-- company power MIB

--
-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) company(2111)
-- products(1) ups(1)
--
-- ==============================================================================================


companyMIB DEFINITIONS ::= BEGIN

IMPORTS
  enterprises 
     FROM RFC1155-SMI
  MODULE-IDENTITY, OBJECT-TYPE,  OBJECT-IDENTITY
     FROM SNMPv2-SMI
  DisplayString
     FROM SNMPv2-TC
  TRAP-TYPE
     FROM RFC-1215
  PositiveInteger,  NonNegativeInteger
     FROM UPS-MIB;
  

  companyMIB MODULE-IDENTITY
       LAST-UPDATED "201005060000Z"
       ORGANIZATION "company Power Technology"
       CONTACT-INFO  " "
              
       DESCRIPTION
               "The MIB module to describe UPS"


  
       ::= { enterprises 21111 }



products        OBJECT IDENTIFIER ::= { companyMIB   1 }
ups             OBJECT IDENTIFIER ::= { products 1 }
inverter        OBJECT IDENTIFIER ::= { products 2 }
charger         OBJECT IDENTIFIER ::= { products 3 }
ATS             OBJECT IDENTIFIER ::= { products 4 }

upsIdent        OBJECT IDENTIFIER ::= { ups 1 }
upsRating       OBJECT IDENTIFIER ::= { ups 2 }
upsBattery      OBJECT IDENTIFIER ::= { ups 3 }
upsInput        OBJECT IDENTIFIER ::= { ups 4 }
upsOutput       OBJECT IDENTIFIER ::= { ups 5 }
upsBypass       OBJECT IDENTIFIER ::= { ups 6 }
upsTest         OBJECT IDENTIFIER ::= { ups 7 }
upsControl      OBJECT IDENTIFIER ::= { ups 8 }
agentConfig     OBJECT IDENTIFIER ::= { ups 9 }
commConfig      OBJECT IDENTIFIER ::= { ups 10 }
upsConfig       OBJECT IDENTIFIER ::= { ups 11 }
upsTraps        OBJECT IDENTIFIER ::= { ups 12 }
extend          OBJECT IDENTIFIER ::= { ups 13 }

solarIdent        OBJECT IDENTIFIER ::= { inverter 1 }
solarRating       OBJECT IDENTIFIER ::= { inverter 2 }
solarBattery      OBJECT IDENTIFIER ::= { inverter 3 }
solarGrid         OBJECT IDENTIFIER ::= { inverter 4 }
solarACOutput     OBJECT IDENTIFIER ::= { inverter 5 }
solarPV           OBJECT IDENTIFIER ::= { inverter 6 }
solarEnergy       OBJECT IDENTIFIER ::= { inverter 7 }
solarTest         OBJECT IDENTIFIER ::= { inverter 8 }
solarDefValue     OBJECT IDENTIFIER ::= { inverter 9 }
solarFaultInfo    OBJECT IDENTIFIER ::= { inverter 10 }
solarControl      OBJECT IDENTIFIER ::= { inverter 11 }
solarAgentConfig  OBJECT IDENTIFIER ::= { inverter 12 }
solarCommConfig   OBJECT IDENTIFIER ::= { inverter 13 }
solarConfig       OBJECT IDENTIFIER ::= { inverter 14 }
solarTraps        OBJECT IDENTIFIER ::= { inverter 15 }
solarExtend       OBJECT IDENTIFIER ::= { inverter 16 }


ATSIdent        OBJECT IDENTIFIER ::= { ATS 1 }
ATSRating       OBJECT IDENTIFIER ::= { ATS 2 }
ATSInformation  OBJECT IDENTIFIER ::= { ATS 3 }
ATSControl      OBJECT IDENTIFIER ::= { ATS 4 }
ATSAgentConfig  OBJECT IDENTIFIER ::= { ATS 5 }
ATSCommConfig   OBJECT IDENTIFIER ::= { ATS 6 }
ATSConfig       OBJECT IDENTIFIER ::= { ATS 7 }
ATSTraps        OBJECT IDENTIFIER ::= { ATS 8 }
ATSExtend       OBJECT IDENTIFIER ::= { ATS 9 }

---=======================================================
---upsIdent 
--- prefix =upsId
---========================================================

upsIdManufacturer OBJECT-TYPE
       SYNTAX     DisplayString (SIZE (0..31))
       ACCESS read-only
       STATUS     mandatory
       DESCRIPTION
           "The name of the UPS manufacturer."
       ::= { upsIdent 1 }

upsIdProtocol OBJECT-TYPE
      SYNTAX INTEGER {
         unknown(-1),
         pmv(99),
         p00(0),
         p01(1),
         p02(2),
         p03(3),
         p04(4),
         p05(5),
         p06(6),
         p07(7),
         p08(8),
         p09(9),
         p10(10),
  sec(80)
     }
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
          "The UPS Protocol id."
      ::= { upsIdent 2 }

upsIdModelName OBJECT-TYPE
       SYNTAX     DisplayString (SIZE (0..15))
       ACCESS read-only
       STATUS     mandatory
       DESCRIPTION
     "The UPS Model designation."
      ::= { upsIdent 3 }

upsIdSerialNumber OBJECT-TYPE
      SYNTAX DisplayString (SIZE(0..31))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
          "The UPS serial no."
      ::= { upsIdent 4 }

upsIdName OBJECT-TYPE
       SYNTAX     DisplayString (SIZE(0..31))
       ACCESS read-write
       STATUS     mandatory
       DESCRIPTION
               "A string identifying the UPS.  This object should be
               set by the administrator."
       ::= { upsIdent 5 }

upsIdFWVersion OBJECT-TYPE
       SYNTAX     DisplayString (SIZE(0..31))
       ACCESS read-only
       STATUS     mandatory
       DESCRIPTION
               "Main CPU firmware version."
       ::= { upsIdent 6 }


upsIdUPSType OBJECT-TYPE
     SYNTAX     INTEGER {
           standy(0),
           line-interactive(1),
           on-line(2)
     }
       ACCESS read-only
       STATUS     mandatory
       DESCRIPTION
               "UPS type."
       ::= { upsIdent 7 }
--===========================================================================
--upsRating 
--prefix =upsRat
--the rating info of ups
--==========================================================================
upsRatinVoltage OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 Volt DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The rating input voltage of UPS"
    ::= { upsRating 1 }

upsRatoutVoltage OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 Volt DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The rating output voltage of UPS"
    ::= { upsRating 2 }

upsRatoutFrequency OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 HZ"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The rating output frequency of UPS"
    ::= { upsRating 3 }

upsRatoutCurrent OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The rating output current of UPS"
    ::= { upsRating 4 }

upsRatoutApparentPower OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 VA"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The rating output apparent power of UPS"
    ::= { upsRating 5 }

upsRatoutTruePower OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 Wt"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The rating output true power of UPS"
    ::= { upsRating 6 }

upsRatBatVoltage OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 vol"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The rating battery voltage of UPS"
    ::= { upsRating 7 }



-- ===========================================================================
-- upsBattery   
-- prefix = upsBat
-- The Battery group.
-- est=estimated
-- ===========================================================================

upsBatStatus OBJECT-TYPE
     SYNTAX     INTEGER {
           unknown(1),
           batteryNormal(2),
           batteryLow(3),
           batteryDepleted(4),
           batteryDischarging(5),
           batteryFailure(6),
           batteryReplace(7),
    batterysilence(8)
     }
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
               "The indication of the status in the UPS system's batteries."
     ::= { upsBattery 1 }



upsBatSecondsOnBattery OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "seconds"
     ACCESS read-only
     STATUS current
     DESCRIPTION
        "If the unit is on battery power, the elapsed time
        since the UPS last switched to battery power, or the
        time since the network management subsystem was last
        restarted, whichever is less.  -1 shall be returned
        if the unit is not on battery power."
     ::= { upsBattery 2 }

upsBatEstMinutesRemaining OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "minutes"
     ACCESS read-only
     STATUS current
     DESCRIPTION
        "An estimate of the time to battery charge depletion
        under the present load conditions if the utility power
        is off and remains off, or if it were to be lost and
        remain off."
     ::= { upsBattery 3 }

upsBatEstChargeRemaining OBJECT-TYPE
    SYNTAX     INTEGER (0..100)
    UNITS      "percent"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "An estimate of the battery charge remaining expressed
            as a percent of full charge."
    ::= { upsBattery 4 }

upsBatPBatVoltage OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 Volt DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The magnitude of the  present Positive battery voltage."
    ::= { upsBattery 5 }


upsBatNBatVoltage OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    UNITS      "0.1 Volt DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The magnitude of the present negative battery voltage."
    ::= { upsBattery 6 }

upsBatPBatCurrent OBJECT-TYPE
    SYNTAX     INTEGER
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The positive battery present  current."
    ::= { upsBattery 7 }

upsBatNBatCurrent OBJECT-TYPE
    SYNTAX     INTEGER
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The present negative battery current."
    ::= { upsBattery 8 }

upsBatPBatChargCurrent OBJECT-TYPE
    SYNTAX   INTEGER
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The Positive battery charging  current."
    ::= { upsBattery 9 }

upsBatNBatchargCurrent OBJECT-TYPE
    SYNTAX     INTEGER
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The present negative battery charging  current."
    ::= { upsBattery 10 }

upsBatPBatDischargCurrent OBJECT-TYPE
    SYNTAX     INTEGER
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The present positive battery discharging current."
    ::= { upsBattery 11 }

upsBatNBatDischargCurrent OBJECT-TYPE
    SYNTAX     INTEGER
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The present negative battery discharging current."
    ::= { upsBattery 12 }

upsBatTemperature OBJECT-TYPE
    SYNTAX     INTEGER
    UNITS      "degrees 0.1 Centigrade"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The ambient temperature at or near the UPS Battery
            casing."
    ::= { upsBattery 13 }

upsBatNumberInSeries OBJECT-TYPE
   SYNTAX     PositiveInteger
   ACCESS read-only
   STATUS     current
   DESCRIPTION
            "The number of battery in series."
    ::= { upsBattery 14 }


upsBatNumberInParallel OBJECT-TYPE
   SYNTAX     PositiveInteger
   ACCESS read-only
   STATUS     current
   DESCRIPTION
            "The number of battery in Parallel."
    ::= { upsBattery 15 }

upsBatPBatDischargCurrent2 OBJECT-TYPE
    SYNTAX     INTEGER
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The present positive battery pipe2 discharging current."
    ::= { upsBattery 16 }

-- ===========================================================================
-- upsInput
-- prefix = upsIn
-- Input group.
-- ===========================================================================

upsInLineBads OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "A count of the number of times the input entered an
            out-of-tolerance condition as defined by the
            manufacturer.  This count is incremented by one each
            time the input transitions from zero out-of-tolerance
            lines to one or more input lines out-of-tolerance."
    ::= { upsInput 1 }


upsInTtlApparentPower OBJECT-TYPE
    SYNTAX NonNegativeInteger
    UNITS     "0.1VA"   
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "Total input apparent power ."
    ::= { upsInput 2 }

upsInTtlTruePower OBJECT-TYPE
    SYNTAX NonNegativeInteger
    UNITS     "0.1WT"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "Total input active(true) power ."
    ::= { upsInput 3 }



upsInNumLines OBJECT-TYPE
    SYNTAX     NonNegativeInteger
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "The number of input lines utilized in this device.
            This variable indicates the number of rows in the
            input table."
    ::= { upsInput 4 }


upsInTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsInEntry 
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "A list of input table entries.  The number of entries
         is given by the value of upsInputNumLines."
    ::= { upsInput  5 }


upsInTtlVoltage OBJECT-TYPE
    SYNTAX INTEGER
     UNITS      "0.1 Volts"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The input utility line tatol voltage ."
    ::= { upsInput 6 }

upsInTtlCurrent OBJECT-TYPE
    SYNTAX INTEGER
     UNITS      "0.1 A"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The input utility line tatol current."
    ::= { upsInput 7 }

upsInEntry OBJECT-TYPE
    SYNTAX  UpsInEntry
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "An entry containing information applicable to a
         particular input line."
    INDEX { upsInLineIndex    }
    ::= { upsInTable  1 }

UpsInEntry ::=
    SEQUENCE {
             upsInLineIndex      PositiveInteger,
             upsInFrequency      NonNegativeInteger,
             upsInVoltage        NonNegativeInteger,
             upsInCurrent        NonNegativeInteger,
             upsInApparentPower  NonNegativeInteger,
             upsInTruePower      NonNegativeInteger,
             upsInPowerFactor    NonNegativeInteger,
             upsInLineVoltage    NonNegativeInteger
             }

upsInLineIndex OBJECT-TYPE
     SYNTAX INTEGER (0..10)
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The number of output lines"
     ::= { upsInEntry 1 }

upsInFrequency OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS      "0.1 Hertz"
       ACCESS read-only
       STATUS     current
       DESCRIPTION
               "The present input frequency."
       ::= { upsInEntry 2 }

upsInVoltage OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Volts"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The input utility line voltage ."
     ::= { upsInEntry 3 }

upsInCurrent OBJECT-TYPE
     SYNTAX INTEGER
     UNITS   "0.1Amp"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The magnitude of the present input current "
     ::= { upsInEntry 4 }


  
upsInApparentPower OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS     "0.1VA"
       ACCESS read-only
       STATUS     current
       DESCRIPTION
               "The magnitude of the present input Apparent power."
       ::= { upsInEntry 5 }


upsInTruePower OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS     "0.1Watts"
       ACCESS read-only
       STATUS     current
       DESCRIPTION
               "The magnitude of the present input true power."
       ::= { upsInEntry 6 }



upsInPowerFactor OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS     "0.01"
       ACCESS read-only
       STATUS     current
       DESCRIPTION
               "Input  true power/apparent power factor "
       ::= { upsInEntry 7 }

upsInLineVoltage OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Volts"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The input utility line voltage .
     if upsInLineIndex =1, upsInLineVoltage = Line voltage of RS phase;
     if upsInLineIndex =2, upsInLineVoltage = Line voltage of ST phase;
     if upsInLineIndex =3, upsInLineVoltage = Line voltage of TR phase."
     ::= { upsInEntry 8 }

-- ===========================================================================
-- upsOutput
-- prefix= upsOut
-- Output group
-- ===========================================================================

upsOutSource OBJECT-TYPE
     SYNTAX     INTEGER {
           other(1),
           none(2),
           normal(3),
           bypass(4),
           battery(5),
           booster(6),
           reducer(7),
           batterytest(8),
           fault(9),
           HE-ECOmode(10),
           convertermode(11)
     }
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The present source of output power.  The enumeration
             none(2) indicates that there is no source of output
             power (and therefore no output power), for example,
             the system has opened the output breaker.==UPS standby mode"
     ::= { upsOutput 1 }

upsOutFrequency OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Hertz"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The current output frequency of the UPS system "
     ::= { upsOutput 2 }


upsOutTtlApparentPower OBJECT-TYPE
    SYNTAX NonNegativeInteger
    UNITS     "0.1VA"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "Total output apparent power ."
    ::= { upsOutput 3 }

upsOutTtlTruePower OBJECT-TYPE
    SYNTAX NonNegativeInteger
    UNITS     "0.1Watts"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "Total output active(true) power ."
    ::= { upsOutput 4 }


upsOutTtlPercentLoad OBJECT-TYPE
     SYNTAX INTEGER (0..100)
     UNITS      "percent"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The percentage of the UPS power capacity presently
             being used on this output line, i.e., the greater of
             the percent load of true power capacity and the
             percent load of VA."
     ::= { upsOutput 5 }




upsOutNumLines OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The number of output lines utilized in this device.
          This variable indicates the number of rows in the
          output table."
     ::= { upsOutput 6 }

upsOutTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsOutEntry 
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "A list of output table entries.  The number of
         entries is given by the value of upsOutputNumLines."
    ::= { upsOutput  7 }


upsOutTtlVoltage OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1vot"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "Total output voltage ."
     ::= { upsOutput 8 }

upsOutTtlCurrent OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1A"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "Total output current."
     ::= { upsOutput 9 }

upsOutStatus OBJECT-TYPE
     SYNTAX DisplayString (SIZE (4..4))
     ACCESS read-only
     STATUS current
     DESCRIPTION
         " For HVDC device.
                 char status[4];
     status[0]status[1]:00, no output1; 01, line output1; 02, bat output1
                 status[2]status[3]:00, no output2; 01, line output2; 02, bat output2
        "
     ::= { upsOutput 10 }



upsOutSource2 OBJECT-TYPE
     SYNTAX     INTEGER {
           other(1),
           none(2),
           normal(3),
           bypass(4),
           battery(5),
           booster(6),
           reducer(7),
           batterytest(8),
           fault(9),
           HE-ECOmode(10),
           convertermode(11)
     }
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "For HVDC(protocol:P12) machine.  The present source of output power.  The enumeration
             none(2) indicates that there is no source of output
             power (and therefore no output power), for example,
             the system has opened the output breaker.==UPS standby mode"
     ::= { upsOutput 11 }


upsOutEntry OBJECT-TYPE
    SYNTAX  UpsOutEntry 
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "An entry containing information applicable to a
         particular output line."
    INDEX { upsOutLineIndex      }
    ::= { upsOutTable  1 }

UpsOutEntry ::=
    SEQUENCE {
             upsOutLineIndex      PositiveInteger,
             upsOutVoltage        NonNegativeInteger,
             upsOutCurrent        NonNegativeInteger,
             upsOutApparentPower  NonNegativeInteger,
             upsOutTruePower      NonNegativeInteger, 
             upsOutPowerFactor    NonNegativeInteger,
             upsOutPercentLoad    INTEGER,
             upsOutLineVoltage    NonNegativeInteger
             }

upsOutLineIndex OBJECT-TYPE
     SYNTAX INTEGER (0..10)
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The output line identifier."
     ::= { upsOutEntry 1 }

upsOutVoltage OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Volts"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The output voltage of the UPS system."
     ::= { upsOutEntry 2 }

upsOutCurrent OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Amp"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The output current of the UPS system"
     ::= { upsOutEntry 3 }

upsOutApparentPower OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS     "0.1VA"
       ACCESS    read-only
       STATUS     current
       DESCRIPTION
               "The present output apparent power."
       ::= { upsOutEntry 4 }

upsOutTruePower OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS   "0.1Watts"
       ACCESS read-only
       STATUS     current
       DESCRIPTION
               "The present output true power."
      ::= { upsOutEntry 5 }

upsOutPowerFactor OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS     "0.01"
       ACCESS read-only
       STATUS     current
       DESCRIPTION
               "Output true power/apparent power factor "
       ::= { upsOutEntry 6 }

upsOutPercentLoad OBJECT-TYPE
     SYNTAX INTEGER (0..100)
     UNITS      "percent"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The percentage of the UPS power capacity presently
             being used on this output line, i.e., the greater of
             the percent load of true power capacity and the
             percent load of VA."
     ::= { upsOutEntry 7 }

upsOutLineVoltage OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Volts"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The output line voltage of the UPS system.
            if upsOutLineIndex =1, upsOutLineVoltage = Line voltage of RS phase;
     if upsOutLineIndex =2, upsOutLineVoltage = Line voltage of ST phase;
     if upsOutLineIndex =3, upsOutLineVoltage = Line voltage of TR phase."
     ::= { upsOutEntry 8 }

upsOutFrequency OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS     "0.1Hertz"
       ACCESS read-only
       STATUS     current
       DESCRIPTION
               "The present output frequency."
       ::= { upsOutEntry 9 }

-- ===========================================================================
-- upsBypass
-- prefix =upsBy
-- ===========================================================================

upsByFrequency OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Hertz"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The present bypass frequency."
     ::= { upsBypass 1 }



upsByNumLines OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The number of bypass lines utilized in this device.
             This entry indicates the number of rows in the bypass
             table."
     ::= { upsBypass 2 }


upsByTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsByEntry 
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "A list of bypass table entries.  The number of
         entries is given by the value of upsBypassNumLines."
    ::= { upsBypass  3 }

upsByEntry OBJECT-TYPE
    SYNTAX  UpsByEntry 
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
           "An entry containing information applicable to a
               particular bypass input."
    INDEX { upsByLineIndex }
    ::= { upsByTable  1 }

UpsByEntry ::=
    SEQUENCE {
             upsByLineIndex          PositiveInteger,
             upsByVoltage            NonNegativeInteger,
             upsByCurrent            NonNegativeInteger,
             upsByPower              NonNegativeInteger,
      upsByLineVoltage        INTEGER
             }

upsByLineIndex OBJECT-TYPE
     SYNTAX INTEGER (0..65535)
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The bypass line identifier."
     ::= { upsByEntry 1 }

upsByVoltage OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Volts"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The present bypass voltage."
     ::= { upsByEntry 2 }

upsByCurrent OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 RMS Amp"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The present bypass current."
     ::= { upsByEntry 3 }

upsByPower OBJECT-TYPE
       SYNTAX     NonNegativeInteger
       UNITS      "0.1Watts"
       ACCESS read-only
       STATUS     current
       DESCRIPTION
               "The present true power conveyed by the bypass."
       ::= { upsByEntry 4 }

upsByLineVoltage OBJECT-TYPE
     SYNTAX INTEGER
     UNITS      "0.1 Volts"
     ACCESS read-only
     STATUS current
     DESCRIPTION
         "The present bypass line voltage.
     if upsByLineIndex=1,upsByLineVoltage=Line voltage of RS phase;
     if upsByLineIndex=2,upsByLineVoltage=Line voltage of ST phase;
     if upsByLineIndex=3,upsByLineVoltage=Line voltage of TR phase."
     ::= { upsByEntry 5 }

-- ===========================================================================
-- upsTest
-- prefix=upsTst
-- ===========================================================================


upsTstBatteryTest OBJECT-TYPE
        SYNTAX INTEGER {
            none(1),
            battTest10sec(2),
            battTestUntilLow(3),
            battTestWithTime(4),       
            battTestCancelTest(5),
            battTestClearInfo(6)
            
        }
        ACCESS read-write
        STATUS current
        DESCRIPTION
                "This object specify the battery test type and initiate
                 battery test. If battTestWithTime selected, the test
                 time is refer to upsTestBatteryTestTime."
     ::= { upsTest 1 }

upsTstBatteryTestResult OBJECT-TYPE
        SYNTAX  INTEGER {
                donePassed(1),
                doneWarning(2),
                doneError(3),
                aborted(4),
                inProgress(5),
                noTestsInitiated(6)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
         "The results of the current or last UPS diagnostics
               test performed.  The values for donePassed(1),
               doneWarning(2), and doneError(3) indicate that the
               test completed either successfully, with a warning, or
               with an error, respectively.  The value aborted(4) is
               returned for tests which are aborted by setting the
               value of upsTestId to upsTestAbortTestInProgress.
               Tests which have not yet concluded are indicated by
               inProgress(5).  The value noTestsInitiated(6)
               indicates that no previous test results are available,
               such as is the case when no tests have been run since
               the last reinitialization of the network management
               subsystem and the system has no provision for non-
               volatile storage of test results."
     ::= { upsTest 2 }



upsTstBatteryTestStartTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE(19..19))
        ACCESS read-only
        STATUS current
        DESCRIPTION
         "The value of the time the test in progress was initiated,
          or, if no test is in progress, the time the previous test
          was initiated. If the value of upsTestBatteryTestResult
          is noTestsInitiated(6), upsTestStartTime has the value
          01/01/1970 00:00:00. format is (MM/DD/YYYY hh:mm:ss)"
     ::= { upsTest 3 }


upsTstBatterySettingTime OBJECT-TYPE
        SYNTAX INTEGER (12..5940)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The object specify the test time for battery test, the unit is seconds"
     ::= { upsTest 4 }

     --below 1 minute 0.2-1.0  ,larger than 1 minutes ,1,2,3..99;

-- ===========================================================================
-- upsControl
-- prefix=upsCtl
-- ===========================================================================


upsCtlShutdownDelay OBJECT-TYPE
        SYNTAX INTEGER (-2..2147483648)
        UNITS "seconds" 
        ACCESS read-write
        STATUS current
        DESCRIPTION
                "The delay in seconds the UPS remains on after being told
                 to turn off. if value=-2 cancel shutdown, if value=-1 donothing,
                 value=0 shutdown ups immediately"
        ::= { upsControl 1 }


upsCtlSleepTime OBJECT-TYPE
        SYNTAX INTEGER (-1..2147483648)
        UNITS "minutes"
        ACCESS read-write
        STATUS current
        DESCRIPTION
                "The time in minutes for the UPS to go to sleep  when
                 instructed.  When in sleep mode, the UPS will not provide
                 output power regardless of the input line state.  Once the
                 specified time has elapsed, output power will be restored.

                 This is a configuration setting.  The UPS will not go to
                 sleep until told to do so by the manager from a management
                 station.

                 Any input value is allowed, however the UPS only recognizes
                 0 - 9999 minutes in one minute increments.

                 If the provided value is higher than the highest acceptable
                 value, the highest acceptable value is used."
        ::= { upsControl 2 }

upsCtlStartupAfterDelay OBJECT-TYPE
    SYNTAX     INTEGER (-1..2147483648)
    UNITS      "seconds"
    ACCESS read-write
    STATUS     current
    DESCRIPTION
            "Setting this object will start the output after the
            indicated number of seconds, including starting the
            UPS, if necessary.  -1 mean not startup.  
            must set  upsCtlStartupAfterDelay before  upsCtlShutdownDelay ,
     the value must larger than 59 if the value not equal -1 "
            
    ::= { upsControl 3 }



upsCtlbuzzer OBJECT-TYPE
   SYNTAX INTEGER {
     on(1),
     off(2)
   }
   ACCESS read-write
   STATUS     current
   DESCRIPTION 
      "Setting this object to 'on' or 'off' to enable or disable buzzer"

   ::= { upsControl 4 }



upsCtlRemoteControlUPS OBJECT-TYPE
   SYNTAX INTEGER {
      on(1),
      off(2)
    }
   ACCESS read-write
   STATUS current
   DESCRIPTION
       "Setting this object to turn 'on' or 'off' UPS " 

  ::= { upsControl 5 }

upsCtloutletPoweron OBJECT-TYPE
   SYNTAX INTEGER (1..2)
   ACCESS write-only
   STATUS current
   DESCRIPTION 
      "Setting this object to 1 means 1st outlet,2  means 2nd outlet , immediately process"

    ::= { upsControl 6 }
    


upsCtloutletPoweroff OBJECT-TYPE
   SYNTAX INTEGER (1..2)
   ACCESS write-only
   STATUS current
   DESCRIPTION
      "Setting this object to  1 means 1st outlet,
 2   means 2nd outlet , immediately process"

    ::= { upsControl 7 }


upsCtlOutlet1Powerofftime OBJECT-TYPE
   SYNTAX INTEGER (-1..999)
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "setting this object to -1 means this control not effect,
 0 means immediately  process,
 >0 means wait times unit is  minutes 
      use in battery mode"    
    ::= { upsControl 8 }

upsCtlOutlet2Powerofftime OBJECT-TYPE
   SYNTAX INTEGER (-1..999)
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "setting this object to -1 means this control not effect,
       0 means immediately  process ,
       >0 means wait times unit is minutes  .use in battery mode"    
    ::= { upsControl 9 }

upsCtlResetConfigure OBJECT-TYPE
   SYNTAX INTEGER {
     none(0),
     reset(1)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
      " reset all configure para to default."
    ::= { upsControl 10 }


--===========================================================================
--
-- agentConfig
-- prefix=agent
-- ===========================================================================


agentConfigDatetime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (19..19))
        ACCESS read-write
        STATUS current
        DESCRIPTION
                "The datetime in agent, format is (MM/DD/YYYY hh:mm:ss)"
        ::= { agentConfig 1 }




---======================================================================
-- commConfig
-- prefix =comm
---======================================================================

commBaudRate OBJECT-TYPE
   SYNTAX   INTEGER {
 B1200(1),
        B2400(2),
        B4800(3),
        B9600(4),
    B19200(5)
   }
   ACCESS   read-write
   STATUS   current
   DESCRIPTION
          "The UPS communicate baudrate"
    ::= { commConfig 1 }



commDatabits OBJECT-TYPE
   SYNTAX  INTEGER  (8..9)
    
   ACCESS  read-write
   STATUS  current
   DESCRIPTION 
          "The UPS communicate data bits"
   ::= { commConfig 2 }


commStopbits OBJECT-TYPE
   SYNTAX INTEGER (1..2)
   ACCESS read-write
   STATUS current
   DESCRIPTION 
         "The UPS communicate stop bits "
   
  ::= { commConfig 3 }

commParity OBJECT-TYPE
   SYNTAX INTEGER {
       none(0),
       odd(1),
       even(2)
    }
   ACCESS read-write
   STATUS current
   DESCRIPTION
       "The UPS communicate Parity "
  ::= { commConfig 4 }

commTimeout OBJECT-TYPE
   SYNTAX INTEGER (100..1000)
    ACCESS read-write
    STATUS current
    DESCRIPTION
        "The UPS communicate timeout"
    ::= { commConfig 5 }
        
 
--===========================================================================
--
-- upsConfig
--prefix=upsCfg
-- ===========================================================================
 
upsCfgAlarmbypass OBJECT-TYPE
    SYNTAX INTEGER {
         disable(0), 
         enable(1),
  notsupport(2)
         
       }
    ACCESS read-write
    STATUS current
    DESCRIPTION 
       "Setting this object enable /disable alarm bypass mode"

    ::= { upsConfig 1 }
  
upsCfgAlarmbattery OBJECT-TYPE
   SYNTAX INTEGER {
         disable(0),
         enable(1),
  notsupport(2)
    }   
    ACCESS read-write
    STATUS current
    DESCRIPTION
      "Setting this object enable/disable alarm battery mode"

   ::= { upsConfig 2 }

upsCfgAutoReboot OBJECT-TYPE
    SYNTAX     INTEGER {
         disable(0),
         enable(1),
  notsupport(2)
    }
    ACCESS read-write
    STATUS     current
    DESCRIPTION
            "Setting this object enable/disable auto reboot"
    ::= { upsConfig 3 }


upsCfgBypasswhenupsoff OBJECT-TYPE
   SYNTAX INTEGER {
      disable(0),
      enable(1),
      notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION 
      "Setting this object start/stop bypass when ups off"
   ::= { upsConfig 4 }


upsCfgBatterDDP OBJECT-TYPE
   SYNTAX INTEGER {
      disable(0),
      enable(1),
  notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
     "Setting this object to enable/disable battery deep-discharge protection"
   ::= { upsConfig 5 }



   
upsCfgConvertermode OBJECT-TYPE 
   SYNTAX INTEGER {
      disable(0),
      enable(1),
  notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
       "Setting this object to enable/disable converter mode "

   ::= { upsConfig 6 }


upsCfgECOmode OBJECT-TYPE
   SYNTAX INTEGER {
     disable(0),
     enable(1),
  notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
     "Setting this object to enable/disable ECO mode"
  ::= { upsConfig 7 }



upsCfgAdvanceECOmode OBJECT-TYPE
   SYNTAX INTEGER {
     disable(0),
     enable(1),
  notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
     "Setting this object to enable/disable advance ECO mode"
  ::= { upsConfig 8 }


upsCfgGreenPowerFunction OBJECT-TYPE
   SYNTAX INTEGER {
     disable(0),
     enable(1),
  notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
     "Setting this object to enable/disable green power function"
  ::= { upsConfig 9 }

 


upsCfgBatteryOSC OBJECT-TYPE
   SYNTAX INTEGER {
      disable(0),
      enable(1),
  notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
       "Setting this object to enable/disable battery open status check"
   ::= { upsConfig 10 }


upsCfgAllowShort3times OBJECT-TYPE
   SYNTAX INTEGER {
      disable(0),
      enable(1),
  notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
       "Setting this object to enable/disable short 3 times"
   ::= { upsConfig 11 }



upsCfgColdstart OBJECT-TYPE
   SYNTAX INTEGER {
       disable(0),
      enable(1),
  notsupport(2)
       
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Setting this object to cold start ups"
  ::= { upsConfig  12 }


upsCfgBypassNotAllowed OBJECT-TYPE
   SYNTAX INTEGER {
         disable(0),
      enable(1),
  notsupport(2)
       
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Setting this object to enable/disable bypass mode"
  ::= { upsConfig  13 }


upsCfgBatterylowprotect OBJECT-TYPE
  SYNTAX INTEGER {
         disable(0),
      enable(1),
  notsupport(2)
       
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Setting this object to enable/disable battery low protect"
  ::= { upsConfig  14 }



upsCfgP1progoutletcontrol OBJECT-TYPE 
  SYNTAX INTEGER {
     disable(0),
     enable(1),
  notsupport(2)
  }
  ACCESS read-write
  STATUS current
  DESCRIPTION 
     "Setting this object to enable/disable p1 programmable outlet control (battery mode)"
  ::= { upsConfig 15 }



upsCfgP2progoutletcontrol OBJECT-TYPE 
  SYNTAX INTEGER {
     disable(0),
     enable(1),
  notsupport(2)
  }
  ACCESS read-write
  STATUS current
  DESCRIPTION 
     "Setting this object to enable/disable p2 programmable outlet control (battery mode)"
  ::= { upsConfig 16 }


upsCfgInverterShortClear OBJECT-TYPE 
  SYNTAX INTEGER {
     disable(0),
     enable(1),
  notsupport(2)
  }
  ACCESS read-write
  STATUS current
  DESCRIPTION 
     "Setting this object to enable/disable Inverter short clear function"
  ::= { upsConfig 17 }




upsCfgSitefaildetection OBJECT-TYPE
   SYNTAX INTEGER {
     disable(0),
     enable(1),
  notsupport(2)
  }
  ACCESS read-write
  STATUS current
  DESCRIPTION
     "Setting this object to enable/disable site fail detection"
  ::= { upsConfig 18 }



upsCfgBatNumInParallel OBJECT-TYPE 
   SYNTAX INTEGER (1..99)
   ACCESS read-write
   STATUS current
   DESCRIPTION 
      "Battery numbers in parallel (battery numbers setting)"
   ::= { upsConfig 19 }
   

upsCfgBatNumInSeries OBJECT-TYPE 
   SYNTAX INTEGER (1..20)
   ACCESS read-write
   STATUS current
   DESCRIPTION 
      "Battery numbers in series (battery numbers setting)"
   ::= { upsConfig 20 }
   


upsCfgBypassmaxvoltage OBJECT-TYPE
   SYNTAX INTEGER (1760..2760)
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Bypass mode max voltage"

   ::= { upsConfig 21 }


upsCfgBypassminvoltage OBJECT-TYPE
   SYNTAX INTEGER (1760..2640)
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Bypass mode min voltage"
   ::= { upsConfig 22 }


upsCfgBypassmaxfrequency OBJECT-TYPE
   SYNTAX INTEGER (510..700) -- ( 510..600 ,610..700)
   UNITS      "0.1 Hertz"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Bypass mode max frequency ,for 50 HZ (510..600) for 60HZ (610..700)"
   ::= { upsConfig 23 }



upsCfgBypassminfrequency OBJECT-TYPE
   SYNTAX INTEGER (400..590) --(400..490,500..590)
   UNITS      "0.1 Hertz"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Bypass mode min frequency, for 50HZ (400..490) for 60Hz (500..590)"
   ::= { upsConfig 24 }



upsCfgECOmaxvoltage OBJECT-TYPE
   SYNTAX INTEGER (10..3000)
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "ECO mode max voltage"

   ::= { upsConfig 25 }

upsCfgECOminvoltage OBJECT-TYPE
   SYNTAX INTEGER (10..3000)
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "ECO mode min voltage"
   ::= { upsConfig 26 }


upsCfgFreeRunMaxFrequency OBJECT-TYPE
   SYNTAX INTEGER (400..700)
   UNITS      "0.1 Hertz "
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Free run mode max frequency"
   ::= { upsConfig 27 }



upsCfgFreeRunMinFrequency OBJECT-TYPE
   SYNTAX INTEGER (400..700)
   UNITS      "0.1 Hertz "
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "Free run mode min frequency"
   ::= { upsConfig 28 }




upsCfgEPOStatus OBJECT-TYPE
   SYNTAX INTEGER {
     disable(0),
     enable(1)
  }
  ACCESS read-only
  STATUS current
  DESCRIPTION 
     "Get EPO status,configured by mamual"
  ::= { upsConfig 29 }


 
upsCfgQSK1Status OBJECT-TYPE
   SYNTAX INTEGER {
     disable(0),
     enable(1)
  }
  ACCESS read-only
  STATUS current
  DESCRIPTION 
     "Get QSK 1 status"
  ::= { upsConfig 30 }

upsCfgQSK2Status OBJECT-TYPE
   SYNTAX INTEGER {
     disable(0),
     enable(1)
  }
  ACCESS read-only
  STATUS current
  DESCRIPTION 
     "Get QSK 2 status"
  ::= { upsConfig 31 }

upsCfgQSKT1Delaytime OBJECT-TYPE
   SYNTAX INTEGER (0..999)
   UNITS      "minutes "
   ACCESS read-only
   STATUS current
   DESCRIPTION 
     "Get QSKT 1 time delay"
  ::= { upsConfig 32 }

upsCfgQSKT2Delaytime OBJECT-TYPE
   SYNTAX INTEGER (0..999)
   UNITS      "minutes "
   ACCESS read-only
   STATUS current
   DESCRIPTION 
     "Get QSKT 2 time delay"
  ::= { upsConfig 33 }

upsCfgConstantPhaseAngle OBJECT-TYPE
    SYNTAX INTEGER {
         disable(0),
         enable(1) 
     }
     ACCESS read-write
     STATUS current
     DESCRIPTION
      "setting this object to Enable/disable Constant Phase Angle function"
    ::= { upsConfig  34 }

---PE/PD q

upsCfgInPhaseAngle OBJECT-TYPE
   SYNTAX   INTEGER {
        Angle000(0),
        Angle120(120),
        Angle180(180),
        Angle240(240)
   }
   ACCESS   read-only
   STATUS   current
   DESCRIPTION
          "Get input phase angle"
    ::= { upsConfig 35 }

---QPD

upsCfgOutPhaseAngle OBJECT-TYPE
   SYNTAX   INTEGER {
        Angle000(0),
        Angle120(120),
        Angle180(180),
        Angle240(240)
   }
   ACCESS   read-write
   STATUS   current
   DESCRIPTION
          "Set output phase angle"
    ::= { upsConfig 36 }

---QPD PPD<NNN>

upsCfgLimiRunOnBatMode OBJECT-TYPE
      SYNTAX INTEGER {
         disable(0),
         enable(1),
  notsupport(2)
   }
   ACCESS read-write
   STATUS current
   DESCRIPTION
          "Enable/disable limited runtime on battery mode"
    ::= { upsConfig 37 }


upsCfgChargingCurrent OBJECT-TYPE
    SYNTAX     INTEGER
    UNITS      "0.1 Amp DC"
    ACCESS read-only
    STATUS     current
    DESCRIPTION
            "Set charging current to battery ."
    ::= { upsConfig 38 }

upsCfgBatSeftCheckVolt OBJECT-TYPE
   SYNTAX INTEGER (2400..2800)
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "BatTest until battery voltage lower than <nnn>"
    ::= { upsConfig 39 }

upsCfgOverChargVolt OBJECT-TYPE
   SYNTAX INTEGER (130..143)
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "set over charging voltage to per battery"
    ::= { upsConfig 40 }

upsCfgBattUnderVolt OBJECT-TYPE
   SYNTAX INTEGER (2000..2400)
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "set  battery under voltage of setting value.value is a number ranging from 200V to 240V"
    ::= { upsConfig 41 }

upsCfgBattLowVolt OBJECT-TYPE
   SYNTAX INTEGER
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "set battery low voltage of setting value.it is 10 to 40V high than battery under voltage.
       it is 10 to 40V high than battery under voltage.default 20. 
         it means that the battery low point is battery under add 20.
         for example, if the battery under voltage is 210V, the battry low point voltage is 230V.
    "
    ::= { upsConfig 42 }

upsCfgIn1VoltHLoss OBJECT-TYPE
   SYNTAX INTEGER
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "set input1 voltage high loss point."
    ::= { upsConfig 43 }

upsCfgIn1VoltLLoss OBJECT-TYPE
   SYNTAX INTEGER
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "set input1 voltage low loss point."
    ::= { upsConfig 44 }

upsCfgIn2VoltHLoss OBJECT-TYPE
   SYNTAX INTEGER
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "set input2 voltage high loss point."
    ::= { upsConfig 45 }

upsCfgIn2VoltLLoss OBJECT-TYPE
   SYNTAX INTEGER
   UNITS      "0.1 Volts"
   ACCESS read-write
   STATUS current
   DESCRIPTION
      "set input2 voltage low loss point."
    ::= { upsConfig 46 }

upsCfgBatteryTurnOn OBJECT-TYPE
      SYNTAX INTEGER {
         disable(0),
         enable(1),
  notsupport(2)
      }
      ACCESS read-write
      STATUS current
      DESCRIPTION
          "Enable/disable battery turn on."
      ::= { upsConfig 47 }

-- ===========================================================================
-- upsTraps
-- prefix = upsTraps
-- Traps group
-- ===========================================================================

   -- This section defines the well-known notifications sent by
   -- UPS agents.
     
   -- this traps use one share trap-node for send traps ,the trap-node vlaue between 1 and 127.
   -- the share trap-node name is trapleafnodev1v2;

-- if failure or warning  occur ,traps send immediately , if question not resolved,agent will resend  every 4 seconds.
-- info only send once 
   
trapleafnodev103 OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (16..16))
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The share trap-node for send all traps,snmpcard V1-03 and later use this trap-node
  char trap[16];
  trap[0]: trap[0]=1,fault trap ; trap[0]=0,warn trap"
    ::= { upsTraps 998 }

trapleafnodev1v2 OBJECT-TYPE
    SYNTAX INTEGER (0..255)
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
        "The share trap-node for send all traps"
    ::= { upsTraps 999 }


cmpACFailure TRAP-TYPE
     ENTERPRISE upsTraps
     DESCRIPTION
          "AC failure"
    ::= 1

cmpFanFailure TRAP-TYPE
     ENTERPRISE upsTraps
     DESCRIPTION
          "Fan failure"
    ::= 2

cmpUPSFailure TRAP-TYPE
     ENTERPRISE upsTraps
     DESCRIPTION
          "UPS failure"
    ::= 3    

cmpChargerFailure TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "Charger failure"
        ::= 4

cmpOverloadFailure TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "Overload failure"
        ::= 5   

cmpOvertempFailure       TRAP-TYPE
        ENTERPRISE      upsTraps
        DESCRIPTION
                "Over temperature fault."
        ::= 6

cmpInvertershortcircuited  TRAP-TYPE
        ENTERPRISE      upsTraps
        DESCRIPTION
                "Inverter short-circuited"
        ::= 7

cmpbatteryfusebeingoc TRAP-TYPE
        ENTERPRISE      upsTraps
        DESCRIPTION
                "Battery fuse being open-dcircuited failure"
        ::= 8

     

cmpLowbattery  TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "The UPS has returned from a low battery
                 condition."
        ::= 9

cmpSysgotoshutdown TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "System is going to shutdown"
        ::= 10


cmpSitefault TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "Site fault"
        ::= 11      


cmpPhasesequenceincorrect TRAP-TYPE
        ENTERPRISE      upsTraps
        DESCRIPTION
                "Phase sequence incorrect"
        ::= 12

cmpPhasesequenceincorrectbypass TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "Phase sequence incorrect in bypass"
        ::= 13

cmpFanalarm TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "Fan alarm."
        ::= 14


cmpEPOenabled TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
             "EPO enabled"
    ::= 15

cmpUnabletotrunonUPS TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Unalbe to turn on UPS"
   ::= 16

cmpOvertemperaturealarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Over temperature alarm"
   ::= 17

cmpInputfrequnstablebypass TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Input frequency unstable in bypass"
   ::= 18

   
cmpChargeralarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Charger alarm"
   ::= 19
   

cmpL1inputfusenotwork TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L1 input fuse not working"
   ::= 20

cmpNeutralnotConnected  TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Neutral not connected"
   ::= 21   

cmpL2inputfusenotwork TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L2 input fuse not working"
   ::= 22

cmpL3inputfusenotwork TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L3 input fuse not working"
   ::= 23
   

cmpPositivePFCabnormalL1 TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Positive PFC abnormal in L1"
   ::= 24


cmpNegativePFCabnormalL1 TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Negative PFC abnormal in L1"
   ::= 25


cmpPositivePFCabnormalL2 TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Positive PFC abnormal in L2"
   ::= 26

cmpNegativePFCabnormalL2 TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Negative PFC abnormal in L2"
   ::= 27

cmpPositivePFCabnormalL3 TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Positive PFC abnormal in L3"
   ::= 28

cmpNegativePFCabnormalL3 TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Negative PFC abnormal in L3"
   ::= 29


cmpBusvoltagenotwds TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Bus voltage not within default setting"
   ::= 30


cmpBusvoltageovermaxvalue TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Bus voltage over maxinum value"
   ::= 31  
   
cmpBusvoltagebelowminvalue TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Bus voltage below mininum value"
   ::= 32  

cmpBusvoltagediffoutofrange TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Bus voltage differences out fo acceptable range"
   ::= 33  

cmpBusvoltageofsloperatetoofast TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Bus voltage of slope rate drops too fast"
   ::= 34  
  
cmpOvercurrentinPFCII TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "WARNING:Over current in PFC input inductor."
   ::= 35  

cmpInvertervoloutofrange TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Inverter voltage not within default setting."
   ::= 36  
 
cmpInvertervolovermaxvalue TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Inverter voltage over maximum value."
   ::= 37    

cmpInvertervolbelowminvalue TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Inverter voltage below minimum value."
   ::= 38   


cmpBatteryoppositelyconnected TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery oppositely connected."
   ::= 39   

cmpL2phaseshortcicuited TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L2Phase inverter short-cicuited."
   ::= 40 

cmpL3phaseshortcicuited TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L3Phase inverter short-cicuited."
   ::= 41 

cmpL1L2invertershortcicuited TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L1L2Inverter short-cicuited."
   ::= 42 

cmpL2L3invertershortcicuited TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L2L3Inverter short-cicuited."
   ::= 43

cmpL3L1invertershortcicuited TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L3L1Inverter short-cicuited."
   ::= 44
 

cmpL1negativepoweroutofrange TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L1 inverter negative powere out of acceptable range."
   ::= 45

cmpL2negativepoweroutofrange TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L2 inverter negative powere out of acceptable range."
   ::= 46

cmpL3negativepoweroutofrange TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "L3 inverter negative powere out of acceptable range."
   ::= 47

cmpBatterySCRshortcircuited TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery SCR short-circuited."
   ::= 48

cmpLineSCRshortcircuited TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Line SCR short-circuited."
   ::= 49

cmpInverterrelayopenfault TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Inverter relay open fault."
   ::= 50 

cmpInverterrelayshortcircuited TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Inverter relay short-circuited."
   ::= 51

cmpInoutwiresoppositelyconnected TRAP-TYPE
       ENTERPRISE upsTraps
    DESCRIPTION
          "Input and output wires oppositely connected."
   ::= 52 
   
cmpabnormalcanbuscommunication TRAP-TYPE
        ENTERPRISE upsTraps
    DESCRIPTION
          "Abnormal in CAN-bus communication."
   ::= 53

cmpcommfailurebcupsboard TRAP-TYPE
        ENTERPRISE upsTraps
    DESCRIPTION
          "Communication failure between cpus in control board.Or DSP and MCU communication error"
   ::= 54

cmpabnormalsyncsignalcircuit TRAP-TYPE
          ENTERPRISE upsTraps
    DESCRIPTION
          "Abnomal in synchronous signal circuit."
   ::= 55
 
cmpabnormalsyncpulsesignalcircuit TRAP-TYPE
          ENTERPRISE upsTraps
    DESCRIPTION
          "Abnomal in synchronous pulse signal circuit."
   ::= 56
   

cmpcurrent3punbalancedetected TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Warning for a three-phase input current unbalance detected."
   ::= 57

cmpbatteryselftestfailure TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery self-test failure."
   ::= 58

cmpintercurrentunbalance TRAP-TYPE
      ENTERPRISE upsTraps
    DESCRIPTION
          "Inverter inter-current unbalance."
   ::= 59

cmpbatterydisconnected TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery disconnected."
   ::= 60
 
cmpabnormalhostsignalcircuit TRAP-TYPE
     ENTERPRISE upsTraps
    DESCRIPTION
          "Abnormal in host signal circuit."
   ::= 61

cmpbatteryovercharged TRAP-TYPE
     ENTERPRISE upsTraps
    DESCRIPTION
          "Bettery overcharged."
   ::= 62

cmpbatteryvoltoohigh TRAP-TYPE
     ENTERPRISE upsTraps
    DESCRIPTION
          "Bettery voltage is too high."
   ::= 63  

cmpbatteryvoltoolow TRAP-TYPE
     ENTERPRISE upsTraps
    DESCRIPTION
          "Bettery voltage is too low."
   ::= 64  

cmpfemaleconnectornotconnwell TRAP-TYPE
     ENTERPRISE upsTraps
    DESCRIPTION
          "Female connector of parallel cable not connected well."
   ::= 65  

cmpmaleconnectornotconnwell TRAP-TYPE
     ENTERPRISE upsTraps
    DESCRIPTION
          "Male connector of parallel cable not connected well."
   ::= 66


cmplockingbypassA3COW30M TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Locking inbypass mode after 3 consecutive overloads within 30 minutes"

   ::= 67


cmpparallelcabledisconnected TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Parallel cable disconnected"

   ::= 68
 
cmpsyncpulsecircuitfault TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Synchronous pulse signal circuit fault"

   ::= 69


cmpsyncsignalcircuitfalt TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Synchronous  signal circuit fault"

   ::= 70

cmphostsignalcircuitfault TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Host signal circuit fault"

   ::= 71 

cmpcanbuscommunicationfault TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Can-bus communication fault"

   ::= 72 

cmplowlosspointforvolinACmode TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Low loss point for voltage in ac mode not consistent in parallel systems"

   ::= 73 

cmphighlosspointforvolinACmode TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "High loss point for voltage in ac mode not consistent in parallel systems"

   ::= 74 

cmplowlosspointforfreqinACmode TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Low loss point for frequency in ac mode not consistent in parallel systems"

   ::= 75 

cmphighlosspointforfreqinACmode TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "High loss point for frequency in ac mode not consistent in parallel systems"

   ::= 76 

cmplowlosspointforvolinbypassmode TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Low loss point for voltage in bypass mode not consistent in parallel systems"

   ::= 77


cmphighlosspointforvolinbypassmode TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "High loss point for voltage in bypass mode not consistent in parallel systems"

   ::= 78


cmplowlosspointforfreqinbypassmode TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Low loss point for frequency in bypass mode not consistent in parallel systems"

   ::= 79 

cmphighlosspointforfreqinbypassmode TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "High loss point for frequency in bypass mode not consistent in parallel systems"

   ::= 80

cmploadunbalanced TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Load unbalanced"

   ::= 81    


cmpoverloadalarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Overload alarm"

   ::= 82    


cmpparallelnotconnectedwell TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Parallel cable not connected well"

   ::= 83  

cmpcommunicationlost TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Communication lost"
   ::= 84  


cmpbatteryconnnotsonsistent TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery connection not consistent in parallel systems"
   ::= 85  


cmpconverternotconsisstent   TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Converter setting not consistent in parallel systems"
   ::= 86  

cmpbypassnotallownotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Bypass not allowed setting not consistent in parallel systems"
   ::= 87  


cmpACconnnotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "AC connection not consistent in parallel systems"
   ::= 88

cmpinput3pcurrentunbalance TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Warning for three-phase ac input current unbalance"
   ::= 89

cmpbypassconnnotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Bypass connection not consistent in parallel systems"
   ::= 90

cmpbatteryprotectionnotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Battery protection setting not consistent in parallel systems"
   ::= 91

cmpbatterydetectionnotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Battery detection setting not consistent in parallel systems"
   ::= 92



cmpupsmodeltypesnotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "UPS model types not consistent in parallel systems"
   ::= 93

cmpbypassnotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Bypass setting not consistent in parallel systems"
   ::= 94


cmpcapacitynotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Capacity of upss not consistent in parallel systems"
   ::= 95

cmpautorestartnotconsistent TRAP-TYPE
  ENTERPRISE upsTraps
    DESCRIPTION
          "Auto restart setting not consistent in parallel systems"
   ::= 96


cmpBatteryReplace TRAP-TYPE   ENTERPRISE upsTraps
    DESCRIPTION
          "Battery need to be replace"
   ::= 97


cmpACNormal  TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "AC normal"
   ::= 100

cmpOutputBadAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Output bad alarm"
   ::= 103


cmpBypassBadAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Bypass bad alarm"
   ::= 104


cmpOutputOffAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Output off alarm"
   ::= 105


cmpUPSShutAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "UPS shutdown alarm"
   ::= 106

cmpSystemOffAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "System off alarm"
   ::= 107

cmpFuseFailureAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Fuse failure alarm"
   ::= 108

cmpGenFailureAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "General failure alarm"
   ::= 109

cmpAwaitPowerAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Awaiting power alarm"
   ::= 110

cmpShutPendingAlarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Shutdown pending alarm"
   ::= 111

cmpBatDepleted TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery depleted"
   ::= 112


cmpUnknowStatus TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery unknow status"
   ::= 113

cmpOutputOn TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Output on"
   ::= 114

cmpTurntobypass TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Ups turn to bypass mode"
   ::= 115

cmpTurntobattery TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Ups turn to battery mode"
   ::= 116

cmpOutBooster TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Turn to booster"
   ::= 117


cmpOutReducer TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Turn to reducer"
   ::= 118

cmpOutBattest TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Turn to battery test mode"
   ::= 119


cmpOtherSource TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Other source"
   ::= 120

cmpBatfailure TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery failure"
   ::= 121


cmpBatTestDonePassed TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery test passed"
   ::= 122

cmpBatTestDoneWarning TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery test done warning "
   ::= 123


cmpBatTestDoneAborted TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery test done Aborted"
   ::= 124

cmpBatteryNormal TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery normal"
   ::= 125

cmpBatteryDischarging TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Battery Discharging  "
   ::= 126

cmpP1cutoffprealarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "P1 cut off pre-alarm "
   ::= 127

cmpInputPhaseError TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Warning for input phase error for LV 6-10K UPS"
   ::= 128
cmpMaintainSwitchOpenalarm TRAP-TYPE
    ENTERPRISE upsTraps
    DESCRIPTION
          "Warning for maintain switch open"
   ::= 129

cmpEMDChAbnormal1 TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "EMD Channels 1 Abnormal"
        ::= 130
cmpEMDChAbnormal2 TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "EMD Channels 2 Abnormal"
        ::= 131
cmpEMDChAbnormal3 TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "EMD Channels 3 Abnormal"
        ::= 132
cmpEMDChAbnormal4 TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "EMD Channels 4 Abnormal"
        ::= 133
cmpEMDChAbnormal5 TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "EMD Channels 5 Abnormal: smoke alarm"
        ::= 134
cmpEMDChAbnormal6 TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "EMD Channels 6 Abnormal"
        ::= 135
cmpEMDChAbnormal7 TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "EMD Channels 7 Abnormal"
        ::= 136
cmpEMDChAbnormal8 TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
                "EMD Channels 8 Abnormal"
        ::= 137
--===============================================================================
--extend          
--===============================================================================

extendWorkTemperature OBJECT-TYPE
  SYNTAX INTEGER (-2200..2200)
  UNITS     "degrees 0.1 Centigrade"
  ACCESS read-only
  STATUS current
  DESCRIPTION
    "The temperature of work environment"
  ::= { extend 1 }

extendWorkhumidity OBJECT-TYPE
  SYNTAX INTEGER (0..100)
  UNITS "percent"
  ACCESS read-only
  STATUS current
  DESCRIPTION
    "The humidity of work environment"
  ::= { extend 2 }


extendSmokeScope OBJECT-TYPE
  SYNTAX INTEGER (0..1000000)
  UNITS "%/FOOT"
  ACCESS read-only
  STATUS current
  DESCRIPTION
    "The smokeScope of work environment"
  ::= { extend 3 }


extendEMDAlarm1 OBJECT-TYPE
  SYNTAX INTEGER {
     on(1),
     off(0)
   }
  ACCESS read-only
  STATUS current
  DESCRIPTION
    "Environment  detector alarm 1"
  ::= { extend 4 } 

extendEMDAlarm2 OBJECT-TYPE
  SYNTAX INTEGER {
     on(1),
     off(0)
   }
  ACCESS read-only
  STATUS current
  DESCRIPTION
    "Environment  detector alarm 2"
  ::= { extend 5 } 


extendEMDAlarm3 OBJECT-TYPE
  SYNTAX INTEGER {
     on(1),
     off(0)
   }
  ACCESS read-only
  STATUS current
  DESCRIPTION
    "Environment  detector alarm 3"
  ::= { extend 6 } 

extendEMDAlarm4 OBJECT-TYPE
  SYNTAX INTEGER {
     on(1),
     off(0)
   }
  ACCESS read-only
  STATUS current
  DESCRIPTION
    "Environment  detector alarm 4"
  ::= { extend 7 } 

END