UBNT-AFLTU-MIB DEFINITIONS ::= BEGIN

IMPORTS
  MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64, IpAddress
    FROM SNMPv2-SMI
  MODULE-COMPLIANCE, OBJECT-GROUP
    FROM SNMPv2-CONF
  DisplayString, MacAddress
    FROM SNMPv2-TC
  ubntAFLTU, ubntAFLTUGroups 
    FROM UBNT-MIB;

afLTUMIB MODULE-IDENTITY
    LAST-UPDATED "201710300000Z"
    ORGANIZATION "Ubiquiti Networks, Inc."
    CONTACT-INFO "support@ubnt.com"
    DESCRIPTION  "The AFLTU MIB module for Ubiquiti Networks, Inc. entities"
    REVISION "201710300000Z"
    DESCRIPTION "AFLTU.v0.1 revision"
    ::= { ubntAFLTU 1 }

afLTUCompliances  OBJECT IDENTIFIER ::= {ubntAFLTUGroups 1}
afLTUGroups       OBJECT IDENTIFIER ::= {ubntAFLTUGroups 2}

afLTUConfig       OBJECT IDENTIFIER ::= {afLTUMIB 2}
afLTUStatus       OBJECT IDENTIFIER ::= {afLTUMIB 3}
afLTUStationTable OBJECT IDENTIFIER ::= {afLTUMIB 4}
afLTUStats        OBJECT IDENTIFIER ::= {afLTUMIB 5}

--=== MODULE OBJECTS

--=== AFLTU Config

afLTURole OBJECT-TYPE
  SYNTAX	INTEGER {
		        ap  (0),
		        cpe (1)
		      } 
  MAX-ACCESS 	  read-write
  STATUS 	      current
  DESCRIPTION 	"Wireless Role (ap/cpe)"
  ::= { afLTUConfig 1 }
                  
afLTUFrequency OBJECT-TYPE
  SYNTAX     	  Integer32
  UNITS         "MHz"
  MAX-ACCESS 	  read-write
  STATUS 	      current
  DESCRIPTION 	"The main frequency to use in MHz."
  ::= { afLTUConfig 2 }

afLTUAltFreqList OBJECT-TYPE
  SYNTAX     	  DisplayString (SIZE (1..100))
  MAX-ACCESS 	  read-write
  STATUS 	      current
  DESCRIPTION 	"The list of alternative frequencies in MHz. Multiple frequencies should be separated with commas. For example: '5250,5670,5800'."
  ::= { afLTUConfig 3 }
        
afLTUBandwidth OBJECT-TYPE
  SYNTAX     	  INTEGER {bw10M(10),bw20M(20),bw30M(30),bw40M(40),bw50M(50),bw60M(60),bw80M(80),bw100M(100)}
  UNITS         "MHz"
  MAX-ACCESS    read-write
  STATUS        current
  DESCRIPTION   "Wireless channel bandwidth in MHz."
  ::= { afLTUConfig 4 }

afLTUSsid OBJECT-TYPE
  SYNTAX     	DisplayString (SIZE (1..15))
  MAX-ACCESS 	read-write
  STATUS 	current
  DESCRIPTION 	"Radio SSID"
  ::= { afLTUConfig 5 }
        
afLTUTxEIRP OBJECT-TYPE
  SYNTAX        Integer32  (-10..100)
  MAX-ACCESS    read-write
  STATUS        current
  DESCRIPTION   "Tx EIRP in dBm."
  ::= { afLTUConfig 6 }

afLTUAntennaGain OBJECT-TYPE
  SYNTAX        Integer32 (0..40)
  MAX-ACCESS    read-write
  STATUS        current
  DESCRIPTION   "Antenna gain in dBi."
  ::= { afLTUConfig 7 }

afLTUCableLoss OBJECT-TYPE
  SYNTAX        Integer32 (0..10)
  MAX-ACCESS    read-write
  STATUS        current
  DESCRIPTION   "Cable loss in dB."
  ::= { afLTUConfig 8 }
        
afLTUTxRate OBJECT-TYPE
  SYNTAX     	INTEGER
  UNITS       "x"
  MAX-ACCESS 	read-write
  STATUS 	    current
  DESCRIPTION "Tx modulation."
  ::= { afLTUConfig 9 }
        
afLTUTxRateAuto OBJECT-TYPE
  SYNTAX     	INTEGER  {
                disabled  (0),
                enabled   (1)
        	    } 
  MAX-ACCESS 	read-write
  STATUS 	    current
  DESCRIPTION "Automatic Tx moduleation selection. If this is enabled, afLTUTxRate is the maximum modulation for the selection algorithm to select."
  ::= { afLTUConfig 10 }
        
afLTUDistanceScale OBJECT-TYPE
  SYNTAX     	INTEGER (0..5)
  MAX-ACCESS 	read-write
  STATUS 	    current
  DESCRIPTION 	"Distance Scale, options are:
                 0 = 0km
                 1 = <1km
                 2 = <5km
                 3 = <10km
                 4 = <20km
                 5 = <40km"
  ::= { afLTUConfig 11 }
  
--=== AFLTU Status

afLTUMac OBJECT-TYPE
  SYNTAX        MacAddress
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The MAC address of this device"
  ::= { afLTUStatus 1 }

afLTUDevModel OBJECT-TYPE
  SYNTAX	    DisplayString
  MAX-ACCESS 	read-only
  STATUS 	    current
  DESCRIPTION 	"The device model."
  ::= { afLTUStatus 2 }
 
afLTUDevName OBJECT-TYPE
  SYNTAX	    DisplayString
  MAX-ACCESS 	read-only
  STATUS 	    current
  DESCRIPTION 	"The device name."
  ::= { afLTUStatus 3 }
  
afLTUFirmwareVersion OBJECT-TYPE
  SYNTAX	    DisplayString
  MAX-ACCESS 	read-only
  STATUS 	    current
  DESCRIPTION 	"The firmware version running."
  ::= { afLTUStatus 4 }
  
afLTUMemoryUsage OBJECT-TYPE
  SYNTAX	    Integer32
  UNITS         "%"
  MAX-ACCESS 	read-only
  STATUS 	    current
  DESCRIPTION 	"The percentage of total memory usage."
  ::= { afLTUStatus 5 }
  
afLTUCpuUsage OBJECT-TYPE
  SYNTAX	    Integer32
  UNITS         "%"
  MAX-ACCESS 	read-only
  STATUS 	    current
  DESCRIPTION 	"The percentage of total CPU usage."
  ::= { afLTUStatus 6 }

afLTUUptime OBJECT-TYPE
  SYNTAX	    Counter64
  UNITS       "s"
  MAX-ACCESS 	read-only
  STATUS 	    current
  DESCRIPTION 	"The uptime of the device in seconds."
  ::= { afLTUStatus 7 }

--=== AFLTU Station table

afLTUStationTable OBJECT-TYPE
  SYNTAX      SEQUENCE OF AfLTUStationEntry
  MAX-ACCESS  not-accessible
  STATUS      current
  DESCRIPTION "Remote station table for status and statistics."
  ::= { afLTUMIB 4 }

afLTUStationEntry OBJECT-TYPE
  SYNTAX      AfLTUStationEntry
  MAX-ACCESS  not-accessible
  STATUS      current
  DESCRIPTION "An entry in the afLTUStationTable"
  INDEX       { afLTUStaRemoteMac }
  ::= { afLTUStationTable 1 }

AfLTUStationEntry ::= SEQUENCE {
  afLTUStaTxRate                     INTEGER,
  afLTUStaRxRate                     INTEGER,
  afLTUStaTxCapacity                 Integer32,
  afLTUStaRxCapacity                 Integer32,
  afLTUStaRxPower0                   Integer32,
  afLTUStaRxPower1                   Integer32,
  afLTUStaIdealRxPower0              Integer32,
  afLTUStaIdealRxPower1              Integer32,
  afLTUStaRxPowerLevel0              Integer32,
  afLTUStaRxPowerLevel1              Integer32,
  afLTUStaRemoteMac                  MacAddress,
  afLTUStaRemoteDevModel             DisplayString,
  afLTUStaRemoteDevName              DisplayString,
  afLTUStaRemoteFirmwareVersion      DisplayString,
  afLTUStaRemoteTxEIRP               Integer32,
  afLTUStaRemoteRxPower0             Integer32,
  afLTUStaRemoteRxPower1             Integer32,
  afLTUStaRemoteIdealRxPower0        Integer32,
  afLTUStaRemoteIdealRxPower1        Integer32,
  afLTUStaRemoteRxPowerLevel0        Integer32,
  afLTUStaRemoteRxPowerLevel1        Integer32,
  afLTUStaRemoteLatency              Integer32,
  afLTUStaRemoteDistance             Integer32,
  afLTUStaRemoteConnectionTime       Counter64,
  afLTUStaRemoteLastIp               IpAddress,
  afLTUStaRemoteRegistrationAttempts Integer32
}

afLTUStaTxRate OBJECT-TYPE
  SYNTAX     	INTEGER
  UNITS       "x"
  MAX-ACCESS 	read-write
  STATUS 	    current
  DESCRIPTION "Current select Tx modulation"
  ::= { afLTUStationEntry 1 }

afLTUStaRxRate OBJECT-TYPE
  SYNTAX     	INTEGER
  UNITS       "x"
  MAX-ACCESS 	read-write
  STATUS 	    current
  DESCRIPTION "Current select Rx modulation"
  ::= { afLTUStationEntry 2 }

afLTUStaTxCapacity OBJECT-TYPE
  SYNTAX	    Integer32
  UNITS       "Kbps"
  MAX-ACCESS 	read-only
  STATUS 	    current
  DESCRIPTION 	"Transmit Capacity."
  ::= { afLTUStationEntry 3 }

afLTUStaRxCapacity OBJECT-TYPE
  SYNTAX	    Integer32
  UNITS       "Kbps"
  MAX-ACCESS 	read-only
  STATUS 	    current
  DESCRIPTION 	"Receive Capacity."
  ::= { afLTUStationEntry 4 }

afLTUStaRxPower0 OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Measured receive chain0 strength in dBm"
  ::= { afLTUStationEntry 5 }

afLTUStaRxPower1 OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Measured receive chain1 strength in dBm"
  ::= { afLTUStationEntry 6 }

afLTUStaIdealRxPower0 OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The ideal chain0 receive power in dBm."
  ::= { afLTUStationEntry 7 }

afLTUStaIdealRxPower1 OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The ideal chain1 receive power in dBm."
  ::= { afLTUStationEntry 8 }

afLTUStaRxPowerLevel0 OBJECT-TYPE
  SYNTAX        Integer32 (-1..100)
  UNITS         "%"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Measuared receive chain0 strength in % measured. 100% means that the measured received power is equal to the ideal power. -1 means that we are not able to get the information."
  ::= { afLTUStationEntry 9 }

afLTUStaRxPowerLevel1 OBJECT-TYPE
  SYNTAX        Integer32 (-1..100)
  UNITS         "%"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Mresuared receive chain1 strength in %. 100% means that the measured received power is equal to the ideal power. -1 means that we are not able to get the information."
  ::= { afLTUStationEntry 10 }

afLTUStaRemoteMac OBJECT-TYPE
  SYNTAX        MacAddress
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The MAC address of the remote station"
  ::= { afLTUStationEntry 11 }

afLTUStaRemoteDevModel OBJECT-TYPE
  SYNTAX        DisplayString
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The device model of the remote station"
  ::= { afLTUStationEntry 12 }

afLTUStaRemoteDevName OBJECT-TYPE
  SYNTAX        DisplayString
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The device name of the remote station."
  ::= { afLTUStationEntry 13 }

afLTUStaRemoteFirmwareVersion OBJECT-TYPE
  SYNTAX        DisplayString
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The firmware version of the remote station."
  ::= { afLTUStationEntry 14 }

afLTUStaRemoteTxEIRP OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Remote Station transmit signal strength in dBm."
  ::= { afLTUStationEntry 15 }

afLTUStaRemoteRxPower0 OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Measured receive chain0 strength in dBm at remote"
  ::= { afLTUStationEntry 16 }

afLTUStaRemoteRxPower1 OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Measured receive chain1 strength in dBm at remote"
  ::= { afLTUStationEntry 17 }

afLTUStaRemoteIdealRxPower0 OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The ideal chain0 receive power in dBm at remote."
  ::= { afLTUStationEntry 18 }

afLTUStaRemoteIdealRxPower1 OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "dBm"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "The ideal chain1 receive power in dBm at remote."
  ::= { afLTUStationEntry 19 }

afLTUStaRemoteRxPowerLevel0 OBJECT-TYPE
  SYNTAX        Integer32 (-1..100)
  UNITS         "%"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Remoate measuared receive chain0 strength in % measured. 100% means that the measured received power is equal to the ideal power. -1 means that we are not able to get the information."
  ::= { afLTUStationEntry 20 }

afLTUStaRemoteRxPowerLevel1 OBJECT-TYPE
  SYNTAX        Integer32 (-1..100)
  UNITS         "%"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Remoate measuared receive chain1 strength in % measured. 100% means that the measured received power is equal to the ideal power. -1 means that we are not able to get the information."
  ::= { afLTUStationEntry 21 }

afLTUStaRemoteLatency OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "ms"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Remote Station latency in milliseconds."
  ::= { afLTUStationEntry 22 }

afLTUStaRemoteDistance OBJECT-TYPE
  SYNTAX        Integer32
  UNITS         "km"
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Remote Station distance in kilometers."
  ::= { afLTUStationEntry 23 }

afLTUStaRemoteConnectionTime OBJECT-TYPE
  SYNTAX        Counter64
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Remote Station connection time of current session."
  ::= { afLTUStationEntry 24 }

afLTUStaRemoteLastIp OBJECT-TYPE
  SYNTAX        IpAddress
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Remote Station last known IP address."
  ::= { afLTUStationEntry 25 }

afLTUStaRemoteRegistrationAttempts OBJECT-TYPE
  SYNTAX        Integer32
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Remote Station registration attempts."
  ::= { afLTUStationEntry 26 }

--=== AFLTU Statistics

afLTUTxBytes OBJECT-TYPE
  SYNTAX        Counter64
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Total tx bytes."
  ::= { afLTUStats 1 }

afLTUTxPps OBJECT-TYPE
  SYNTAX        Integer32
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "packet per second for tx."
  ::= { afLTUStats 2 }

afLTURxBytes OBJECT-TYPE
  SYNTAX        Counter64
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "Total tx bytes."
  ::= { afLTUStats 3 }

afLTURxPps OBJECT-TYPE
  SYNTAX        Integer32
  MAX-ACCESS    read-only
  STATUS        current
  DESCRIPTION   "packet per second for rx."
  ::= { afLTUStats 4 }