	-- SmartOptics Enterprise Specific Alarm MIB.
--
-- Copyright (c) 2011, SmartOptics
-- All rights reserved
--

MSERIES-ALARM-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Counter32, Integer32
    FROM SNMPv2-SMI
    DisplayString, DateAndTime
    FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
    FROM SNMPv2-CONF
    AlarmPerceivedSeverity, AlarmNotificationType, AlarmProbableCause, UnitType, PortType
    FROM MSERIES-TC
    mseries
    FROM MSERIES-MIB;

smartAlarm      MODULE-IDENTITY
                LAST-UPDATED    "201402121415Z"
                ORGANIZATION    "SmartOptics"
                CONTACT-INFO    "http://www.smartoptics.com"
                DESCRIPTION
                                "This is the enterprise specific Alarm MIB for SmartOptics M-Series"
                REVISION        "201402121415Z"
                DESCRIPTION
                                "Added alarmLogList and smartAlarmMIBConformance."

                REVISION        "201310151341Z"
                DESCRIPTION
                                "Added alarmHostName, alarmPortName and alarmPortType to AlarmEntry.
                                 Added alarmHostName, alarmPortName and alarmPortType to
                                 alarmNotificationCleared, alarmNotificationWarning,
                                 alarmNotificationMinor, alarmNotificationMajor,
                                 and alarmNotificationCritical.

                                 Also alarmPort reports different numbers against before
                                 (changed from SmartOS v2.1). 1-10 means Line ports
                                 and 11 and above means Client port.

                                 Descriptions are also updated."
                REVISION        "201112050000Z"
                DESCRIPTION
                                "Initial revision.

                                 Added notifications."
                ::=  { mseries 1 }

        alarmGeneral   OBJECT IDENTIFIER
                ::=  { smartAlarm  1}

        alarmActiveList   OBJECT IDENTIFIER
                ::=  { smartAlarm  2}

        alarmLogList   OBJECT IDENTIFIER
                ::=  { smartAlarm  3}

        alarmNotifications   OBJECT IDENTIFIER
                ::=  { smartAlarm  4}

        smartAlarmMIBConformance   OBJECT IDENTIFIER
                ::=  { smartAlarm  5}

        smartAlarmGroups   OBJECT IDENTIFIER
                ::=  { smartAlarmMIBConformance  1}

        smartAlarmCompliances   OBJECT IDENTIFIER
                ::=  { smartAlarmMIBConformance  2}

--
-- General alarm group
--

smartAlarmGeneralLastSeqNumber OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The sequence number of the last sent notification."
    ::= { alarmGeneral 1 }

smartAlarmGeneralHighestSeverity OBJECT-TYPE
    SYNTAX      AlarmPerceivedSeverity
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The current highest severity of the active alarms."
    ::= { alarmGeneral 2 }

smartAlarmGeneralNumberActiveList OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of active alarms in the alarmActiveList."
    ::= { alarmGeneral 3 }

smartAlarmGeneralNumberLogList OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of alarms in the alarmLogList."
    ::= { alarmGeneral 4 }

--
-- Alarm active list group
--

alarmActiveTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF AlarmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The active alarm list."
    ::= { alarmActiveList 1 }

alarmEntry OBJECT-TYPE
    SYNTAX      AlarmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the active alarm list."
    INDEX { alarmIndex }
    ::= { alarmActiveTable 1 }

AlarmEntry ::=
    SEQUENCE {
        alarmIndex                      Unsigned32,
        alarmUnit                       UnitType,
        alarmPort                       Integer32,
        alarmText                       DisplayString,
        alarmSeverity                   AlarmPerceivedSeverity,
        alarmActivationTime             DateAndTime,
        alarmCeaseTime                  DateAndTime,
        alarmSeqNumber                  Counter32,
        alarmHostName                   DisplayString,
        alarmPortName                   DisplayString,
        alarmPortType                   PortType,
        alarmType                       AlarmNotificationType,
        alarmCause                      AlarmProbableCause,
        alarmPortAlias                  DisplayString
}

alarmIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An unique index assigned to each alarm."
    ::= { alarmEntry 1 }

alarmUnit OBJECT-TYPE
    SYNTAX      UnitType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarming unit associated with this alarm.
        undefined(0), nmb(1), psu1(2), psu2(3), fan(4), system&#40;5&#41;,
        slaveNmb(6), slavePsu1(7), slavePsu2(8), slaveFan(9)."
    ::= { alarmEntry 2 }

alarmPort OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarming port associated with this alarm.
        1-10 is Line Ports. 11 and higher is Client ports. For non port alarms this value is 0."
    ::= { alarmEntry 3 }

alarmText OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The additional text for the alarm."
    ::= { alarmEntry 4 }

alarmSeverity OBJECT-TYPE
    SYNTAX      AlarmPerceivedSeverity
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The severity of the alarm as defined in
        ITU-T X.733."
    ::= { alarmEntry 5 }

alarmActivationTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the alarm was created."
    ::= { alarmEntry 6 }

alarmCeaseTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the alarm was ceased."
    ::= { alarmEntry 7 }

alarmSeqNumber OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The last sequence number used when issuing
        a notification for this alarm."
    ::= { alarmEntry 8 }

alarmHostName OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The hostname."
    ::= { alarmEntry 9 }

alarmPortName OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Port Name."
    ::= { alarmEntry 10 }

alarmPortType OBJECT-TYPE
    SYNTAX      PortType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Port Type. undefined(0), rx(1), tx(2), biDi(3)."
    ::= { alarmEntry 11 }

alarmType OBJECT-TYPE
    SYNTAX      AlarmNotificationType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The type of alarm as defined in ITU-T X.733
         undefined (0),
         other (1),
         communicationsAlarm (2),
         qualityOfServiceAlarm (3),
         processingErrorAlarm (4),
         equipmentAlarm (5),
         environmental (6),
         integrityViolation (7),
         operationalViolation (8),
         physicalViolation(9),
         securityServiceOrMechanismViloation (10),
         timeDomainViolation (11)"
    ::= { alarmEntry 12 }

alarmCause OBJECT-TYPE
    SYNTAX      AlarmProbableCause
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm probable cause as defined in ITU-T X.733.
        undefined (0)
        adapterError (1)                       -- Equipment
        applicationSubsystemFailure (2)        -- Processing
        bandwidthReduced (3)                   -- Quality of service
        callEstablishmentError (4)             -- Communications
        communicationsProtocolError (5)        -- Communications
        communicationsSubsystemFailure (6)     -- Communications
        configurationOrCustomizationError (7)  -- Processing
        congestion (8)                         -- Quality of service
        corruptData (9)                        -- Processing
        cpuCyclesLimitExceeded (10)            -- Processing
        dTEdCEInterfaceError (11)              -- Communications
        datasetOrModemError (12)               -- Equipment
        degradedSignal (13)                    -- Communications
        enclosureDoorOpen (14)                 -- Environmental
        equipmentMalfunction (15)              -- Equipment
        excessiveVibration (16)                -- Environmental
        fileError (17)                         -- Processing
        fireDetected (18)                      -- Environmental
        floodDetected (19)                     -- Environmental
        framingError (20)                      -- Communications
        heatingOrVentilationOrCoolingSystemProblem (21) -- Environmental
        humidityUnacceptable (22)              -- Environmental
        inputDeviceError (23)                  -- Equipment
        inputOutputDeviceError (24)            -- Equipment
        lANError (25)                          -- Communications
        leakDetected (26)                      -- Environmental
        localNodeTransmissionError (27)        -- Communications
        lossOfFrame (28)                       -- Communications
        lossOfSignal (29)                      -- Communications
        materialSupplyExhausted (30)           -- Environmental
        multiplexerProblem (31)                -- Equipment
        outOfMemory (32)                       -- Processing
        outputDeviceError (33)                 -- Equipment
        performanceDegraded (34)               -- Quality of service
        powerProblem (35)                      -- Equipment
        pressureUnacceptable (36)              -- Environmental
        processorProblem (37)                  -- Equipment
        pumpFailure (38)                       -- Environmental
        queueSizeExceeded (39)                 -- Quality of service
        receiveFailure (40)                    -- Equipment
        receiverFailure (41)                   -- Equipment
        remoteNodeTransmissionError (42)       -- Communications
        resourceAtOrNearingCapacity (43)       -- Quality of service
        responseTimeExcessive (44)             -- Quality of service
        retransmissionRateExcessive (45)       -- Quality of service
        softwareProgramError (46)              -- Processing
        softwareError (47)                     -- Processing
        softwareProgramAbnormallyTerminated (48) -- Processing
        storageCapacityProblem (49)            -- Processing
        temperatureUnacceptable (50)           -- Environmental
        thresholdCrossed (51)                  -- Quality of service
        timingProblem (52)                     -- Equipment
        toxicLeakDetected (53)                 -- Environmental
        transmitFailure (54)                   -- Equipment
        transmitterFailure (55)                -- Equipment
        underlyingResourceUnavailable (56)     -- Processing
        versionMismatch (57)                   -- Processing"
    ::= { alarmEntry 13 }

alarmPortAlias OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Port Alias."
    ::= { alarmEntry 14 }

--
-- Alarm active list group
--

alarmLogTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF AlarmLogEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The active alarm list."
    ::= { alarmLogList 1 }

alarmLogEntry OBJECT-TYPE
    SYNTAX      AlarmLogEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in the alarm log table."
    INDEX { alarmLogIndex }
    ::= { alarmLogTable 1 }

AlarmLogEntry ::=
    SEQUENCE {
        alarmLogIndex                      Unsigned32,
        alarmLogUnit                       UnitType,
        alarmLogPort                       Integer32,
        alarmLogText                       DisplayString,
        alarmLogSeverity                   AlarmPerceivedSeverity,
        alarmLogActivationTime             DateAndTime,
        alarmLogCeaseTime                  DateAndTime,
        alarmLogSeqNumber                  Counter32,
        alarmLogHostName                   DisplayString,
        alarmLogPortName                   DisplayString,
        alarmLogPortType                   PortType,
        alarmLogType                       AlarmNotificationType,
        alarmLogCause                      AlarmProbableCause
}

alarmLogIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An unique index assigned to each alarm."
    ::= { alarmLogEntry 1 }

alarmLogUnit OBJECT-TYPE
    SYNTAX      UnitType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarming unit associated with this alarm.
        undefined(0), nmb(1), psu1(2), psu2(3), fan(4), system&#40;5&#41;,
        slaveNmb(6), slavePsu1(7), slavePsu2(8), slaveFan(9)."
    ::= { alarmLogEntry 2 }

alarmLogPort OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarming port associated with this alarm.
        1-10 is Line Ports. 11 and higher is Client ports. For non port alarms this value is 0."
    ::= { alarmLogEntry 3 }

alarmLogText OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The additional text for the alarm."
    ::= { alarmLogEntry 4 }

alarmLogSeverity OBJECT-TYPE
    SYNTAX      AlarmPerceivedSeverity
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The severity of the alarm as defined in
        ITU-T X.733."
    ::= { alarmLogEntry 5 }

alarmLogActivationTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the alarm was created."
    ::= { alarmLogEntry 6 }

alarmLogCeaseTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The time when the alarm was ceased."
    ::= { alarmLogEntry 7 }

alarmLogSeqNumber OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The last sequence number used when issuing
        a notification for this alarm."
    ::= { alarmLogEntry 8 }

alarmLogHostName OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The hostname."
    ::= { alarmLogEntry 9 }

alarmLogPortName OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Port Name."
    ::= { alarmLogEntry 10 }

alarmLogPortType OBJECT-TYPE
    SYNTAX      PortType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Port Direction. rx(1), tx(2), biDi(3)."
    ::= { alarmLogEntry 11 }

alarmLogType OBJECT-TYPE
    SYNTAX      AlarmNotificationType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The type of alarm as defined in ITU-T X.733
         undefined (0),
         other (1),
         communicationsAlarm (2),
         qualityOfServiceAlarm (3),
         processingErrorAlarm (4),
         equipmentAlarm (5),
         environmental (6),
         integrityViolation (7),
         operationalViolation (8),
         physicalViolation(9),
         securityServiceOrMechanismViloation (10),
         timeDomainViolation (11)"
    ::= { alarmLogEntry 12 }

alarmLogCause OBJECT-TYPE
    SYNTAX      AlarmProbableCause
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm probable cause as defined in ITU-T X.733.
        undefined (0)
        adapterError (1)                       -- Equipment
        applicationSubsystemFailure (2)        -- Processing
        bandwidthReduced (3)                   -- Quality of service
        callEstablishmentError (4)             -- Communications
        communicationsProtocolError (5)        -- Communications
        communicationsSubsystemFailure (6)     -- Communications
        configurationOrCustomizationError (7)  -- Processing
        congestion (8)                         -- Quality of service
        corruptData (9)                        -- Processing
        cpuCyclesLimitExceeded (10)            -- Processing
        dTEdCEInterfaceError (11)              -- Communications
        datasetOrModemError (12)               -- Equipment
        degradedSignal (13)                    -- Communications
        enclosureDoorOpen (14)                 -- Environmental
        equipmentMalfunction (15)              -- Equipment
        excessiveVibration (16)                -- Environmental
        fileError (17)                         -- Processing
        fireDetected (18)                      -- Environmental
        floodDetected (19)                     -- Environmental
        framingError (20)                      -- Communications
        heatingOrVentilationOrCoolingSystemProblem (21) -- Environmental
        humidityUnacceptable (22)              -- Environmental
        inputDeviceError (23)                  -- Equipment
        inputOutputDeviceError (24)            -- Equipment
        lANError (25)                          -- Communications
        leakDetected (26)                      -- Environmental
        localNodeTransmissionError (27)        -- Communications
        lossOfFrame (28)                       -- Communications
        lossOfSignal (29)                      -- Communications
        materialSupplyExhausted (30)           -- Environmental
        multiplexerProblem (31)                -- Equipment
        outOfMemory (32)                       -- Processing
        outputDeviceError (33)                 -- Equipment
        performanceDegraded (34)               -- Quality of service
        powerProblem (35)                      -- Equipment
        pressureUnacceptable (36)              -- Environmental
        processorProblem (37)                  -- Equipment
        pumpFailure (38)                       -- Environmental
        queueSizeExceeded (39)                 -- Quality of service
        receiveFailure (40)                    -- Equipment
        receiverFailure (41)                   -- Equipment
        remoteNodeTransmissionError (42)       -- Communications
        resourceAtOrNearingCapacity (43)       -- Quality of service
        responseTimeExcessive (44)             -- Quality of service
        retransmissionRateExcessive (45)       -- Quality of service
        softwareProgramError (46)              -- Processing
        softwareError (47)                     -- Processing
        softwareProgramAbnormallyTerminated (48) -- Processing
        storageCapacityProblem (49)            -- Processing
        temperatureUnacceptable (50)           -- Environmental
        thresholdCrossed (51)                  -- Quality of service
        timingProblem (52)                     -- Equipment
        toxicLeakDetected (53)                 -- Environmental
        transmitFailure (54)                   -- Equipment
        transmitterFailure (55)                -- Equipment
        underlyingResourceUnavailable (56)     -- Processing
        versionMismatch (57)                   -- Processing"
    ::= { alarmLogEntry 13 }

--
-- Notifications
--

alarmNotifyPrefix OBJECT IDENTIFIER ::= { alarmNotifications 0 }

alarmNotificationCleared NOTIFICATION-TYPE
    OBJECTS {
        alarmIndex,
        alarmUnit,
        alarmPort,
        alarmText,
        alarmSeverity,
        alarmActivationTime,
        alarmCeaseTime,
        alarmSeqNumber,
        alarmHostName,
        alarmPortName,
        alarmPortType,
        alarmPortAlias }
    STATUS      current
    DESCRIPTION
        "Sent when an alarm is cleared."
    ::= { alarmNotifyPrefix 1 }

alarmNotificationWarning NOTIFICATION-TYPE
    OBJECTS {
        alarmIndex,
        alarmUnit,
        alarmPort,
        alarmText,
        alarmSeverity,
        alarmActivationTime,
        alarmCeaseTime,
        alarmSeqNumber,
        alarmHostName,
        alarmPortName,
        alarmPortType,
        alarmPortAlias }
    STATUS      current
    DESCRIPTION
        "Sent when an alarm with warning severity is activated."
    ::= { alarmNotifyPrefix 2 }

alarmNotificationMinor NOTIFICATION-TYPE
    OBJECTS {
        alarmIndex,
        alarmUnit,
        alarmPort,
        alarmText,
        alarmSeverity,
        alarmActivationTime,
        alarmCeaseTime,
        alarmSeqNumber,
        alarmHostName,
        alarmPortName,
        alarmPortType,
        alarmPortAlias }
    STATUS      current
    DESCRIPTION
        "Sent when an alarm with minor severity is activated."
    ::= { alarmNotifyPrefix 3 }

alarmNotificationMajor NOTIFICATION-TYPE
    OBJECTS {
        alarmIndex,
        alarmUnit,
        alarmPort,
        alarmText,
        alarmSeverity,
        alarmActivationTime,
        alarmCeaseTime,
        alarmSeqNumber,
        alarmHostName,
        alarmPortName,
        alarmPortType,
        alarmPortAlias }
    STATUS      current
    DESCRIPTION
        "Sent when an alarm with major severity is activated.."
    ::= { alarmNotifyPrefix 4 }

alarmNotificationCritical NOTIFICATION-TYPE
    OBJECTS {
        alarmIndex,
        alarmUnit,
        alarmPort,
        alarmText,
        alarmSeverity,
        alarmActivationTime,
        alarmCeaseTime,
        alarmSeqNumber,
        alarmHostName,
        alarmPortName,
        alarmPortType,
        alarmPortAlias }
    STATUS      current
    DESCRIPTION
        "Sent when an alarm with critical severity is activated."
    ::= { alarmNotifyPrefix 5 }


-- ----------------------------------------------------
-- Conformance
-- ----------------------------------------------------

-- ----------------------------------------------------
-- Groups
-- ----------------------------------------------------

smartAlarmGeneralGroupV1 OBJECT-GROUP
    OBJECTS   { smartAlarmGeneralLastSeqNumber,
                smartAlarmGeneralHighestSeverity,
                smartAlarmGeneralNumberActiveList,
                smartAlarmGeneralNumberLogList }
    STATUS     current
    DESCRIPTION
           "The general alarm objects V1."
    ::= { smartAlarmGroups 1 }

smartAlarmNotificationGroupV1 NOTIFICATION-GROUP
    NOTIFICATIONS   { alarmNotificationCleared,
                alarmNotificationCritical,
                alarmNotificationMajor,
                alarmNotificationMinor,
                alarmNotificationWarning }
    STATUS     current
    DESCRIPTION
           "The alarm notifications V1."
    ::= { smartAlarmGroups 2 }

smartAlarmActiveTableGroupV1 OBJECT-GROUP
    OBJECTS   { alarmIndex,
                alarmUnit,
                alarmPort,
                alarmText,
                alarmSeverity,
                alarmActivationTime,
                alarmCeaseTime,
                alarmSeqNumber,
                alarmHostName,
                alarmPortName,
                alarmPortType,
                alarmType,
                alarmCause }
    STATUS     current
    DESCRIPTION
           "The active alarm table objects V1."
    ::= { smartAlarmGroups 3 }

smartAlarmLogTableGroupV1 OBJECT-GROUP
    OBJECTS   { alarmLogIndex,
                alarmLogUnit,
                alarmLogPort,
                alarmLogText,
                alarmLogSeverity,
                alarmLogActivationTime,
                alarmLogCeaseTime,
                alarmLogSeqNumber,
                alarmLogHostName,
                alarmLogPortName,
                alarmLogPortType,
                alarmLogType,
                alarmLogCause }
    STATUS     current
    DESCRIPTION
           "The alarm log table objects V1."
    ::= { smartAlarmGroups 4 }

-- ----------------------------------------------------
-- Compliance
-- ----------------------------------------------------

smartAlarmBasicComplV1 MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "Basic implementation requirements for the alarm MIB V1."
    MODULE
        MANDATORY-GROUPS {
            smartAlarmGeneralGroupV1,
            smartAlarmNotificationGroupV1,
            smartAlarmActiveTableGroupV1,
            smartAlarmLogTableGroupV1 }
    ::= { smartAlarmCompliances 1 }

END