-- CIENA-WS-NOTIFICATION-MIB.my
--

CIENA-WS-NOTIFICATION-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Unsigned32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, OBJECT-IDENTITY
        FROM SNMPv2-SMI
    cienaWsNotifications
        FROM CIENA-WS-MIB
    TEXTUAL-CONVENTION, TruthValue
        FROM SNMPv2-TC;

cienaWsNotificationMIB MODULE-IDENTITY
	LAST-UPDATED	"201611140000Z"
	ORGANIZATION	"Ciena Corporation"
	CONTACT-INFO
      "Web URL: http://www.ciena.com/
Postal:  7035 Ridge Road
        Hanover, Maryland 21076
        U.S.A.
Phone:   +1 800-921-1144
Fax:     +1 410-694-5750"
	DESCRIPTION
		"Notification definitions for Waveserver. Contains alarm notifications and link
state defects."
	REVISION		"201611140000Z"
	DESCRIPTION		"Added MODULE-IDENTITY statements."
	::= { cienaWsNotifications 3 }

-- Textual conventions
DisplayString32 ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "32t"
    STATUS       current
    DESCRIPTION
        "A UTF-8 string with a max length of 32 characters"
    SYNTAX       OCTET STRING(SIZE(1..32))


-- Alarm Notifications

wsAlarmNotification NOTIFICATION-TYPE
    OBJECTS {
        wsAlarmNotificationSiteId,
        wsAlarmNotificationGroupId,
        wsAlarmNotificationMemberId,
        wsAlarmNotificationInstanceId,
        wsAlarmNotificationDateAndTime,
        wsAlarmNotificationTableId,
        wsAlarmNotificationSeverity,
        wsAlarmNotificationInstance,
        wsAlarmNotificationDescription,
        wsAlarmNotificationActiveStatus,
        wsAlarmNotificationEntityType
    }
    STATUS      current
    DESCRIPTION
            "Ciena Wavesever notification for an alarm raising or clearing"
    ::= { cienaWsNotifications 11 }

wsAlarmNotificationSiteId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The system Site ID."
    ::= { wsAlarmNotification 1 }

wsAlarmNotificationGroupId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The system Group ID."
    ::= { wsAlarmNotification 2 }

wsAlarmNotificationMemberId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The system Member ID."
    ::= { wsAlarmNotification 3 }

wsAlarmNotificationInstanceId OBJECT-TYPE
    SYNTAX      Unsigned32(1..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm Instance ID."
    ::= { wsAlarmNotification 4 }

wsAlarmNotificationDateAndTime OBJECT-TYPE
    SYNTAX      DisplayString32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The local date and time when alarm was raised."
    ::= { wsAlarmNotification 5 }

wsAlarmNotificationTableId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The alarm table ID."
    ::= { wsAlarmNotification 6 }

wsAlarmNotificationSeverity OBJECT-TYPE
    SYNTAX      INTEGER {
        cleared(1),
        critical(3),
        major(4),
        minor(5),
        warning(6),
        info(8)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm severity."
    ::= { wsAlarmNotification 7 }

wsAlarmNotificationInstance OBJECT-TYPE
    SYNTAX      DisplayString32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The object instance the alarm is raised against."
    ::= { wsAlarmNotification 8 }

wsAlarmNotificationDescription OBJECT-TYPE
    SYNTAX      DisplayString32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm description."
    ::= { wsAlarmNotification 9 }

wsAlarmNotificationActiveStatus OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm active status."
    ::= { wsAlarmNotification 10 }

    -- Port Type
wsAlarmNotificationEntityType OBJECT-TYPE
    SYNTAX      INTEGER {
        notApplicable(0),
        other(1),
        clientPort(2),
        linePort(3)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm source entity type if applicable."
    ::= { wsAlarmNotification 11 }

-- Link state notifications
-- The following notification communicates the state of a link. This includes
-- detailed information about the current health of the link.
wsLinkStateAlarmNotification NOTIFICATION-TYPE
    OBJECTS {
        wsLinkStateAlarmNotificationSiteId,
        wsLinkStateAlarmNotificationGroupId,
        wsLinkStateAlarmNotificationMemberId,
        wsLinkStateAlarmNotificationInstanceId,
        wsLinkStateAlarmNotificationDateAndTime,
        wsLinkStateAlarmNotificationSeverity,
        wsLinkStateAlarmNotificationInstance,
        wsLinkStateAlarmNotificationDescription,
        wsLinkStateAlarmNotificationPtpRxLos,
        wsLinkStateAlarmNotificationPtpRxLol,
        wsLinkStateAlarmNotificationPtpTxLos,
        wsLinkStateAlarmNotificationPtpTxLol,
        wsLinkStateAlarmNotificationEthFecLossSync,
        wsLinkStateAlarmNotificationEthEBer,
        wsLinkStateAlarmNotificationEthRsLf,
        wsLinkStateAlarmNotificationEthRsRf,
        wsLinkStateAlarmNotificationEthPcsLobl,
        wsLinkStateAlarmNotificationEthPcsLoam,
        wsLinkStateAlarmNotificationEthPcsLol,
        wsLinkStateAlarmNotificationEthRsLinkDown,
        wsLinkStateAlarmNotificationOtuLoc,
        wsLinkStateAlarmNotificationOtuFreqOor,
        wsLinkStateAlarmNotificationOtuLof,
        wsLinkStateAlarmNotificationOtuPreFecSf,
        wsLinkStateAlarmNotificationOtuPreFecSd,
        wsLinkStateAlarmNotificationOtuLom,
        wsLinkStateAlarmNotificationOtuBdi,
        wsLinkStateAlarmNotificationOtuTtiMismatch,
        wsLinkStateAlarmNotificationOduOci,
        wsLinkStateAlarmNotificationOduAis,
        wsLinkStateAlarmNotificationOduLck,
        wsLinkStateAlarmNotificationOduSf,
        wsLinkStateAlarmNotificationOduSd,
        wsLinkStateAlarmNotificationOduTtiMismatch,
        wsLinkStateAlarmNotificationOduBdi,
        wsLinkStateAlarmNotificationOduPtiMismatch,
        wsLinkStateAlarmNotificationOduFeClientSf,
        wsLinkStateAlarmNotificationOduSkewOor,
        wsLinkStateAlarmNotificationEntityType
    }
    STATUS        current
    DESCRIPTION
        "Ciena Waveserver notification for line faults."
    ::= { cienaWsNotifications 12 }

wsLinkStateAlarmNotificationSiteId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The line fault site ID."
    ::= { wsLinkStateAlarmNotification 1 }

wsLinkStateAlarmNotificationGroupId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The system Group ID."
    ::= { wsLinkStateAlarmNotification 2 }

wsLinkStateAlarmNotificationMemberId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The system Member ID."
    ::= { wsLinkStateAlarmNotification 3 }

wsLinkStateAlarmNotificationInstanceId OBJECT-TYPE
    SYNTAX      Unsigned32(1..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The line fault instance ID."
    ::= { wsLinkStateAlarmNotification 4 }

wsLinkStateAlarmNotificationDateAndTime OBJECT-TYPE
    SYNTAX      DisplayString32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The local date and time when alarm was raised."
    ::= { wsLinkStateAlarmNotification 5 }

wsLinkStateAlarmNotificationSeverity OBJECT-TYPE
    SYNTAX      INTEGER {
        cleared(1),
        critical(3),
        major(4),
        minor(5),
        warning(6),
        info(8)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm severity."
    ::= { wsLinkStateAlarmNotification 7 }

wsLinkStateAlarmNotificationInstance OBJECT-TYPE
    SYNTAX      DisplayString32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The object instance the alarm is raised against."
    ::= { wsLinkStateAlarmNotification 8 }

wsLinkStateAlarmNotificationDescription OBJECT-TYPE
    SYNTAX      DisplayString32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm description."
    ::= { wsLinkStateAlarmNotification 9 }


    -- PTP
wsLinkStateAlarmNotificationPtpDefects OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "Defects related to the physical termination point."
    ::= { wsLinkStateAlarmNotification 10 }


wsLinkStateAlarmNotificationPtpRxLos OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP alarms for the link."
    ::= { wsLinkStateAlarmNotificationPtpDefects 1 }

wsLinkStateAlarmNotificationPtpRxLol OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP alarms for the link."
    ::= { wsLinkStateAlarmNotificationPtpDefects 2 }

wsLinkStateAlarmNotificationPtpTxLos OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP alarms for the link."
    ::= { wsLinkStateAlarmNotificationPtpDefects 3 }

wsLinkStateAlarmNotificationPtpTxLol OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP alarms for the link."
    ::= { wsLinkStateAlarmNotificationPtpDefects 4 }

-- Ethernet alarms
wsLinkStateAlarmNotificationEthDefects OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "Ethernet defects."
    ::= { wsLinkStateAlarmNotification 11 }

wsLinkStateAlarmNotificationEthPcsHighBer OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Ethernet PCS high bit error rate."
    ::= { wsLinkStateAlarmNotificationEthDefects 1 }

wsLinkStateAlarmNotificationEthPcsLoam OBJECT-TYPE
    SYNTAX      INTEGER { inactive(0), active(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Ethernet PCS loss of alignment marker."
    ::= { wsLinkStateAlarmNotificationEthDefects 2 }

wsLinkStateAlarmNotificationEthPcsLobl OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Ethernet PCS loss of block lock."
    ::= { wsLinkStateAlarmNotificationEthDefects 3 }

wsLinkStateAlarmNotificationEthRsLinkDown OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Ethernet RS link down."
    ::= { wsLinkStateAlarmNotificationEthDefects 4 }

wsLinkStateAlarmNotificationEthRsLf OBJECT-TYPE
    SYNTAX      INTEGER { inactive(0), active(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Ethernet RS local fault."
    ::= { wsLinkStateAlarmNotificationEthDefects 5 }

wsLinkStateAlarmNotificationEthRsRf OBJECT-TYPE
    SYNTAX      INTEGER { inactive(0), active(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Ethernet RS remote fault."
    ::= { wsLinkStateAlarmNotificationEthDefects 6 }

wsLinkStateAlarmNotificationEthFecLossSync OBJECT-TYPE
    SYNTAX      INTEGER { inactive(0), active(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Ethernet FEC loss of alignment marker."
    ::= { wsLinkStateAlarmNotificationEthDefects 7 }

wsLinkStateAlarmNotificationEthPmaSool OBJECT-TYPE
    SYNTAX      INTEGER { inactive(0), active(1) }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Ethernet PMA serdes out of lock."
    ::= { wsLinkStateAlarmNotificationEthDefects 8 }


-- OTU Alarms

wsLinkStateAlarmNotificationOtuDefects OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "OTU layer defects."
    ::= { wsLinkStateAlarmNotification 12 }


wsLinkStateAlarmNotificationOtuLoc OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OTU loss of clock."
    ::= { wsLinkStateAlarmNotificationOtuDefects 1}

wsLinkStateAlarmNotificationOtuFreqOor OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OTU frequency out of range."
    ::= { wsLinkStateAlarmNotificationOtuDefects 2 }

wsLinkStateAlarmNotificationOtuLof OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OTU loss of frame."
    ::= { wsLinkStateAlarmNotificationOtuDefects 3 }

wsLinkStateAlarmNotificationOtuPreFecSf OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OTU pre-FEC signal fail."
    ::= { wsLinkStateAlarmNotificationOtuDefects 4 }

wsLinkStateAlarmNotificationOtuPreFecSd OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OTU pre-FEC signal degrade."
    ::= { wsLinkStateAlarmNotificationOtuDefects 5 }

wsLinkStateAlarmNotificationOtuLom OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OTU loss of multi-frame."
    ::= { wsLinkStateAlarmNotificationOtuDefects 6 }

wsLinkStateAlarmNotificationOtuBdi OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OTU backwards defect indicator."
    ::= { wsLinkStateAlarmNotificationOtuDefects 7 }

wsLinkStateAlarmNotificationOtuTtiMismatch OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "OTU TTI mismatch."
    ::= { wsLinkStateAlarmNotificationOtuDefects 8 }

-- ODU
wsLinkStateAlarmNotificationOduDefects OBJECT-IDENTITY
    STATUS      current
    DESCRIPTION
        "ODU layer defects."
    ::= { wsLinkStateAlarmNotification 13 }

wsLinkStateAlarmNotificationOduOci OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU open connection indication."
    ::= { wsLinkStateAlarmNotificationOduDefects 1 }

wsLinkStateAlarmNotificationOduAis OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU alarm indicating signal."
    ::= { wsLinkStateAlarmNotificationOduDefects 2 }

wsLinkStateAlarmNotificationOduLck OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU locked."
    ::= { wsLinkStateAlarmNotificationOduDefects 3 }

wsLinkStateAlarmNotificationOduSf OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU signal fail."
    ::= { wsLinkStateAlarmNotificationOduDefects 4 }

wsLinkStateAlarmNotificationOduSd OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU signal degrade."
    ::= { wsLinkStateAlarmNotificationOduDefects 5 }

wsLinkStateAlarmNotificationOduTtiMismatch OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU TTI mismatch."
    ::= { wsLinkStateAlarmNotificationOduDefects 6 }

wsLinkStateAlarmNotificationOduBdi OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU backwards defect indicator."
    ::= { wsLinkStateAlarmNotificationOduDefects 7 }

wsLinkStateAlarmNotificationOduPtiMismatch OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU payload type indicator mismatch."
    ::= { wsLinkStateAlarmNotificationOduDefects 8 }

wsLinkStateAlarmNotificationOduFeClientSf OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU far-end client signal fail."
    ::= { wsLinkStateAlarmNotificationOduDefects 9 }

wsLinkStateAlarmNotificationOduSkewOor OBJECT-TYPE
    SYNTAX      INTEGER {
        inactive(0),
        active(1)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "ODU skew out of range."
    ::= { wsLinkStateAlarmNotificationOduDefects 10 }

wsLinkStateAlarmNotificationEntityType OBJECT-TYPE
    SYNTAX      INTEGER {
        notApplicable(0),
        other(1),
        clientPort(2),
        linePort(3)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The alarm source entity type if applicable."
    ::= { wsLinkStateAlarmNotification 14 }

END