJECT-TYPE
        SYNTAX GenEquipPmRadioTDMEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The PM table of logical TDM channels within the Radio link"
        INDEX { genEquipPmRadioTDMPmType, ifIndex, genEquipPmRadioTDMInterval }
        ::= { genEquipPmRadioTDMTable 1 }

GenEquipPmRadioTDMEntry ::=
            SEQUENCE {
		genEquipPmRadioTDMPmType				PmTableType,
		genEquipPmRadioTDMInterval				INTEGER,
        genEquipPmRadioTDMRadioUAS				INTEGER,
        genEquipPmRadioTDMIDF					Integrity
	}

genEquipPmRadioTDMPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmRadioTDMEntry 1 }

genEquipPmRadioTDMInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM"
        ::= { genEquipPmRadioTDMEntry 2 }

genEquipPmRadioTDMRadioUAS	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"TDM channel UAS (unavailable seconds)"
		::= { genEquipPmRadioTDMEntry 3 }

genEquipPmRadioTDMIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmRadioTDMEntry 4 }


-- 	Radio Ethernet PM Group
genEquipPmRadioEthernet	OBJECT IDENTIFIER ::= {genEquipPmRadio 3}

-- Radio E1/T1 TDM PM Table
genEquipPmRadioEthernetTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRadioEthernetEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The Ethernet PMs on the radio link"
        ::= { genEquipPmRadioEthernet 1 }

genEquipPmRadioEthernetEntry OBJECT-TYPE
        SYNTAX GenEquipPmRadioEthernetEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The Ethernet PMs on the radio link"
        INDEX { genEquipPmRadioEthernetPmType, ifIndex, genEquipPmRadioEthernetInterval }
        ::= { genEquipPmRadioEthernetTable 1 }

GenEquipPmRadioEthernetEntry ::=
            SEQUENCE {
		genEquipPmRadioEthernetPmType				PmTableType,
		genEquipPmRadioEthernetInterval				INTEGER,
		genEquipPmRadioEthernetFrameErrorRate		INTEGER,
		genEquipPmRadioEthernetPeakThroughput		INTEGER,
		genEquipPmRadioEthernetAverageThroughput	INTEGER,
		genEquipPmRadioEthernetExceedThroughput		INTEGER,
		genEquipPmRadioEthernetPeakCapacity			INTEGER,
		genEquipPmRadioEthernetAverageCapacity		INTEGER,
		genEquipPmRadioEthernetExceedCapacity		INTEGER,
		genEquipPmRadioEthernetPeakUtilization		INTEGER,
		genEquipPmRadioEthernetAverageUtilization	INTEGER,
		genEquipPmRadioEthernetExceedUtilization	INTEGER,
        genEquipPmRadioEthernetIDF					Integrity
	}

genEquipPmRadioEthernetPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmRadioEthernetEntry 1 }


genEquipPmRadioEthernetInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM"
        ::= { genEquipPmRadioEthernetEntry 2 }

genEquipPmRadioEthernetFrameErrorRate	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Frame Error Rate PM"
		::= { genEquipPmRadioEthernetEntry 3 }

genEquipPmRadioEthernetPeakThroughput	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Peak throughput PM (Units are bits per second)"
		::= { genEquipPmRadioEthernetEntry 4 }

genEquipPmRadioEthernetAverageThroughput	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Average throughput PM (Units are bits per second)"
		::= { genEquipPmRadioEthernetEntry 5 }

genEquipPmRadioEthernetExceedThroughput	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Exceed throughput PM"
		::= { genEquipPmRadioEthernetEntry 6 }

genEquipPmRadioEthernetPeakCapacity	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Peak capacity PM (in bps)"
		::= { genEquipPmRadioEthernetEntry 7 }

genEquipPmRadioEthernetAverageCapacity	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Average capacity PM (in bps)"
		::= { genEquipPmRadioEthernetEntry 8 }

genEquipPmRadioEthernetExceedCapacity	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Exceed capacity PM"
		::= { genEquipPmRadioEthernetEntry 9 }

genEquipPmRadioEthernetPeakUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Peak utilization PM (%)"
		::= { genEquipPmRadioEthernetEntry 10 }

genEquipPmRadioEthernetAverageUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Average utilization PM (%)"
		::= { genEquipPmRadioEthernetEntry 11 }

genEquipPmRadioEthernetExceedUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Ethernet Exceed utilization PM"
		::= { genEquipPmRadioEthernetEntry 12 }

genEquipPmRadioEthernetIDF  OBJECT-TYPE
		SYNTAX  Integrity
		ACCESS  read-only
		STATUS mandatory
		DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
		::= { genEquipPmRadioEthernetEntry 13 }

-- 	Radio Thresholds

genEquipPmRadioEthernetThresholdTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRadioEthernetThresholdEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The Ethernet PMs on the radio link"
        ::= { genEquipPmRadioEthernet 2 }

genEquipPmRadioEthernetThresholdEntry OBJECT-TYPE
        SYNTAX GenEquipPmRadioEthernetThresholdEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The Ethernet PMs on the radio link"
        INDEX { genEquipRadioCfgRadioId }
        ::= { genEquipPmRadioEthernetThresholdTable 1 }

GenEquipPmRadioEthernetThresholdEntry ::=
	SEQUENCE {
		genEquipPmRadioEthernetThresholdThroughput		INTEGER,
		genEquipPmRadioEthernetThresholdCapacity		INTEGER,
		genEquipPmRadioEthernetThresholdUtilization		INTEGER
	}

genEquipPmRadioEthernetThresholdThroughput  OBJECT-TYPE
		SYNTAX  INTEGER (0..1000)
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"Ethernet Throughput threshold (in Mbps)"
        ::= { genEquipPmRadioEthernetThresholdEntry 1 }

genEquipPmRadioEthernetThresholdCapacity  OBJECT-TYPE
		SYNTAX  INTEGER (0..1000)
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"Ethernet capacity threshold (in Mbps)"
        ::= { genEquipPmRadioEthernetThresholdEntry 2 }

genEquipPmRadioEthernetThresholdUtilization  OBJECT-TYPE
		SYNTAX  INTEGER {
			 above-0(0),
			 above-20(1),
			 above-40(2),
			 above-60(3),
			 above-80(4),
			 no-threshold(5)}
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"Ethernet utilization threshold (in percentage)."
        ::= { genEquipPmRadioEthernetThresholdEntry 3 }

-- 	The Ethernet ETM PMs on the radio link
genEquipPmRadioEthernetEtmTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRadioEthernetEtmEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The Ethernet PMs on the radio link"
        ::= { genEquipPmRadioEthernet 3 }

genEquipPmRadioEthernetEtmEntry OBJECT-TYPE
        SYNTAX GenEquipPmRadioEthernetEtmEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The entry of Ethernet ETM PMs on the radio link"
        INDEX { genEquipPmRadioEthernetEtmPmType, genEquipPmRadioEthernetEtmPmQueueIndex, genEquipPmRadioEthernetEtmInterval }
        ::= { genEquipPmRadioEthernetEtmTable 1 }

GenEquipPmRadioEthernetEtmEntry ::=
	SEQUENCE {
		genEquipPmRadioEthernetEtmPmType
			PmTableType,
		genEquipPmRadioEthernetEtmPmQueueIndex
			INTEGER,
		genEquipPmRadioEthernetEtmInterval
			INTEGER,
		genEquipPmRadioEthernetEtmPmMaxGreenBytesPassed
			INTEGER,
		genEquipPmRadioEthernetEtmPmAvgGreenBytesPassed
			INTEGER,
		genEquipPmRadioEthernetEtmPmMaxGreenFramesDropped
			INTEGER,
		genEquipPmRadioEthernetEtmPmAvgGreenFramesDropped
			INTEGER,
		genEquipPmRadioEthernetEtmPmMaxYellowBytesPassed
			INTEGER,
		genEquipPmRadioEthernetEtmPmAvgYellowBytesPassed
			INTEGER,
		genEquipPmRadioEthernetEtmPmMaxYellowFramesDropped
			INTEGER,
		genEquipPmRadioEthernetEtmPmAvgYellowFramesDropped
			INTEGER,
		genEquipPmRadioEthernetEtmPmMaxRedFramesDropped
			INTEGER,
		genEquipPmRadioEthernetEtmPmAvgRedFramesDropped
			INTEGER,
		genEquipPmRadioEthernetEtmPmIDF
			Integrity,
		--genEquipPmRadioEthernetEtmPmMaxGreenBytesDropped
		--	INTEGER,
		--genEquipPmRadioEthernetEtmPmAvgGreenBytesDropped
		--	INTEGER,
		genEquipPmRadioEthernetEtmPmMaxGreenFramesPassed
			INTEGER,
		genEquipPmRadioEthernetEtmPmAvgGreenFramesPassed
			INTEGER,
		--genEquipPmRadioEthernetEtmPmMaxYellowBytesDropped
		--	INTEGER,
		--genEquipPmRadioEthernetEtmPmAvgYellowBytesDropped
		--	INTEGER,
		genEquipPmRadioEthernetEtmPmMaxYellowFramesPassed
			INTEGER,
		genEquipPmRadioEthernetEtmPmAvgYellowFramesPassed
			INTEGER,
		genEquipPmRadioEthernetEtmPmMaxRedBytesDropped
			INTEGER,
		genEquipPmRadioEthernetEtmPmAvgRedBytesDropped
			INTEGER
	}

genEquipPmRadioEthernetEtmPmType  OBJECT-TYPE
		SYNTAX  PmTableType
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmRadioEthernetEtmEntry 1 }

genEquipPmRadioEthernetEtmPmQueueIndex  OBJECT-TYPE
		SYNTAX  INTEGER (1..8)
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Queue index"
        ::= { genEquipPmRadioEthernetEtmEntry 2 }

genEquipPmRadioEthernetEtmInterval  OBJECT-TYPE
		SYNTAX  INTEGER (0..96)
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"The interval of the PM."
        ::= { genEquipPmRadioEthernetEtmEntry 3 }

genEquipPmRadioEthernetEtmPmMaxGreenBytesPassed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Maximum Green Traffic Passed Bytes."
        ::= { genEquipPmRadioEthernetEtmEntry 4 }

genEquipPmRadioEthernetEtmPmAvgGreenBytesPassed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Average Green Traffic Passed Bytes."
        ::= { genEquipPmRadioEthernetEtmEntry 5 }

genEquipPmRadioEthernetEtmPmMaxGreenFramesDropped  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Maximum Green Traffic Frames Droped by WRED."
        ::= { genEquipPmRadioEthernetEtmEntry 6 }

genEquipPmRadioEthernetEtmPmAvgGreenFramesDropped  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Average Green Traffic Frames Droped by WRED."
        ::= { genEquipPmRadioEthernetEtmEntry 7 }

genEquipPmRadioEthernetEtmPmMaxYellowBytesPassed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Maximum Yellow Traffic Passed Bytes."
        ::= { genEquipPmRadioEthernetEtmEntry 8 }

genEquipPmRadioEthernetEtmPmAvgYellowBytesPassed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Average Yellow Traffic Passed Bytes."
        ::= { genEquipPmRadioEthernetEtmEntry 9 }

genEquipPmRadioEthernetEtmPmMaxYellowFramesDropped  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Maximum Yellow Traffic Frames Droped by WRED."
        ::= { genEquipPmRadioEthernetEtmEntry 10 }

genEquipPmRadioEthernetEtmPmAvgYellowFramesDropped  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Average Yellow Traffic Frames Droped by WRED."
        ::= { genEquipPmRadioEthernetEtmEntry 11 }

genEquipPmRadioEthernetEtmPmMaxRedFramesDropped  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Maximum Red Traffic Frames Dropped."
        ::= { genEquipPmRadioEthernetEtmEntry 12 }

genEquipPmRadioEthernetEtmPmAvgRedFramesDropped  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Average Red Traffic Frames Dropped."
        ::= { genEquipPmRadioEthernetEtmEntry 13 }

genEquipPmRadioEthernetEtmPmIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmRadioEthernetEtmEntry 14 }

--genEquipPmRadioEthernetEtmPmMaxGreenBytesDropped  OBJECT-TYPE
--		SYNTAX  INTEGER
--        ACCESS  read-only
--        STATUS mandatory
--        DESCRIPTION
--		"Maximum Green Traffic Dropped Bytes."
--        ::= { genEquipPmRadioEthernetEtmEntry 15}

--genEquipPmRadioEthernetEtmPmAvgGreenBytesDropped  OBJECT-TYPE
--		SYNTAX  INTEGER
--        ACCESS  read-only
--        STATUS mandatory
--        DESCRIPTION
--		"Average Green Traffic Dropped Bytes."
--        ::= { genEquipPmRadioEthernetEtmEntry 16}

genEquipPmRadioEthernetEtmPmMaxGreenFramesPassed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Maximum Green Traffic Frames Passed."
        ::= { genEquipPmRadioEthernetEtmEntry 17}

genEquipPmRadioEthernetEtmPmAvgGreenFramesPassed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Average Green Traffic Frames Passed."
        ::= { genEquipPmRadioEthernetEtmEntry 18}

--genEquipPmRadioEthernetEtmPmMaxYellowBytesDropped  OBJECT-TYPE
--		SYNTAX  INTEGER
--        ACCESS  read-only
--        STATUS mandatory
--        DESCRIPTION
--		"Maximum Yellow Traffic Dropped Bytes."
--        ::= { genEquipPmRadioEthernetEtmEntry 19}

--genEquipPmRadioEthernetEtmPmAvgYellowBytesDropped  OBJECT-TYPE
--		SYNTAX  INTEGER
--        ACCESS  read-only
--        STATUS mandatory
--        DESCRIPTION
--		"Average Yellow Traffic Dropped Bytes."
--        ::= { genEquipPmRadioEthernetEtmEntry 20}

genEquipPmRadioEthernetEtmPmMaxYellowFramesPassed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Maximum Yellow Traffic Frames Passed."
        ::= { genEquipPmRadioEthernetEtmEntry 21}

genEquipPmRadioEthernetEtmPmAvgYellowFramesPassed  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Average Yellow Traffic Frames Passed."
        ::= { genEquipPmRadioEthernetEtmEntry 22}

genEquipPmRadioEthernetEtmPmMaxRedBytesDropped  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Maximum Red Traffic Bytes Dropped."
        ::= { genEquipPmRadioEthernetEtmEntry 23}

genEquipPmRadioEthernetEtmPmAvgRedBytesDropped  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Average Red Traffic Bytes Dropped."
        ::= { genEquipPmRadioEthernetEtmEntry 24}


--
genEquipPmRadioMSETable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRadioMSEEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "Radio MSE PM"
        ::= { genEquipPmRadio 4 }

genEquipPmRadioMSEEntry OBJECT-TYPE
        SYNTAX GenEquipPmRadioMSEEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Radio MSE PM"
        INDEX { genEquipPmRadioMSEPmType, ifIndex, genEquipPmRadioMSEInterval }
        ::= { genEquipPmRadioMSETable 1 }

GenEquipPmRadioMSEEntry ::=
            SEQUENCE {
		genEquipPmRadioMSEPmType		PmTableType,
		genEquipPmRadioMSEInterval		INTEGER,
        genEquipPmRadioMSEMinMse		INTEGER,
        genEquipPmRadioMSEMaxMse		INTEGER,
        genEquipPmRadioMSEexceeded		INTEGER,
        genEquipPmRadioMSEIDF		Integrity
	}

genEquipPmRadioMSEPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmRadioMSEEntry 1 }

genEquipPmRadioMSEInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM"
        ::= { genEquipPmRadioMSEEntry 2 }

genEquipPmRadioMSEMinMse OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This parameter holds the minimum MSE value detected in  the interval."
        ::= { genEquipPmRadioMSEEntry 3 }

genEquipPmRadioMSEMaxMse OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This parameter holds the maximum MSE value detected in  the interval."
        ::= { genEquipPmRadioMSEEntry 4 }

genEquipPmRadioMSEexceeded OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This parameter holds the number of seconds that the MSE exceeded the configured threshold."
        ::= { genEquipPmRadioMSEEntry 5 }

genEquipPmRadioMSEIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmRadioMSEEntry 6 }


--  Radio Thresold

genEquipPmRadioThresholdTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRadioThresholdEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "Radio MSE PM"
        ::= { genEquipPmRadio 5 }

genEquipPmRadioThresholdEntry OBJECT-TYPE
        SYNTAX GenEquipPmRadioThresholdEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Radio MSE PM"
        INDEX { genEquipRadioCfgRadioId }
        ::= { genEquipPmRadioThresholdTable 1 }

GenEquipPmRadioThresholdEntry ::=
            SEQUENCE {
		genEquipPmRadioThresholdMSE		INTEGER,
		genEquipPmRadioThresholdRSL1	INTEGER,
        genEquipPmRadioThresholdRSL2 	INTEGER,
        genEquipPmRadioThresholdTSL		INTEGER,
        genEquipPmRadioThresholdXPI		INTEGER
	}

genEquipPmRadioThresholdMSE OBJECT-TYPE
        SYNTAX  INTEGER (-99..-1)
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "The threshold above which MSE (Mean Square Error) exceeded seconds will be counted"
        ::= { genEquipPmRadioThresholdEntry 1 }

genEquipPmRadioThresholdRSL1 OBJECT-TYPE
        SYNTAX  INTEGER (-75..-15)
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "The threshold below which RSL 1 exceeded seconds will be counted"
        ::= { genEquipPmRadioThresholdEntry 2 }

genEquipPmRadioThresholdRSL2 OBJECT-TYPE
        SYNTAX  INTEGER (-75..-15)
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "The threshold below which RSL 2 exceeded seconds will be counted"
        ::= { genEquipPmRadioThresholdEntry 3 }

genEquipPmRadioThresholdTSL OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "The threshold above which TSL exceeded seconds will be counted"
        ::= { genEquipPmRadioThresholdEntry 4 }

genEquipPmRadioThresholdXPI OBJECT-TYPE
        SYNTAX  INTEGER (0..99)
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "The threshold above which XPI (Cross Polar Interference) exceeded seconds will be counted"
        ::= { genEquipPmRadioThresholdEntry 5 }


--  Radio XPIC

genEquipPmRadioXPITable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmRadioXPIEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "Radio XPIC PM"
        ::= { genEquipPmRadio 6 }

genEquipPmRadioXPIEntry OBJECT-TYPE
        SYNTAX GenEquipPmRadioXPIEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Radio XPIC PM"
        INDEX { genEquipPmRadioXPIPmType, ifIndex, genEquipPmRadioXPIPmInterval }
        ::= { genEquipPmRadioXPITable 1 }

GenEquipPmRadioXPIEntry ::=
            SEQUENCE {
		genEquipPmRadioXPIPmType			PmTableType,
		genEquipPmRadioXPIPmInterval		INTEGER,
        genEquipPmRadioXPIPmMinXPI 			INTEGER,
        genEquipPmRadioXPIPmMaxXPI			INTEGER,
		genEquipPmRadioXPIBelowThreshold	INTEGER,
        genEquipPmRadioXPIIDF		Integrity
	}

genEquipPmRadioXPIPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM"
        ::= { genEquipPmRadioXPIEntry 1 }

genEquipPmRadioXPIPmInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The number of the interval: 1-30 in case the interval is 24 hours or 1-900 in case the interval is 15 minutes"
        ::= { genEquipPmRadioXPIEntry 2 }

genEquipPmRadioXPIPmMinXPI OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This parameter holds the minimum XPI value detected in the interval"
        ::= { genEquipPmRadioXPIEntry 3 }

genEquipPmRadioXPIPmMaxXPI OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This parameter holds the maximum XPI value detected in the interval"
        ::= { genEquipPmRadioXPIEntry 4 }

genEquipPmRadioXPIBelowThreshold OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This parameter holds the number of seconds in the interval that the XPI value was below the configured threshold."
        ::= { genEquipPmRadioXPIEntry 5 }

genEquipPmRadioXPIIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmRadioXPIEntry 6 }


--  Clear RAdio PM

genEquipPmRadioClear  OBJECT-TYPE
		SYNTAX  OffOn
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"Clear all radio PMs (Performance Monitoring)."
        ::= { genEquipPmRadio 7 }


-- 	TDM (E1/T1) PM Group
genEquipPmTDM	OBJECT IDENTIFIER ::= {genEquipPmAll 5}

-- 	TDM (E1/T1) PM Table
genEquipPmTdmTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmTdmEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The line TDM PM table"
        ::= { genEquipPmTDM 1 }

genEquipPmTdmEntry OBJECT-TYPE
        SYNTAX GenEquipPmTdmEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The line TDM PM table"
        INDEX { genEquipPmTdmPmType, ifIndex, genEquipPmTdmInterval }
        ::= { genEquipPmTdmTable 1 }

GenEquipPmTdmEntry ::=
            SEQUENCE {
		genEquipPmTdmPmType				PmTableType,
		genEquipPmTdmInterval			INTEGER,
        genEquipPmTdmES					INTEGER,
        genEquipPmTdmSES				INTEGER,
        genEquipPmTdmUAS				INTEGER,
        genEquipPmTdmBBE				INTEGER,
        genEquipPmTdmIDF				Integrity
	}

genEquipPmTdmPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmTdmEntry 1 }

genEquipPmTdmInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM"
        ::= { genEquipPmTdmEntry 2 }

genEquipPmTdmES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"ES PM (Errored second)"
		::= { genEquipPmTdmEntry 3 }

genEquipPmTdmSES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"SES PM (Severe Errored Seconds)"
		::= { genEquipPmTdmEntry 4 }

genEquipPmTdmUAS	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"UAS PM (Unavailable Seconds)."
		::= { genEquipPmTdmEntry 5 }

genEquipPmTdmBBE	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"BBE PM (Background Block Errors)"
		::= { genEquipPmTdmEntry 6 }

genEquipPmTdmIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmTdmEntry 7 }

-- 	SDH/Sonet PM Group
genEquipPmSDH	OBJECT IDENTIFIER ::= {genEquipPmAll 6}

genEquipPmSdhTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmSdhEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The line SDH PM table."
        ::= { genEquipPmSDH 1 }

genEquipPmSdhEntry OBJECT-TYPE
        SYNTAX GenEquipPmSdhEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The line SDH PM table."
        INDEX { genEquipPmSdhPmType, ifIndex, genEquipPmSdhInterval }
        ::= { genEquipPmSdhTable 1 }

GenEquipPmSdhEntry ::=
            SEQUENCE {
		genEquipPmSdhPmType				PmTableType,
		genEquipPmSdhInterval			INTEGER,
        genEquipPmSdhES					INTEGER,
        genEquipPmSdhSES				INTEGER,
        genEquipPmSdhEB					INTEGER,
        genEquipPmSdhBBE				INTEGER,
        genEquipPmSdhIDF				Integrity,
		genEquipPmSdhIfIndex			INTEGER,
		genEquipPmSdhTimeStamp			INTEGER,
		genEquipPmSdhUAS				INTEGER
	}

genEquipPmSdhPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
        ::= { genEquipPmSdhEntry 1 }

genEquipPmSdhInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM."
        ::= { genEquipPmSdhEntry 2 }

genEquipPmSdhES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"ES STM-1/OC-3 PM."
		::= { genEquipPmSdhEntry 3 }

genEquipPmSdhSES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"SES STM-1/OC-3 PM."
		::= { genEquipPmSdhEntry 4 }

genEquipPmSdhEB	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"EB STM-1/OC-3 PM (Errored block)."
		::= { genEquipPmSdhEntry 5 }

genEquipPmSdhBBE	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"BBE PM (background errored block STM-1/OC-3 PM or CVL PM (code violation line) when using OC-3."
		::= { genEquipPmSdhEntry 6 }

genEquipPmSdhIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmSdhEntry 7 }

genEquipPmSdhIfIndex  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Port Number."
        ::= { genEquipPmSdhEntry 8 }

genEquipPmSdhTimeStamp  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates the time stamp of the interval."
        ::= { genEquipPmSdhEntry 9 }

genEquipPmSdhUAS  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Un-Available Seconds STM-1/OC-3 PM."
        ::= { genEquipPmSdhEntry 10 }

-- SONET/STM-1 interface-level PMs for line to radio direction - rst-stm1oc3-pm-status-ltor-table
--

genEquipPmSdhRstLRTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmSdhRstLREntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "SONET/STM-1 interface-level PMs for line to radio direction."
        ::= { genEquipPmSDH 2 }

genEquipPmSdhRstLREntry OBJECT-TYPE
        SYNTAX GenEquipPmSdhRstLREntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "SONET/STM-1 interface-level PMs for line to radio direction entry."
        INDEX { genEquipPmSdhRstLRPmType,
				genEquipPmSdhRstLRIfIndex,
				genEquipPmSdhRstLRInterval }
        ::= { genEquipPmSdhRstLRTable 1 }

GenEquipPmSdhRstLREntry ::=
            SEQUENCE {
		genEquipPmSdhRstLRPmType				PmTableType,
		genEquipPmSdhRstLRIfIndex				INTEGER,
		genEquipPmSdhRstLRInterval				INTEGER,
        genEquipPmSdhRstLRTimeStamp				INTEGER,
        genEquipPmSdhRstLRES					INTEGER,
        genEquipPmSdhRstLRSES					INTEGER,
        genEquipPmSdhRstLRUAS					INTEGER,
        genEquipPmSdhRstLREB					INTEGER,
		genEquipPmSdhRstLRCV					INTEGER,
		genEquipPmSdhRstLRBBE					INTEGER,
		genEquipPmSdhRstLRIDF					Integrity
	}

genEquipPmSdhRstLRPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
        ::= { genEquipPmSdhRstLREntry 1 }

genEquipPmSdhRstLRIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Port number."
        ::= { genEquipPmSdhRstLREntry 2 }

genEquipPmSdhRstLRInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM."
        ::= { genEquipPmSdhRstLREntry 3 }

genEquipPmSdhRstLRTimeStamp	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the time stamp of the interval."
		::= { genEquipPmSdhRstLREntry 4 }

genEquipPmSdhRstLRES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Errored Seconds PM for STM-1/OC-3 on line to radio direction."
		::= { genEquipPmSdhRstLREntry 5 }

genEquipPmSdhRstLRSES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Severely Errored Seconds PM for STM-1/OC-3 on line to radio direction."
		::= { genEquipPmSdhRstLREntry 6 }

genEquipPmSdhRstLRUAS	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Unavailable Seconds PM for STM-1/OC-3."
		::= { genEquipPmSdhRstLREntry 7 }

genEquipPmSdhRstLREB  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Errored Blocks PM for STM-1/OC-3 on line to radio direction."
        ::= { genEquipPmSdhRstLREntry 8 }

genEquipPmSdhRstLRCV  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Code Viloations PM for STM-1/OC-3 on line to radio direction."
        ::= { genEquipPmSdhRstLREntry 9 }

genEquipPmSdhRstLRBBE  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Background Block Error PM for STM-1/OC-3 on line to radio direction."
        ::= { genEquipPmSdhRstLREntry 10 }

genEquipPmSdhRstLRIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmSdhRstLREntry 11 }


-- SONET/STM-1 interface-level PMs for radio to line direction - rst-stm1oc3-pm-status-crl-type
--

genEquipPmSdhRstRLTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmSdhRstRLEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "SONET/STM-1 interface-level PMs for radio to line direction."
        ::= { genEquipPmSDH 3 }

genEquipPmSdhRstRLEntry OBJECT-TYPE
        SYNTAX GenEquipPmSdhRstRLEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "SONET/STM-1 interface-level PMs for radio to line direction entry."
        INDEX { genEquipPmSdhRstRLPmType,
				genEquipPmSdhRstRLIfIndex,
				genEquipPmSdhRstRLInterval }
        ::= { genEquipPmSdhRstRLTable 1 }

GenEquipPmSdhRstRLEntry ::=
            SEQUENCE {
		genEquipPmSdhRstRLPmType				PmTableType,
		genEquipPmSdhRstRLIfIndex				INTEGER,
		genEquipPmSdhRstRLInterval				INTEGER,
        genEquipPmSdhRstRLTimeStamp				INTEGER,
        genEquipPmSdhRstRLES					INTEGER,
        genEquipPmSdhRstRLSES					INTEGER,
        genEquipPmSdhRstRLUAS					INTEGER,
        genEquipPmSdhRstRLEB					INTEGER,
		genEquipPmSdhRstRLCV					INTEGER,
		genEquipPmSdhRstRLBBE					INTEGER,
		genEquipPmSdhRstRLIDF					Integrity
	}

genEquipPmSdhRstRLPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
        ::= { genEquipPmSdhRstRLEntry 1 }

genEquipPmSdhRstRLIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Port number."
        ::= { genEquipPmSdhRstRLEntry 2 }

genEquipPmSdhRstRLInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM."
        ::= { genEquipPmSdhRstRLEntry 3 }

genEquipPmSdhRstRLTimeStamp	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"This value indicates the time stamp of the interval."
		::= { genEquipPmSdhRstRLEntry 4 }

genEquipPmSdhRstRLES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Errored Seconds PM for STM-1/OC-3 on radio to line direction."
		::= { genEquipPmSdhRstRLEntry 5 }

genEquipPmSdhRstRLSES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Severely Errored Seconds PM for STM-1/OC-3 on radio to line direction."
		::= { genEquipPmSdhRstRLEntry 6 }

genEquipPmSdhRstRLUAS	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Unavailable Seconds PM for STM-1/OC-3."
		::= { genEquipPmSdhRstRLEntry 7 }

genEquipPmSdhRstRLEB  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Errored Blocks PM for STM-1/OC-3 on radio to line direction."
        ::= { genEquipPmSdhRstRLEntry 8 }

genEquipPmSdhRstRLCV  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Code Viloations PM for STM-1/OC-3 on radio to line direction."
        ::= { genEquipPmSdhRstRLEntry 9 }

genEquipPmSdhRstRLBBE  OBJECT-TYPE
		SYNTAX  INTEGER
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"Background Block Error PM for STM-1/OC-3 on radio to line direction."
        ::= { genEquipPmSdhRstRLEntry 10 }

genEquipPmSdhRstRLIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmSdhRstRLEntry 11 }


-- 	Trails PM Group
genEquipPmTrails	OBJECT IDENTIFIER ::= {genEquipPmAll 7}

-- 	TDM (E1/T1) PM Table
genEquipPmTrailsEndPointTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmTrailsEndPointEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "PM table of the E1/T1 trails."
        ::= { genEquipPmTrails 1 }

genEquipPmTrailsEndPointEntry OBJECT-TYPE
        SYNTAX GenEquipPmTrailsEndPointEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "PM table of the E1/T1 trails."
        INDEX { genEquipPmTrailsEndPointPmType, genEquipPmTrailsEndPointId, genEquipPmTrailsEndPointEPId, genEquipPmTrailsEndPointInterval }
        ::= { genEquipPmTrailsEndPointTable 1 }

GenEquipPmTrailsEndPointEntry ::=
            SEQUENCE {
		genEquipPmTrailsEndPointPmType					PmTableType,
		genEquipPmTrailsEndPointId						DisplayString,
		genEquipPmTrailsEndPointEPId					INTEGER,
		genEquipPmTrailsEndPointInterval				INTEGER,
        genEquipPmTrailsEndPointES						INTEGER,
        genEquipPmTrailsEndPointSES						INTEGER,
        genEquipPmTrailsEndPointUAS						INTEGER,
        genEquipPmTrailsEndPointBBE						INTEGER,
        genEquipPmTrailsEndPointNoOfSwitches			INTEGER,
        genEquipPmTrailsEndPointActivePathCounts		INTEGER,
        genEquipPmTrailsEndPointIDF						Integrity
	}

genEquipPmTrailsEndPointPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
        ::= { genEquipPmTrailsEndPointEntry 1 }

genEquipPmTrailsEndPointId OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the trail id."
        ::= { genEquipPmTrailsEndPointEntry 2 }

genEquipPmTrailsEndPointEPId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the end point number for this trail.
        If the trail is protected, there will be two end points for the trail (primary path and the secondary path)."
        ::= { genEquipPmTrailsEndPointEntry 3 }

genEquipPmTrailsEndPointInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM."
        ::= { genEquipPmTrailsEndPointEntry 4 }

genEquipPmTrailsEndPointES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"ES PM (Errored Seconds)."
		::= { genEquipPmTrailsEndPointEntry 5 }

genEquipPmTrailsEndPointSES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"SES PM (Severe Errored Seconds)."
		::= { genEquipPmTrailsEndPointEntry 6 }

genEquipPmTrailsEndPointUAS	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"UAS PM (Unavailable Seconds)."
		::= { genEquipPmTrailsEndPointEntry 7 }

genEquipPmTrailsEndPointBBE	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"BBE PM (Background Block Errors)."
		::= { genEquipPmTrailsEndPointEntry 8 }

genEquipPmTrailsEndPointNoOfSwitches	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"A counter of the number of SNCP switches (between primary and secondary paths) that trail had in the relevant interval."
		::= { genEquipPmTrailsEndPointEntry 9 }

genEquipPmTrailsEndPointActivePathCounts	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Active path seconds. "
		::= { genEquipPmTrailsEndPointEntry 10 }

genEquipPmTrailsEndPointIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmTrailsEndPointEntry 11 }

-- 	PW PM Group
genEquipPmPW	OBJECT IDENTIFIER ::= {genEquipPmAll 8}

-- 	TDM (E1/T1) PM Table
genEquipPmPWTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmPWEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table shows standard pseudowire-level PM measurements. Notice that PMs at the TDM port level are maintained separately."
        ::= { genEquipPmPW 1 }

genEquipPmPWEntry OBJECT-TYPE
        SYNTAX GenEquipPmPWEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table shows standard pseudowire-level PM measurements. Notice that PMs at the TDM port level are maintained separately."
        INDEX { genEquipPmPWPmType, genEquipPmPWId, genEquipPmPWInterval }
        ::= { genEquipPmPWTable 1 }

GenEquipPmPWEntry ::=
            SEQUENCE {
		genEquipPmPWPmType
			PmTableType,
		genEquipPmPWId
			INTEGER,
		genEquipPmPWInterval
			INTEGER,
        genEquipPmPWMissingPkts
			INTEGER,
        genEquipPmPWPktsReOrder
			INTEGER,
        genEquipPmPWtrBfrUnderruns
			INTEGER,
        genEquipPmPWMisOrderDropped
			INTEGER,
        genEquipPmPWMalformedPkt
			INTEGER,
		genEquipPmPWES
			INTEGER,
        genEquipPmPWSES
			INTEGER,
        genEquipPmPWUAS
			INTEGER,
        genEquipPmPWFC
			INTEGER,
        genEquipPmPWIDF
			Integrity
	}

genEquipPmPWPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
        ::= { genEquipPmPWEntry 1 }

genEquipPmPWId OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the trail id."
        ::= { genEquipPmPWEntry 2 }


genEquipPmPWInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM."
        ::= { genEquipPmPWEntry 3 }

genEquipPmPWMissingPkts	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of missing packets (as detected via control word sequence number gaps)."
		::= { genEquipPmPWEntry 4 }

genEquipPmPWPktsReOrder	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of packets detected out of sequence (via control word sequence number) but successfully re-ordered."
		::= { genEquipPmPWEntry 5 }

genEquipPmPWtrBfrUnderruns	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of times a packet needed to be played out and the jitter buffer was empty."
		::= { genEquipPmPWEntry 6 }

genEquipPmPWMisOrderDropped	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of packets detected out of order (via control word sequence numbers) that could not be re-ordered or could
		not fit in the jitter buffer."
		::= { genEquipPmPWEntry 7 }

genEquipPmPWMalformedPkt	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of packets detected with unexpected size, or bad headers' stack."
		::= { genEquipPmPWEntry 8 }

genEquipPmPWES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"ES PM (Errored Seconds)."
		::= { genEquipPmPWEntry 9 }

genEquipPmPWSES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"SES PM (Severe Errored Seconds)."
		::= { genEquipPmPWEntry 10 }

genEquipPmPWUAS	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"UAS PM (Unavailable Seconds)."
		::= { genEquipPmPWEntry 11 }

genEquipPmPWFC	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"FC (Failure Counts) PM. A failure is a LOPS event."
		::= { genEquipPmPWEntry 12 }

genEquipPmPWIDF  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmPWEntry 13 }

--
-- 	PW service PMs table - pw-service-pm-status-table
--

genEquipPmNGPWTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmNGPWEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "This table contains PW Performance Monitoring counters."
        ::= { genEquipPmPW 2 }

genEquipPmNGPWEntry OBJECT-TYPE
        SYNTAX GenEquipPmNGPWEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "This table entry contains PW Performance Monitoring counters."
        INDEX { genEquipPmNGPWPmType, genEquipPmNGPWIfIndex, genEquipPmNGPWInterval }
        ::= { genEquipPmNGPWTable 1 }

GenEquipPmNGPWEntry ::=
            SEQUENCE {
		genEquipPmNGPWPmType
			PmTableType,
		genEquipPmNGPWIfIndex
			INTEGER,
		genEquipPmNGPWInterval
			INTEGER,
        genEquipPmNGPWES
			INTEGER,
        genEquipPmNGPWSES
			INTEGER,
        genEquipPmNGPWUAS
			INTEGER,
        genEquipPmNGPWFC
			INTEGER,
        genEquipPmNGPWFER
			INTEGER,
		genEquipPmNGPWMissingPkts
			INTEGER,
        genEquipPmNGPWPktsReOrder
			INTEGER,
        genEquipPmNGPWMisOrderDropped
			INTEGER,
        genEquipPmNGPWMalformedPkt
			INTEGER,
        genEquipPmNGPWIdf
			Integrity
	}

genEquipPmNGPWPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours."
        ::= { genEquipPmNGPWEntry 1 }

genEquipPmNGPWIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the interface Index."
        ::= { genEquipPmNGPWEntry 2 }


genEquipPmNGPWInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM."
        ::= { genEquipPmNGPWEntry 3 }

genEquipPmNGPWES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"ES (Errored Seconds) PM."
		::= { genEquipPmNGPWEntry 4 }

genEquipPmNGPWSES	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"SES (Severe Errored Seconds) PM."
		::= { genEquipPmNGPWEntry 5 }

genEquipPmNGPWUAS	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"UAS (Unavailable Seconds) PM."
		::= { genEquipPmNGPWEntry 6 }

genEquipPmNGPWFC	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"FC (Failure Counts) PM. A failure is a LOPS event."
		::= { genEquipPmNGPWEntry 7 }

genEquipPmNGPWFER	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Frame Error Ratio."
		::= { genEquipPmNGPWEntry 8 }

genEquipPmNGPWMissingPkts	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of missing packets (as detected via control word sequence number gaps)."
		::= { genEquipPmNGPWEntry 9 }

genEquipPmNGPWPktsReOrder	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of packets detected out of sequence (via control word sequence number) but successfully re-ordered."
		::= { genEquipPmNGPWEntry 10 }

genEquipPmNGPWMisOrderDropped	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of packets detected out of order (via control word sequence numbers) that could not be re-ordered or could not fit in the jitter buffer."
		::= { genEquipPmNGPWEntry 11 }

genEquipPmNGPWMalformedPkt	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of packets detected with unexpected size, or bad headers' stack."
		::= { genEquipPmNGPWEntry 12 }

genEquipPmNGPWIdf  OBJECT-TYPE
		SYNTAX  Integrity
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
        ::= { genEquipPmNGPWEntry 13 }


-- PM Utilization
genEquipPmEthUtilization	OBJECT IDENTIFIER ::= {genEquipPmAll 9}

genEquipPmEthUtilizationAdmin  OBJECT-TYPE
		SYNTAX  EnableDisable
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"Ethernet port utilization PM admin"
        ::= { genEquipPmEthUtilization 1 }

genEquipPmEthUtilizationThreshold  OBJECT-TYPE
		SYNTAX  INTEGER (0..100)
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"User defined threshold for Ethernet port utilization PM."
        ::= { genEquipPmEthUtilization 2 }

genEquipPmEthUtilizationTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthUtilizationEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The Ethernet ports Utilization PMs"
        ::= { genEquipPmEthUtilization 3 }

genEquipPmEthUtilizationEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthUtilizationEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The Ethernet ports Utilization PMs"
        INDEX { genEquipPmEthUtilizationPmType, ifIndex, genEquipPmEthUtilizationInterval }
        ::= { genEquipPmEthUtilizationTable 1 }

GenEquipPmEthUtilizationEntry ::=
            SEQUENCE {
		genEquipPmEthUtilizationPmType				PmTableType,
		genEquipPmEthUtilizationInterval			INTEGER,
		genEquipPmEthUtilizationPeakUtilization		INTEGER,
		genEquipPmEthUtilizationAverageUtilization	INTEGER,
		genEquipPmEthUtilizationExceedUtilization	INTEGER,
        genEquipPmEthUtilizationIDF					Integrity
	}

genEquipPmEthUtilizationPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmEthUtilizationEntry 1 }

genEquipPmEthUtilizationInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM"
        ::= { genEquipPmEthUtilizationEntry 2 }

genEquipPmEthUtilizationPeakUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Peak Ethernet port utilization of the current interval."
		::= { genEquipPmEthUtilizationEntry 3 }

genEquipPmEthUtilizationAverageUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Average Ethernet port utilization of the current interval."
		::= { genEquipPmEthUtilizationEntry 4 }

genEquipPmEthUtilizationExceedUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of seconds in current interval when Ethernet port utilization exceeded the user defined threshold."
		::= { genEquipPmEthUtilizationEntry 5 }

genEquipPmEthUtilizationIDF  OBJECT-TYPE
		SYNTAX  Integrity
		ACCESS  read-only
		STATUS mandatory
		DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
		::= { genEquipPmEthUtilizationEntry 6 }


-- PM Utilization
genEquipPmEthernetIngressPolicer	OBJECT IDENTIFIER ::= {genEquipPmAll 10}

--
-- Logical Port unicast policer statistics - sw-ap-l2-if-logical-ingress-policer1-unicast-statistics-table
--

genEquipPmEthernetIngressPolicerUnicastStatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthernetIngressPolicerUnicastStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "logical Interface unicast policer statistics."
        ::= { genEquipPmEthernetIngressPolicer 1 }

genEquipPmEthernetIngressPolicerUnicastStatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthernetIngressPolicerUnicastStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "logical Interface unicast policer statistics."
        INDEX { genEquipPmEthernetIngressPolicerUnicastStatisticsIfIndex }
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsTable 1 }

GenEquipPmEthernetIngressPolicerUnicastStatisticsEntry ::=
	SEQUENCE {
		genEquipPmEthernetIngressPolicerUnicastStatisticsIfIndex
			INTEGER,
		genEquipPmEthernetIngressPolicerUnicastStatisticsClearOnRead
			NoYes,
	    genEquipPmEthernetIngressPolicerUnicastStatisticsGreenPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerUnicastStatisticsGreenBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerUnicastStatisticsYellowPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerUnicastStatisticsYellowBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerUnicastStatisticsRedPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerUnicastStatisticsRedBytes
			Counter64
	}

genEquipPmEthernetIngressPolicerUnicastStatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Ethernet Logical port if-index table key"
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 1 }

genEquipPmEthernetIngressPolicerUnicastStatisticsClearOnRead  OBJECT-TYPE
        SYNTAX 	NoYes
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
        "Clear counter statistics after reading."
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 2 }

genEquipPmEthernetIngressPolicerUnicastStatisticsGreenPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 3 }

genEquipPmEthernetIngressPolicerUnicastStatisticsGreenBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 4 }

genEquipPmEthernetIngressPolicerUnicastStatisticsYellowPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 5 }

genEquipPmEthernetIngressPolicerUnicastStatisticsYellowBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 6 }

genEquipPmEthernetIngressPolicerUnicastStatisticsRedPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 7 }

genEquipPmEthernetIngressPolicerUnicastStatisticsRedBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerUnicastStatisticsEntry 8 }

--
-- Logical Port unicast policer statistics - sw-ap-l2-if-logical-ingress-policer2-multicast-statistics-table
--

genEquipPmEthernetIngressPolicerMulticastStatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthernetIngressPolicerMulticastStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Logical Port multicast policer statistics."
        ::= { genEquipPmEthernetIngressPolicer 2 }

genEquipPmEthernetIngressPolicerMulticastStatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthernetIngressPolicerMulticastStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Logical Port multicast policer statistics."
        INDEX { genEquipPmEthernetIngressPolicerMulticastStatisticsIfIndex }
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsTable 1 }

GenEquipPmEthernetIngressPolicerMulticastStatisticsEntry ::=
	SEQUENCE {
		genEquipPmEthernetIngressPolicerMulticastStatisticsIfIndex
			INTEGER,
		genEquipPmEthernetIngressPolicerMulticastStatisticsClearOnRead
			NoYes,
	    genEquipPmEthernetIngressPolicerMulticastStatisticsGreenPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerMulticastStatisticsGreenBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerMulticastStatisticsYellowPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerMulticastStatisticsYellowBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerMulticastStatisticsRedPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerMulticastStatisticsRedBytes
			Counter64
	}

genEquipPmEthernetIngressPolicerMulticastStatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Ethernet Logical port if-index table key"
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 1 }

genEquipPmEthernetIngressPolicerMulticastStatisticsClearOnRead  OBJECT-TYPE
        SYNTAX 	NoYes
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
        "Clear counter statistics after reading."
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 2 }

genEquipPmEthernetIngressPolicerMulticastStatisticsGreenPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 3 }

genEquipPmEthernetIngressPolicerMulticastStatisticsGreenBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 4 }

genEquipPmEthernetIngressPolicerMulticastStatisticsYellowPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 5 }

genEquipPmEthernetIngressPolicerMulticastStatisticsYellowBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 6 }

genEquipPmEthernetIngressPolicerMulticastStatisticsRedPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 7 }

genEquipPmEthernetIngressPolicerMulticastStatisticsRedBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerMulticastStatisticsEntry 8 }

--
-- Logical Port broadcast policer statistics - sw-ap-l2-if-logical-ingress-policer3-broadcast-statistics-table
--

genEquipPmEthernetIngressPolicerBroadcastStatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthernetIngressPolicerBroadcastStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface Logical Port broadcast policer statistics."
        ::= { genEquipPmEthernetIngressPolicer 3 }

genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthernetIngressPolicerBroadcastStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface Logical Port broadcast policer statistics."
        INDEX { genEquipPmEthernetIngressPolicerBroadcastStatisticsIfIndex }
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsTable 1 }

GenEquipPmEthernetIngressPolicerBroadcastStatisticsEntry ::=
	SEQUENCE {
		genEquipPmEthernetIngressPolicerBroadcastStatisticsIfIndex
			INTEGER,
		genEquipPmEthernetIngressPolicerBroadcastStatisticsClearOnRead
			NoYes,
	    genEquipPmEthernetIngressPolicerBroadcastStatisticsGreenPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerBroadcastStatisticsGreenBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerBroadcastStatisticsYellowPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerBroadcastStatisticsYellowBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerBroadcastStatisticsRedPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerBroadcastStatisticsRedBytes
			Counter64
	}

genEquipPmEthernetIngressPolicerBroadcastStatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Ethernet Logical port if-index table key"
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 1 }

genEquipPmEthernetIngressPolicerBroadcastStatisticsClearOnRead  OBJECT-TYPE
        SYNTAX 	NoYes
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
        "Clear counter statistics after reading."
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 2 }

genEquipPmEthernetIngressPolicerBroadcastStatisticsGreenPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 3 }

genEquipPmEthernetIngressPolicerBroadcastStatisticsGreenBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 4 }

genEquipPmEthernetIngressPolicerBroadcastStatisticsYellowPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 5 }

genEquipPmEthernetIngressPolicerBroadcastStatisticsYellowBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 6 }

genEquipPmEthernetIngressPolicerBroadcastStatisticsRedPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 7 }

genEquipPmEthernetIngressPolicerBroadcastStatisticsRedBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerBroadcastStatisticsEntry 8 }

--
-- Logical Port ether Type 1 policer statistics - sw-ap-l2-if-logical-ingress-policer4-eth-type1-statistics-table
--

genEquipPmEthernetIngressPolicerEtherType1StatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthernetIngressPolicerEtherType1StatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface Logical Port ether Type 1 policer statistics."
        ::= { genEquipPmEthernetIngressPolicer 4 }

genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthernetIngressPolicerEtherType1StatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface Logical Port ether Type 1 policer statistics."
        INDEX { genEquipPmEthernetIngressPolicerEtherType1StatisticsIfIndex }
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsTable 1 }

GenEquipPmEthernetIngressPolicerEtherType1StatisticsEntry ::=
	SEQUENCE {
		genEquipPmEthernetIngressPolicerEtherType1StatisticsIfIndex
			INTEGER,
		genEquipPmEthernetIngressPolicerEtherType1StatisticsClearOnRead
			NoYes,
	    genEquipPmEthernetIngressPolicerEtherType1StatisticsGreenPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType1StatisticsGreenBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType1StatisticsYellowPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType1StatisticsYellowBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType1StatisticsRedPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType1StatisticsRedBytes
			Counter64
	}

genEquipPmEthernetIngressPolicerEtherType1StatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Ethernet Logical port if-index table key"
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 1 }

genEquipPmEthernetIngressPolicerEtherType1StatisticsClearOnRead  OBJECT-TYPE
        SYNTAX 	NoYes
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
        "Clear counter statistics after reading."
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 2 }

genEquipPmEthernetIngressPolicerEtherType1StatisticsGreenPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 3 }

genEquipPmEthernetIngressPolicerEtherType1StatisticsGreenBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 4 }

genEquipPmEthernetIngressPolicerEtherType1StatisticsYellowPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 5 }

genEquipPmEthernetIngressPolicerEtherType1StatisticsYellowBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 6 }

genEquipPmEthernetIngressPolicerEtherType1StatisticsRedPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 7 }

genEquipPmEthernetIngressPolicerEtherType1StatisticsRedBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerEtherType1StatisticsEntry 8 }

--
-- Logical Port ether Type 2 policer statistics - sw-ap-l2-if-logical-ingress-policer5-eth-type2-statistics-table
--

genEquipPmEthernetIngressPolicerEtherType2StatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthernetIngressPolicerEtherType2StatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface Logical Port ether Type 2 policer statistics."
        ::= { genEquipPmEthernetIngressPolicer 5 }

genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthernetIngressPolicerEtherType2StatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface Logical Port ether Type 2 policer statistics."
        INDEX { genEquipPmEthernetIngressPolicerEtherType2StatisticsIfIndex }
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsTable 1 }

GenEquipPmEthernetIngressPolicerEtherType2StatisticsEntry ::=
	SEQUENCE {
		genEquipPmEthernetIngressPolicerEtherType2StatisticsIfIndex
			INTEGER,
		genEquipPmEthernetIngressPolicerEtherType2StatisticsClearOnRead
			NoYes,
	    genEquipPmEthernetIngressPolicerEtherType2StatisticsGreenPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType2StatisticsGreenBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType2StatisticsYellowPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType2StatisticsYellowBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType2StatisticsRedPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType2StatisticsRedBytes
			Counter64
	}

genEquipPmEthernetIngressPolicerEtherType2StatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Ethernet Logical port if-index table key"
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 1 }

genEquipPmEthernetIngressPolicerEtherType2StatisticsClearOnRead  OBJECT-TYPE
        SYNTAX 	NoYes
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
        "Clear counter statistics after reading."
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 2 }

genEquipPmEthernetIngressPolicerEtherType2StatisticsGreenPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 3 }

genEquipPmEthernetIngressPolicerEtherType2StatisticsGreenBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 4 }

genEquipPmEthernetIngressPolicerEtherType2StatisticsYellowPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 5 }

genEquipPmEthernetIngressPolicerEtherType2StatisticsYellowBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 6 }

genEquipPmEthernetIngressPolicerEtherType2StatisticsRedPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 7 }

genEquipPmEthernetIngressPolicerEtherType2StatisticsRedBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerEtherType2StatisticsEntry 8 }

--
-- Logical Port ether Type 3 policer statistics - sw-ap-l2-if-logical-ingress-policer6-eth-type3-statistics-table
--

genEquipPmEthernetIngressPolicerEtherType3StatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthernetIngressPolicerEtherType3StatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface Logical Port ether Type 3 policer statistics."
        ::= { genEquipPmEthernetIngressPolicer 6 }

genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthernetIngressPolicerEtherType3StatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface Logical Port ether Type 3 policer statistics."
        INDEX { genEquipPmEthernetIngressPolicerEtherType3StatisticsIfIndex }
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsTable 1 }

GenEquipPmEthernetIngressPolicerEtherType3StatisticsEntry ::=
	SEQUENCE {
		genEquipPmEthernetIngressPolicerEtherType3StatisticsIfIndex
			INTEGER,
		genEquipPmEthernetIngressPolicerEtherType3StatisticsClearOnRead
			NoYes,
	    genEquipPmEthernetIngressPolicerEtherType3StatisticsGreenPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType3StatisticsGreenBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType3StatisticsYellowPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType3StatisticsYellowBytes
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType3StatisticsRedPacket
			Counter64,
	    genEquipPmEthernetIngressPolicerEtherType3StatisticsRedBytes
			Counter64
	}

genEquipPmEthernetIngressPolicerEtherType3StatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Ethernet Logical port if-index table key"
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 1 }

genEquipPmEthernetIngressPolicerEtherType3StatisticsClearOnRead  OBJECT-TYPE
        SYNTAX 	NoYes
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
        "Clear counter statistics after reading."
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 2 }

genEquipPmEthernetIngressPolicerEtherType3StatisticsGreenPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 3 }

genEquipPmEthernetIngressPolicerEtherType3StatisticsGreenBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as green."
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 4 }

genEquipPmEthernetIngressPolicerEtherType3StatisticsYellowPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 5 }

genEquipPmEthernetIngressPolicerEtherType3StatisticsYellowBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as yellow."
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 6 }

genEquipPmEthernetIngressPolicerEtherType3StatisticsRedPacket  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of packets that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 7 }

genEquipPmEthernetIngressPolicerEtherType3StatisticsRedBytes  OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS mandatory
        DESCRIPTION
        "The number of bytes that were counted as red."
        ::= { genEquipPmEthernetIngressPolicerEtherType3StatisticsEntry 8 }



--
-- Interface physical Port RMON statistics - sw-ap-l2-if-phy-rmon-statistics-table
--

genEquipPmEthernetRmonStatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthernetRmonStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface physical Port RMON statistics."
        ::= { genEquipPmAll 11 }

genEquipPmEthernetRmonStatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthernetRmonStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Interface physical Port RMON statistics."
        INDEX { genEquipPmEthernetRmonStatisticsIfIndex }
        ::= { genEquipPmEthernetRmonStatisticsTable 1 }

GenEquipPmEthernetRmonStatisticsEntry ::=
	SEQUENCE {
		genEquipPmEthernetRmonStatisticsIfIndex
			INTEGER,
		genEquipPmEthernetRmonStatisticsClearOnRead
			NoYes,
		genEquipPmEthernetRmonStatisticsTxByteCount
			Counter64,
		genEquipPmEthernetRmonStatisticsTxFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxMulticastFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxBroadcastFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxControlFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxPauseFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxFcsErrorFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxLengthErrorFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxOversizeFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxUndersizeFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxFragmentFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTxJabberFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTx64FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTx65-127FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTx128-255FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTx256-511FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTx512-1023FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTx1024-1518FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsTx1519-1522FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxByteCount
			Counter64,
		genEquipPmEthernetRmonStatisticsRxFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxMulticastFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxBroadcastFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxControlFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxPauseFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxFcsErrorFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxLengthErrorFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxcode-ErrorCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxoversizeFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxundersize-ErrorFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxFragmentFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRx64FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRx65-127FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRx128-255FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRx256-511FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRx512-1023FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRx1024-1518FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRx1519-1522FrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxExceedmaxFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxExceedMaxWithErrorFrameCount
			Counter,
		genEquipPmEthernetRmonStatisticsRxJabberFrameCount
			Counter
	}

genEquipPmEthernetRmonStatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Ethernet Physical port if-index table key"
        ::= { genEquipPmEthernetRmonStatisticsEntry 1 }

genEquipPmEthernetRmonStatisticsClearOnRead OBJECT-TYPE
        SYNTAX  NoYes
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "Clear on read"
        ::= { genEquipPmEthernetRmonStatisticsEntry 2 }

genEquipPmEthernetRmonStatisticsTxByteCount OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX byte count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 3 }

genEquipPmEthernetRmonStatisticsTxFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 4 }

genEquipPmEthernetRmonStatisticsTxMulticastFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX multicast frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 5 }

genEquipPmEthernetRmonStatisticsTxBroadcastFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX broadcast frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 6 }

genEquipPmEthernetRmonStatisticsTxControlFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX control frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 7 }

genEquipPmEthernetRmonStatisticsTxPauseFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX pause frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 8 }

genEquipPmEthernetRmonStatisticsTxFcsErrorFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX fcs error frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 9 }

genEquipPmEthernetRmonStatisticsTxLengthErrorFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX length error frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 10 }

genEquipPmEthernetRmonStatisticsTxOversizeFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX oversize frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 11 }

genEquipPmEthernetRmonStatisticsTxUndersizeFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX undersize frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 12 }

genEquipPmEthernetRmonStatisticsTxFragmentFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX fragment frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 13 }

genEquipPmEthernetRmonStatisticsTxJabberFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX jabber frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 14 }

genEquipPmEthernetRmonStatisticsTx64FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX 64 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 15 }

genEquipPmEthernetRmonStatisticsTx65-127FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX 65-127 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 16 }

genEquipPmEthernetRmonStatisticsTx128-255FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX 128-255 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 17 }

genEquipPmEthernetRmonStatisticsTx256-511FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX 256-511 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 18 }

genEquipPmEthernetRmonStatisticsTx512-1023FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX 512-1023 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 19 }

genEquipPmEthernetRmonStatisticsTx1024-1518FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX 1024-1518 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 20 }

genEquipPmEthernetRmonStatisticsTx1519-1522FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "TX 1519-1522 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 21 }

genEquipPmEthernetRmonStatisticsRxByteCount OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX byte count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 22 }

genEquipPmEthernetRmonStatisticsRxFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 23 }

genEquipPmEthernetRmonStatisticsRxMulticastFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX multicast frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 24 }

genEquipPmEthernetRmonStatisticsRxBroadcastFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX broadcast frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 25 }

genEquipPmEthernetRmonStatisticsRxControlFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX control frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 26 }

genEquipPmEthernetRmonStatisticsRxPauseFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX pause frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 27 }

genEquipPmEthernetRmonStatisticsRxFcsErrorFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX fcs error frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 28 }

genEquipPmEthernetRmonStatisticsRxLengthErrorFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX length error frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 29 }

genEquipPmEthernetRmonStatisticsRxcode-ErrorCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX code error count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 30 }

genEquipPmEthernetRmonStatisticsRxoversizeFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX oversize frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 31 }

genEquipPmEthernetRmonStatisticsRxundersize-ErrorFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX undersize error frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 32 }

genEquipPmEthernetRmonStatisticsRxFragmentFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX fragment frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 33 }

genEquipPmEthernetRmonStatisticsRx64FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX 64 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 35 }

genEquipPmEthernetRmonStatisticsRx65-127FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX 65-127 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 36 }

genEquipPmEthernetRmonStatisticsRx128-255FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX 128-255 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 37 }

genEquipPmEthernetRmonStatisticsRx256-511FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX 256-511 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 38 }

genEquipPmEthernetRmonStatisticsRx512-1023FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX 512-1023 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 39 }

genEquipPmEthernetRmonStatisticsRx1024-1518FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX 1024-1518 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 40 }

genEquipPmEthernetRmonStatisticsRx1519-1522FrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX 1519-1522 frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 41 }

genEquipPmEthernetRmonStatisticsRxExceedmaxFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX exceed max frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 42 }

genEquipPmEthernetRmonStatisticsRxExceedMaxWithErrorFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX exceed max with error frame count"
        ::= { genEquipPmEthernetRmonStatisticsEntry 43 }

genEquipPmEthernetRmonStatisticsRxJabberFrameCount OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "RX jabber frame count - frames with length &gt; 1518 bytes (1522 bytes for VLAN tagged frames) with errors"
        ::= { genEquipPmEthernetRmonStatisticsEntry 44 }

--
-- Service queues aggragation statistics - sw-ap-l3-srv-egress-queues-aggragate-statistics-table
--

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Service queues aggragation statistics."
        ::= { genEquipPmAll 12 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Service queues aggragation statistics."
        INDEX { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsIfIndex,
				genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsServiceIndex}
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTable 1 }

GenEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry ::=
	SEQUENCE {
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsIfIndex
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsServiceIndex
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsClearOnRead
			NoYes,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenPacket
			Counter64,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenBytes
			Counter64,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenBitsPerSecond
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedGreenPacket
			Counter64,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedGreenBytes
			Counter64,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowPacket
			Counter64,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowBytes
			Counter64,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowBitsPerSecond
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedYellowPacket
			Counter64,
		genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedYellowBytes
			Counter64
	}

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "ifIndex"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 1 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsServiceIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Egress service bundle ID"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 2 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsClearOnRead OBJECT-TYPE
        SYNTAX  NoYes
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "clear on read"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 3 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenPacket OBJECT-TYPE
        SYNTAX  Counter64
		ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted green packet"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 4 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted green bytes"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 5 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedGreenBitsPerSecond OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted green bits per second"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 6 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedGreenPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "dropped green packet"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 7 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedGreenBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "dropped green bytes"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 8 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted yellow packet"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 9 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted yellow bytes"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 10 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsTransmittedYellowBitsPerSecond OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted yellow bits per second"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 11 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedYellowPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Tdropped yellow packet"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 12 }

genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsDroppedYellowBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "dropped yellow bytes"
        ::= { genEquipServicesCETTmPmSpEgressQueuesAggragateStatisticsEntry 13 }

--
-- Cos Service Point ingress Policer statistics - sw-ap-l4-srv-sp-cos-ingress-policer-statistics-table
--

genEquipServicesCetSpPmCosIngressPolicerStatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipServicesCetSpPmCosIngressPolicerStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Cos Service Point ingress Policer statistics."
        ::= { genEquipPmAll 13 }

genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipServicesCetSpPmCosIngressPolicerStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Cos Service Point ingress Policer statistics."
        INDEX { genEquipServicesCetSpPmCosIngressPolicerStatiServiceIndex,
				genEquipServicesCetSpPmCosIngressPolicerStatiSpIndex,
				genEquipServicesCetSpPmCosIngressPolicerStatiCos }
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsTable 1 }

GenEquipServicesCetSpPmCosIngressPolicerStatisticsEntry ::=
	SEQUENCE {
		genEquipServicesCetSpPmCosIngressPolicerStatiServiceIndex
			INTEGER,
		genEquipServicesCetSpPmCosIngressPolicerStatiSpIndex
			INTEGER,
		genEquipServicesCetSpPmCosIngressPolicerStatiCos
			INTEGER,
		genEquipServicesCetSpPmCosIngressPolicerStatiClearOnRead
			NoYes,
		genEquipServicesCetSpPmCosIngressPolicerStatiGreenPacket
			Counter64,
		genEquipServicesCetSpPmCosIngressPolicerStatiGreenBytes
			Counter64,
		genEquipServicesCetSpPmCosIngressPolicerStatiYellowPacket
			Counter64,
		genEquipServicesCetSpPmCosIngressPolicerStatiYellowBytes
			Counter64,
		genEquipServicesCetSpPmCosIngressPolicerStatiRedPacket
			Counter64,
		genEquipServicesCetSpPmCosIngressPolicerStatiRedBytes
			Counter64
	}

genEquipServicesCetSpPmCosIngressPolicerStatiServiceIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "service-index"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 1 }

genEquipServicesCetSpPmCosIngressPolicerStatiSpIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "sp-index"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 2 }

genEquipServicesCetSpPmCosIngressPolicerStatiCos OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "cos index"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 3 }

genEquipServicesCetSpPmCosIngressPolicerStatiClearOnRead OBJECT-TYPE
        SYNTAX  NoYes
		ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "Clear on read"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 4 }

genEquipServicesCetSpPmCosIngressPolicerStatiGreenPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "green-packet"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 5 }

genEquipServicesCetSpPmCosIngressPolicerStatiGreenBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "green-bytes"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 6 }

genEquipServicesCetSpPmCosIngressPolicerStatiYellowPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "yellow-packet"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 7 }

genEquipServicesCetSpPmCosIngressPolicerStatiYellowBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "yellow-bytes"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 8 }

genEquipServicesCetSpPmCosIngressPolicerStatiRedPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "red-packet"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 9 }

genEquipServicesCetSpPmCosIngressPolicerStatiRedBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "red-bytes"
        ::= { genEquipServicesCetSpPmCosIngressPolicerStatisticsEntry 10 }

--
-- Service Point ingress Policer statistics - sw-ap-l4-srv-sp-ingress-policer-statistics-table
--

genEquipServicesCetSpPmIngressPolicerStatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipServicesCetSpPmIngressPolicerStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Service Point ingress Policer statistics."
        ::= { genEquipPmAll 14 }

genEquipServicesCetSpPmIngressPolicerStatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipServicesCetSpPmIngressPolicerStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Service Point ingress Policer statistics."
        INDEX { genEquipServicesCetSpPmIngressPolicerStatiServiceIndex,
				genEquipServicesCetSpPmIngressPolicerStatiSpIndex }
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsTable 1 }

GenEquipServicesCetSpPmIngressPolicerStatisticsEntry ::=
	SEQUENCE {
		genEquipServicesCetSpPmIngressPolicerStatiServiceIndex
			INTEGER,
		genEquipServicesCetSpPmIngressPolicerStatiSpIndex
			INTEGER,
		genEquipServicesCetSpPmIngressPolicerStatiClearOnRead
			NoYes,
		genEquipServicesCetSpPmIngressPolicerStatiGreenPacket
			Counter64,
		genEquipServicesCetSpPmIngressPolicerStatiGreenBytes
			Counter64,
		genEquipServicesCetSpPmIngressPolicerStatiYellowPacket
			Counter64,
		genEquipServicesCetSpPmIngressPolicerStatiYellowBytes
			Counter64,
		genEquipServicesCetSpPmIngressPolicerStatiRedPacket
			Counter64,
		genEquipServicesCetSpPmIngressPolicerStatiRedBytes
			Counter64
	}

genEquipServicesCetSpPmIngressPolicerStatiServiceIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "service-index"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 1 }

genEquipServicesCetSpPmIngressPolicerStatiSpIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "sp-index"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 2 }

genEquipServicesCetSpPmIngressPolicerStatiClearOnRead OBJECT-TYPE
        SYNTAX  NoYes
		ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "Clear on read"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 3 }

genEquipServicesCetSpPmIngressPolicerStatiGreenPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "green-packet"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 4 }

genEquipServicesCetSpPmIngressPolicerStatiGreenBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "green-bytes"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 5 }

genEquipServicesCetSpPmIngressPolicerStatiYellowPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "yellow-packet"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 6 }

genEquipServicesCetSpPmIngressPolicerStatiYellowBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "yellow-bytes"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 7 }

genEquipServicesCetSpPmIngressPolicerStatiRedPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "red-packet"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 8 }

genEquipServicesCetSpPmIngressPolicerStatiRedBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "red-bytes"
        ::= { genEquipServicesCetSpPmIngressPolicerStatisticsEntry 9 }

--
-- Service Point egress queue statistics - sw-ap-l4-srv-sp-egress-queue-statistics-table
--

genEquipServicesCETTmPmSpEgressQueueStatisticsTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipServicesCETTmPmSpEgressQueueStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Service Point egress queue statistics."
        ::= { genEquipPmAll 15 }

genEquipServicesCETTmPmSpEgressQueueStatisticsEntry OBJECT-TYPE
        SYNTAX GenEquipServicesCETTmPmSpEgressQueueStatisticsEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "Service Point egress queue statistics."
        INDEX { genEquipServicesCETTmPmSpEgressQueueStatisticsIfIndex,
				genEquipServicesCETTmPmSpEgressQueueStatisticsServiceIndex,
				genEquipServicesCETTmPmSpEgressQueueStatisticsCosQueueIndex	}
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsTable 1 }

GenEquipServicesCETTmPmSpEgressQueueStatisticsEntry ::=
	SEQUENCE {
		genEquipServicesCETTmPmSpEgressQueueStatisticsIfIndex
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueueStatisticsServiceIndex
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueueStatisticsCosQueueIndex
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueueStatisticsClearOnRead
			NoYes,
		genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenPacket
			Counter64,
		genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenBytes
			Counter64,
		genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenBitsPerSecond
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedGreenPacket
			Counter64,
		genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedGreenBytes
			Counter64,
		genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowPacket
			Counter64,
		genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowBytes
			Counter64,
		genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowBitsPerSecond
			INTEGER,
		genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedYellowPacket
			Counter64,
		genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedYellowBytes
			Counter64
	}

genEquipServicesCETTmPmSpEgressQueueStatisticsIfIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "ifindex"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 1 }

genEquipServicesCETTmPmSpEgressQueueStatisticsServiceIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Servic class ID"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 2 }

genEquipServicesCETTmPmSpEgressQueueStatisticsCosQueueIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "cos-queue-index"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 3 }

genEquipServicesCETTmPmSpEgressQueueStatisticsClearOnRead OBJECT-TYPE
        SYNTAX  NoYes
		ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
        "Clear on read"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 4 }

genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted-green-packet"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 5 }

genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted-green-bytes"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 6 }

genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedGreenBitsPerSecond OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted-green-bits-per-second"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 7 }

genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedGreenPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "dropped-green-packet"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 8 }

genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedGreenBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "dropped-green-bytes"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 9 }

genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted-yellow-packet"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 10 }

genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted-yellow-bytes"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 11 }

genEquipServicesCETTmPmSpEgressQueueStatisticsTransmittedYellowBitsPerSecond OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "transmitted-yellow-bits-per-second"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 12 }

genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedYellowPacket OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "dropped-yellow-packet"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 13 }

genEquipServicesCETTmPmSpEgressQueueStatisticsDroppedYellowBytes OBJECT-TYPE
        SYNTAX  Counter64
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "dropped-yellow-bytes"
        ::= { genEquipServicesCETTmPmSpEgressQueueStatisticsEntry 14 }


-- PM Utilization
genEquipPmUtilization	OBJECT IDENTIFIER ::= {genEquipPmAll 16}

-- PM CPU Utilization
genEquipPmUtilizationCPU	OBJECT IDENTIFIER ::= {genEquipPmUtilization 1}

genEquipPmUtilizationCPUAdmin  OBJECT-TYPE
		SYNTAX  EnableDisable
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"CPU utilization PM admin"
        ::= { genEquipPmUtilizationCPU 1 }

genEquipPmUtilizationCPUThreshold  OBJECT-TYPE
		SYNTAX  INTEGER (0..100)
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"User defined threshold for CPU utilization PM."
        ::= { genEquipPmUtilizationCPU 2 }

genEquipPmUtilizationCPUTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmUtilizationCPUEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The CPU Utilization PMs"
        ::= { genEquipPmUtilizationCPU 3 }

genEquipPmUtilizationCPUEntry OBJECT-TYPE
        SYNTAX GenEquipPmUtilizationCPUEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The CPU Utilization PMs"
        INDEX { genEquipPmUtilizationCPUPmType, genEquipPmUtilizationCPUInterval }
        ::= { genEquipPmUtilizationCPUTable 1 }

GenEquipPmUtilizationCPUEntry ::=
            SEQUENCE {
		genEquipPmUtilizationCPUPmType				PmTableType,
		genEquipPmUtilizationCPUInterval			INTEGER,
		genEquipPmUtilizationCPUPeakUtilization		INTEGER,
		genEquipPmUtilizationCPUAverageUtilization	INTEGER,
		genEquipPmUtilizationCPUMinimumUtilization	INTEGER,
		genEquipPmUtilizationCPUExceedUtilization	INTEGER,
        genEquipPmUtilizationCPUIDF					Integrity
	}

genEquipPmUtilizationCPUPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmUtilizationCPUEntry 1 }

genEquipPmUtilizationCPUInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM"
        ::= { genEquipPmUtilizationCPUEntry 2 }

genEquipPmUtilizationCPUPeakUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Peak CPU utilization of the current interval."
		::= { genEquipPmUtilizationCPUEntry 3 }

genEquipPmUtilizationCPUAverageUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Average CPU utilization of the current interval."
		::= { genEquipPmUtilizationCPUEntry 4 }

genEquipPmUtilizationCPUMinimumUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Minimal CPU utilization of the current interval."
		::= { genEquipPmUtilizationCPUEntry 5 }

genEquipPmUtilizationCPUExceedUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of seconds in the current interval when CPU utilization exceeded user defined threshold."
		::= { genEquipPmUtilizationCPUEntry 6 }

genEquipPmUtilizationCPUIDF  OBJECT-TYPE
		SYNTAX  Integrity
		ACCESS  read-only
		STATUS mandatory
		DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
		::= { genEquipPmUtilizationCPUEntry 7 }



-- PM Memory Utilization
genEquipPmUtilizationMem	OBJECT IDENTIFIER ::= {genEquipPmUtilization 2}

genEquipPmUtilizationMemAdmin  OBJECT-TYPE
		SYNTAX  EnableDisable
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"Memory utilization PM admin"
        ::= { genEquipPmUtilizationMem 1 }

genEquipPmUtilizationMemThreshold  OBJECT-TYPE
		SYNTAX  INTEGER (0..100)
        ACCESS  read-write
        STATUS mandatory
        DESCRIPTION
		"Memory threshold for Ethernet port utilization PM."
        ::= { genEquipPmUtilizationMem 2 }

genEquipPmUtilizationMemTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmUtilizationMemEntry
        ACCESS  not-accessible
        STATUS mandatory
       DESCRIPTION
        "The Memory Utilization PMs"
        ::= { genEquipPmUtilizationMem 3 }

genEquipPmUtilizationMemEntry OBJECT-TYPE
        SYNTAX GenEquipPmUtilizationMemEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "The Memory Utilization PMs"
        INDEX { genEquipPmUtilizationMemPmType, genEquipPmUtilizationMemInterval }
        ::= { genEquipPmUtilizationMemTable 1 }

GenEquipPmUtilizationMemEntry ::=
            SEQUENCE {
		genEquipPmUtilizationMemPmType				PmTableType,
		genEquipPmUtilizationMemInterval			INTEGER,
		genEquipPmUtilizationMemPeakUtilization		INTEGER,
		genEquipPmUtilizationMemAverageUtilization	INTEGER,
		genEquipPmUtilizationMemMinimumUtilization	INTEGER,
		genEquipPmUtilizationMemExceedUtilization	INTEGER,
        genEquipPmUtilizationMemIDF					Integrity
	}

genEquipPmUtilizationMemPmType OBJECT-TYPE
        SYNTAX  PmTableType
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access, 15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmUtilizationMemEntry 1 }

genEquipPmUtilizationMemInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The interval of the PM"
        ::= { genEquipPmUtilizationMemEntry 2 }

genEquipPmUtilizationMemPeakUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Peak Memory utilization of the current interval."
		::= { genEquipPmUtilizationMemEntry 3 }

genEquipPmUtilizationMemAverageUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Average Memory utilization of the current interval."
		::= { genEquipPmUtilizationMemEntry 4 }

genEquipPmUtilizationMemMinimumUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of seconds in current interval when Memory utilization exceeded the user defined threshold."
		::= { genEquipPmUtilizationMemEntry 5 }

genEquipPmUtilizationMemExceedUtilization	OBJECT-TYPE
        SYNTAX		INTEGER
        ACCESS  	read-only
        STATUS 		mandatory
        DESCRIPTION
		"Number of seconds in current interval when Memory utilization exceeded the user defined threshold."
		::= { genEquipPmUtilizationMemEntry 6 }

genEquipPmUtilizationMemIDF  OBJECT-TYPE
		SYNTAX  Integrity
		ACCESS  read-only
		STATUS mandatory
		DESCRIPTION
		"This value indicates if the IDF (Invalid Data Flag), was set."
		::= { genEquipPmUtilizationMemEntry 7 }

-- PM Ethernet Port
genEquipPmEthernet	OBJECT IDENTIFIER ::= {genEquipPmAll 17}


--
-- PM on Ethernet port counters - sw-ap-l2-if-phy-pm-table
--

genEquipPmEthernetPortTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF GenEquipPmEthernetPortEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "PM on Ethernet port counters."
        ::= { genEquipPmEthernet 1 }

genEquipPmEthernetPortEntry OBJECT-TYPE
        SYNTAX GenEquipPmEthernetPortEntry
        ACCESS  not-accessible
        STATUS mandatory
        DESCRIPTION
        "PM on Ethernet port counters entry."
        INDEX { genEquipPmEthernetPortPmType,
				ifIndex,
				genEquipPmEthernetPortPmInterval}
        ::= { genEquipPmEthernetPortTable 1 }

GenEquipPmEthernetPortEntry ::=
	SEQUENCE {
		genEquipPmEthernetPortPmType
			INTEGER,
		genEquipPmEthernetPortPmInterval
			INTEGER,
	    genEquipPmEthernetPortRxAvgBcastPackets
			INTEGER,
	    genEquipPmEthernetPortRxPeakBcastPackets
			INTEGER,
	    genEquipPmEthernetPortRxBytesLayer1ExcedThSecCnt
			INTEGER,
	    genEquipPmEthernetPortRxAvgBytesLayer1
			INTEGER,
	    genEquipPmEthernetPortRxPeakBytesLayer1
			INTEGER,
	    genEquipPmEthernetPortRxAvgBytesLayer2
			INTEGER,
		genEquipPmEthernetPortRxPeakBytesLayer2
			INTEGER,
		genEquipPmEthernetPortRxAvgMcastPackets
			INTEGER,
		genEquipPmEthernetPortRxPeakMcastPackets
			INTEGER,
		genEquipPmEthernetPortRxAvgPackets
			INTEGER,
		genEquipPmEthernetPortRxPeakPackets
			INTEGER,
		genEquipPmEthernetPortTxAvgBcastPackets
			INTEGER,
		genEquipPmEthernetPortTxPeakBcastPackets
			INTEGER,
		genEquipPmEthernetPortTxBytesLayer1ExcedThSecCnt
			INTEGER,
		genEquipPmEthernetPortTxAvgBytesLayer1
			INTEGER,
		genEquipPmEthernetPortTxPeakBytesLayer1
			INTEGER,
		genEquipPmEthernetPortTxAvgBytesLayer2
			INTEGER,
		genEquipPmEthernetPortTxPeakBytesLayer2
			INTEGER,
		genEquipPmEthernetPortTxAvgMcastPackets
			INTEGER,
		genEquipPmEthernetPortTxPeakMcastPackets
			INTEGER,
		genEquipPmEthernetPortTxAvgPackets
			INTEGER,
		genEquipPmEthernetPortTxPeakPackets
			INTEGER,
		genEquipPmEthernetPortPmIDF
			INTEGER
	}

genEquipPmEthernetPortPmType OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "This value indicates the PM Type table to access,
		15 min, current 15 min, 24 hours or current 24 hours"
        ::= { genEquipPmEthernetPortEntry 1 }

genEquipPmEthernetPortPmInterval OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "The number of the interval: 1-30 in case the interval is 24 hours
		or 1-96 in case the interval is 15 minutes"
        ::= { genEquipPmEthernetPortEntry 2 }

genEquipPmEthernetPortRxAvgBcastPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average received broadcast packets"
        ::= { genEquipPmEthernetPortEntry 3 }

genEquipPmEthernetPortRxPeakBcastPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak received broadcast packets"
        ::= { genEquipPmEthernetPortEntry 4 }

genEquipPmEthernetPortRxBytesLayer1ExcedThSecCnt OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Counter of seconds in interval when received bytes in Layer1 exceeded threshold"
        ::= { genEquipPmEthernetPortEntry 5 }

genEquipPmEthernetPortRxAvgBytesLayer1 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average received bytes in Layer1"
        ::= { genEquipPmEthernetPortEntry 6 }

genEquipPmEthernetPortRxPeakBytesLayer1 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak received bytes in Layer1"
        ::= { genEquipPmEthernetPortEntry 7 }

genEquipPmEthernetPortRxAvgBytesLayer2 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average received bytes in Layer2"
        ::= { genEquipPmEthernetPortEntry 8 }

genEquipPmEthernetPortRxPeakBytesLayer2 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak received bytes in Layer2"
        ::= { genEquipPmEthernetPortEntry 9 }

genEquipPmEthernetPortRxAvgMcastPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average received multicast packets"
        ::= { genEquipPmEthernetPortEntry 10 }

genEquipPmEthernetPortRxPeakMcastPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak received multicast packets"
        ::= { genEquipPmEthernetPortEntry 11 }

genEquipPmEthernetPortRxAvgPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average received packets"
        ::= { genEquipPmEthernetPortEntry 12 }

genEquipPmEthernetPortRxPeakPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak received packets"
        ::= { genEquipPmEthernetPortEntry 13 }

genEquipPmEthernetPortTxAvgBcastPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average transmitted broadcast packets"
        ::= { genEquipPmEthernetPortEntry 14 }

genEquipPmEthernetPortTxPeakBcastPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak transmitted broadcast packets"
        ::= { genEquipPmEthernetPortEntry 15 }

genEquipPmEthernetPortTxBytesLayer1ExcedThSecCnt OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Counter of seconds in interval when transmitted bytes in Layer1 exceeded threshold"
        ::= { genEquipPmEthernetPortEntry 16 }

genEquipPmEthernetPortTxAvgBytesLayer1 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average transmitted bytes in Layer1"
        ::= { genEquipPmEthernetPortEntry 17 }

genEquipPmEthernetPortTxPeakBytesLayer1 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak transmitted bytes in Layer1"
        ::= { genEquipPmEthernetPortEntry 18 }

genEquipPmEthernetPortTxAvgBytesLayer2 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average transmitted bytes in Layer2"
        ::= { genEquipPmEthernetPortEntry 19 }

genEquipPmEthernetPortTxPeakBytesLayer2 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak transmitted bytes in Layer2"
        ::= { genEquipPmEthernetPortEntry 20 }

genEquipPmEthernetPortTxAvgMcastPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average transmitted multicast packets"
        ::= { genEquipPmEthernetPortEntry 21 }

genEquipPmEthernetPortTxPeakMcastPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak transmitted multicast packets"
        ::= { genEquipPmEthernetPortEntry 22 }

genEquipPmEthernetPortTxAvgPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Average transmitted packets"
        ::= { genEquipPmEthernetPortEntry 23 }

genEquipPmEthernetPortTxPeakPackets OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Peak transmitted packets"
        ::= { genEquipPmEthernetPortEntry 24 }

genEquipPmEthernetPortPmIDF OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS 	mandatory
        DESCRIPTION
        "Indicates if the performance values of the interval can be trusted"
        ::= { genEquipPmEthernetPortEntry 25 }

-- PM Scalars
genEquipPMStatistics	OBJECT IDENTIFIER ::= {genEquipPM 4}

genEquipRMONResetCounters  OBJECT-TYPE
		SYNTAX  OffOn
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
		"Clear all Ethernet RMON counters."
        ::= { genEquipPMStatistics 1 }

genEquipPMStatisticsResetAllL2PortPm OBJECT-TYPE
		SYNTAX  OffOn
        ACCESS  read-write
        STATUS 	mandatory
        DESCRIPTION
		"Clear all L2 port PMs."
        ::= { genEquipPMStatistics 2 }


END