-- powertek
-- MIB for 1phase Products 
--
-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610)
-- product(1) pdu(4) sps(4)
-- ==============================================================================================
---
---     Revision History
---
---     v0.10   14-Feb-2014     ChainLiu
---     v0.11   11-Mar-2014     JimmyYang
---     v0.12   01-Sep-2014     ChainLiu/
---     v0.13   24-Nov-2014     ChainLiu 
---     v0.14   12-Aug-2015     ChainLiu 
-- ==============================================================================================

SPSv1-MIB DEFINITIONS ::= BEGIN

IMPORTS
  enterprises
    FROM RFC1155-SMI
  OBJECT-TYPE
    FROM RFC-1212
  DisplayString
    FROM RFC1213-MIB
  TRAP-TYPE
    FROM RFC-1215;

powertek             OBJECT IDENTIFIER ::= { enterprises 42610 }
product              OBJECT IDENTIFIER ::= { powertek 1 }
pdu                  OBJECT IDENTIFIER ::= { product 4 }
sps                  OBJECT IDENTIFIER ::= { pdu 4 }
pduObjects           OBJECT IDENTIFIER ::= { sps 1 }
pduTraps             OBJECT IDENTIFIER ::= { sps 2 }

pduIdent             OBJECT IDENTIFIER ::= { pduObjects 1 }
pduNetwork           OBJECT IDENTIFIER ::= { pduObjects 2 }
pduSystem            OBJECT IDENTIFIER ::= { pduObjects 3 }
pduSNMP              OBJECT IDENTIFIER ::= { pduObjects 4 }
pduEmail             OBJECT IDENTIFIER ::= { pduObjects 5 }
pduPwrMonitoring     OBJECT IDENTIFIER ::= { pduObjects 6 }
pduEnvMonitoring     OBJECT IDENTIFIER ::= { pduObjects 7 }

-- ===========================================================================
--
-- pduIdent
--
--  pdu Identification Group
--
-- ===========================================================================
pduIdentAgentSoftwareVersion OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..63))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
               "The firmware version of the device."
      ::= { pduIdent 1 }

pduIdentSerialNumber OBJECT-TYPE
      SYNTAX DisplayString (SIZE(0..31))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "A Model of this device."
      ::= { pduIdent 2 }


pduNetworkTcpip    OBJECT IDENTIFIER ::= { pduNetwork 1 }
-- ===========================================================================
--
-- pduNetworkTcpip
--
--  Network Configuration Group of the device.
--
-- ===========================================================================

pduNetworkTcpipDhcpControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable DHCP protocol"
        ::= { pduNetworkTcpip 1 }

pduNetworkTcpipIpv4    OBJECT IDENTIFIER ::= { pduNetworkTcpip 2 }
-- ===========================================================================
--
-- pduNetworkTcpipIpv4
--
--  Ip address Configuration Group of the device.
--
-- ===========================================================================
pduNetworkTcpipIpv4Address OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The ip address that NMS can identify the managed device."
        ::= { pduNetworkTcpipIpv4 1}

pduNetworkTcpipIpv4Gateway OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The default gateway that allow device managed through routers."
        ::= { pduNetworkTcpipIpv4 2}

pduNetworkTcpipIpv4Subnet OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Internet address subnet mask"
        ::= { pduNetworkTcpipIpv4 3}

pduNetworkTcpipIpv4PrimaryDNS OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Internet address of Primary DNS Server"
        ::= { pduNetworkTcpipIpv4 4}

pduNetworkTcpipIpv4SecondaryDNS OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Internet address of Secondary DNS"
        ::= { pduNetworkTcpipIpv4 5}

pduNetworkTcpipIpv6    OBJECT IDENTIFIER ::= { pduNetworkTcpip 3 }
-- ===========================================================================
--
-- pduNetworkTcpipIpv6
--
--  Ip address Configuration Group of the device.
--
-- ===========================================================================
pduNetworkTcpipIpv6Control OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable IPv6 protocol"
        ::= { pduNetworkTcpipIpv6 1 }

pduNetworkTcpipIpv6AutoConfig OBJECT-TYPE
        SYNTAX  INTEGER {
                auto(1),
                manual(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "IPv6 Auto-config or Maual setting"
        ::= { pduNetworkTcpipIpv6 2 }

pduNetworkTcpipIpv6Address OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..63))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The ipv6 address that NMS can identify the managed device."
        ::= { pduNetworkTcpipIpv6 3}

pduNetworkTcpipIpv6Prefix OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The prefix length for ipv6 address."
        ::= { pduNetworkTcpipIpv6 4}

pduNetworkTcpipIpv6Router OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..63))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The default gateway that allow device managed through routers."
        ::= { pduNetworkTcpipIpv6 5}

pduNetworkTcpipIpv6PrimaryDNS OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..63))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Internet address of Primary DNS Server"
        ::= { pduNetworkTcpipIpv6 6}

pduNetworkTcpipIpv6SecondaryDNS OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..63))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Internet address of Secondary DNS"
        ::= { pduNetworkTcpipIpv6 7}



pduNetworkSecurity    OBJECT IDENTIFIER ::= { pduNetwork 2 }
-- ===========================================================================
--
-- pduNetworkSecurity
--
--  Network Security Group of the device.
--
-- ===========================================================================
pduNetworkSecurityControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable Network Access Protection"
        ::= { pduNetworkSecurity 1 }

pduNetworkSecuritySsh    OBJECT IDENTIFIER ::= { pduNetworkSecurity 2 }
-- ===========================================================================
--
-- pduNetworkSecuritySsh
--
--  SSH Security Group Group of the device.
--
-- ===========================================================================
pduNetworkSecuritySshControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable SSH Access Protection"
        ::= { pduNetworkSecuritySsh 1 }

pduNetworkSecuritySshInterval OBJECT-TYPE
        SYNTAX  INTEGER {
                oneMinute(1),
                fiveMinutes(2),
                tenMinutes(3),
                thirtyMinutes(4)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Detecting Interval of SSH Access Protection"
        ::= { pduNetworkSecuritySsh 2 }

pduNetworkSecuritySshFailTimes OBJECT-TYPE
        SYNTAX  INTEGER {
                five(1),
                ten(2),
                twenty(3),
                thirty(4),
                hundred(5)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Unsuccessful attempts of SSH Access Protection"
        ::= { pduNetworkSecuritySsh 3 }

pduNetworkSecuritySshBlock OBJECT-TYPE
        SYNTAX  INTEGER {
                fiveMinutes(1),
                thirtyMinutes(2),
                oneHour(3),
                oneDay(4)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Block Time of SSH Access Protection"
        ::= { pduNetworkSecuritySsh 4 }

pduNetworkSecuritySnmp    OBJECT IDENTIFIER ::= { pduNetworkSecurity 3 }
-- ===========================================================================
--
-- pduNetworkSecuritySnmp
--
--  SNMP Security Group Group of the device.
--
-- ===========================================================================
pduNetworkSecuritySnmpControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable SNMP Access Protection"
        ::= { pduNetworkSecuritySnmp 1 }

pduNetworkSecuritySnmpInterval OBJECT-TYPE
        SYNTAX  INTEGER {
                oneMinute(1),
                fiveMinutes(2),
                tenMinutes(3),
                thirtyMinutes(4)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Detecting Interval of SNMP Access Protection"
        ::= { pduNetworkSecuritySnmp 2 }

pduNetworkSecuritySnmpFailTimes OBJECT-TYPE
        SYNTAX  INTEGER {
                five(1),
                ten(2),
                twenty(3),
                thirty(4),
                hundred(5)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Unsuccessful attempts of SNMP Access Protection"
        ::= { pduNetworkSecuritySnmp 3 }

pduNetworkSecuritySnmpBlock OBJECT-TYPE
        SYNTAX  INTEGER {
                fiveMinutes(1),
                thirtyMinutes(2),
                oneHour(3),
                oneDay(4)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Block Time of SNMP Access Protection"
        ::= { pduNetworkSecuritySnmp 4 }

pduNetworkSecurityHttp    OBJECT IDENTIFIER ::= { pduNetworkSecurity 4 }
-- ===========================================================================
--
-- pduNetworkSecurityHttp
--
--  HTTP Security Group Group of the device.
--
-- ===========================================================================
pduNetworkSecurityHttpControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable HTTP Access Protection"
        ::= { pduNetworkSecurityHttp 1 }

pduNetworkSecurityHttpInterval OBJECT-TYPE
        SYNTAX  INTEGER {
                oneMinute(1),
                fiveMinutes(2),
                tenMinutes(3),
                thirtyMinutes(4)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Detecting Interval of HTTP Access Protection"
        ::= { pduNetworkSecurityHttp 2 }

pduNetworkSecurityHttpFailTimes OBJECT-TYPE
        SYNTAX  INTEGER {
                five(1),
                ten(2),
                twenty(3),
                thirty(4),
                hundred(5)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Unsuccessful attempts of HTTP Access Protection"
        ::= { pduNetworkSecurityHttp 3 }

pduNetworkSecurityHttpBlock OBJECT-TYPE
        SYNTAX  INTEGER {
                fiveMinutes(1),
                thirtyMinutes(2),
                oneHour(3),
                oneDay(4)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Block Time of HTTP Access Protection"
        ::= { pduNetworkSecurityHttp 4 }


pduNetworkService    OBJECT IDENTIFIER ::= { pduNetwork 3 }
-- ===========================================================================
--
-- pduNetworkService
--
--  Network Service Group of the device.
--
-- ===========================================================================

pduNetworkServiceSsh    OBJECT IDENTIFIER ::= { pduNetworkService 1 }
-- ===========================================================================
--
-- pduNetworkServiceSsh
--
--  SSH Service Group of the device.
--
-- ===========================================================================
pduNetworkServiceSshControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable SSH Server Service"
        ::= { pduNetworkServiceSsh 1 }

pduNetworkServiceSshPort OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Port Number of SSH Server Service"
        ::= { pduNetworkServiceSsh 2 }


pduNetworkServiceSsl    OBJECT IDENTIFIER ::= { pduNetworkService 2 }
-- ===========================================================================
--
-- pduNetworkServiceSsl
--
--  HTTPs Service Group of the device.
--
-- ===========================================================================
pduNetworkServiceSslControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable HTTPs Server Service"
        ::= { pduNetworkServiceSsl 1 }

pduNetworkServiceSslPort OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Port Number of HTTPs Server Service"
        ::= { pduNetworkServiceSsl 2 }

pduNetworkServiceSslForce OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Force use HTTPs Server Service only."
        ::= { pduNetworkServiceSsl 3 }

pduNetworkServicePingControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable to response to PING request."
        ::= { pduNetworkService 3 }


pduNetworkServiceRadius    OBJECT IDENTIFIER ::= { pduNetworkService 4 }
-- ===========================================================================
--
-- pduNetworkServiceRadius
--
--  RADIUS Client Service Group of the device.
--
-- ===========================================================================
pduNetworkServiceRadiusControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable RADIUS Client Service"
        ::= { pduNetworkServiceRadius 1 }

pduNetworkServiceRadiusIp OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..63))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The IP Address of RADIUS Client Service"
        ::= { pduNetworkServiceRadius 2 }

pduNetworkServiceRadiusPort OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Port Number of RADIUS Client Service"
        ::= { pduNetworkServiceRadius 3 }

pduNetworkServiceRadiusSecretKey OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..31))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Secret Key of RADIUS Client Service"
        ::= { pduNetworkServiceRadius 4 }

pduNetworkServiceRadiusTimeout OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Timeout Interval of RADIUS Client Service in seconds"
        ::= { pduNetworkServiceRadius 5 }

pduNetworkServiceRadiusRetry OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Retry Times of RADIUS Client Service"
        ::= { pduNetworkServiceRadius 6 }


-- ===========================================================================
--
-- pduSystem
--
--  System Management Group of the device.
--
-- ===========================================================================
pduSystemName OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..31))
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "The name of system."
       ::= { pduSystem 1 }

pduSystemContact OBJECT-TYPE
      SYNTAX DisplayString (SIZE (0..31))
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION
          "The contact of system."
      ::= { pduSystem 2 }

pduSystemLocation OBJECT-TYPE
      SYNTAX DisplayString (SIZE (0..31))
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION
          "The location of system."
      ::= { pduSystem 3 }

pduSystemLogInterval OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Log Interval of device"
        ::= { pduSystem 4 }

pduSystemWebRefresh OBJECT-TYPE
        SYNTAX INTEGER (3..60)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Web Refresh Interval of device"
        ::= { pduSystem 5 }

pduSystemTime    OBJECT IDENTIFIER ::= { pduSystem 6 }
-- ===========================================================================
--
-- pduSystemTime
--
--  Date/Time Configuration Group of the device.
--
-- ===========================================================================
pduSystemTimeDisplay OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The date/time in agent"
        ::= { pduSystemTime 1 }

pduSystemTimeZone OBJECT-TYPE
        SYNTAX  INTEGER {
                    gMT-1200InternationalDateLineWest(1),
                    gMT-1200Eniwetok-Kwajalein(2),
                    gMT-1100MidwayIsland-Samoa(3),
                    gMT-1000Hawaii(4),
                    gMT-0900Alaska(5),
                    gMT-0800PacificTime-Tijuana(6),
                    gMT-0700Arizona-MountainTime(7),
                    gMT-0700Chihuahua-LaPaz-Mazatlan(8),
                    gMT-0700MountainTime(9),
                    gMT-0600CentralAmerica(10),
                    gMT-0600CentralTime(11),
                    gMT-0600Guadalajara-MexicoCity-Monterrey(12),
                    gMT-0600Saskatchewan(13),
                    gMT-0500Bogota-Lima-Quito(14),
                    gMT-0500EasternTime(15),
                    gMT-0500Indiana(16),
                    gMT-0400AtlanticTime(17),
                    gMT-0400Caracas-LaPaz(18),
                    gMT-0400Santiago(19),
                    gMT-0330Newfoundland(20),
                    gMT-0300Brasilia(21),
                    gMT-0300BuenosAires-Georgetown(22),
                    gMT-0300Greenland(23),
                    gMT-0200Mid-Atlantic(24),
                    gMT-0100Azores(25),
                    gMT-0100CapeVerdeIs(26),
                    gMT-0000Casablanca-Monrovia(27),
                    gMT-0000GreenwichMeanTime-Dublin-Edinburgh-Lisbon-London(28),
                    gMT0100Amsterdam-Berlin-Bern-Rome-Stockholm-Vienna(29),
                    gMT0100Belgrade-Bratislava-Budapest-Ljubljana-Prague(30),
                    gMT0100Brussels-Copenhagen-Madrid-Paris(31),
                    gMT0100Sarajevo-Skopje-Warsaw-Zagreb(32),
                    gMT0100WestCentralAfrica(33),
                    gMT0200Athens-Istanbul-Minsk(34),
                    gMT0200Bucharest(35),
                    gMT0200Cairo(36),
                    gMT0200Harare-Pretoria(37),
                    gMT0200Helsinki-Kyiv-Riga-Sofia-Tallinn-Vilnius(38),
                    gMT0200Jerusalem(39),
                    gMT0300Baghdad(40),
                    gMT0300Kuwait-Riyadh(41),
                    gMT0300Moscow-StPetersburg-Volgograd(42),
                    gMT0300Nairobi(43),
                    gMT0330Tehran(44),
                    gMT0400AbuDhabi-Muscat(45),
                    gMT0400Baku-Tbilisi-Yerevan(46),
                    gMT0430Kabul(47),
                    gMT0500Ekaterinburg(48),
                    gMT0500Islamabad-Karachi-Tashkent(49),
                    gMT0530Bombay-Calcutta(50),
                    gMT0530Chennai-Kolkata-Mumbai-NewDelhi(51),
                    gMT0545Kathmandu(52),
                    gMT0600Almaty-Novosibirsk(53),
                    gMT0600Astana-Dhaka(54),
                    gMT0600SriJayawardenepura(55),
                    gMT0630Rangoon(56),
                    gMT0700Bangkok-Hanoi-Jakarta(57),
                    gMT0700Krasnoyarsk(58),
                    gMT0800Beijing-Chongqing-HongKong-Urumqi(59),
                    gMT0800Irkutsk-UlaanBataar(60),
                    gMT0800KualaLumpur-Singapore(61),
                    gMT0800Perth(62),
                    gMT0800Taipei(63),
                    gMT0900Osaka-Sapporo-Tokyo(64),
                    gMT0900Seoul(65),
                    gMT0900Yakutsk(66),
                    gMT0930Adelaide(67),
                    gMT0930Darwin(68),
                    gMT1000Brisbane(69),
                    gMT1000Canberra-Melbourne-Sydney(70),
                    gMT1000Guam-PortMoresby(71),
                    gMT1000Hobart(72),
                    gMT1000Vladivostok(73),
                    gMT1100Magadan-SolomonIs-NewCaledonia(74),
                    gMT1200Auckland-Wellington(75),
                    gMT1200Fiji-Kamchatka-MarshallIs(76),
                    gMT1300NukuAlofa(77)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Time Zone to use when synchronize with NTP server."
        ::= { pduSystemTime 2 }

pduSystemTimeFormat OBJECT-TYPE
        SYNTAX  INTEGER {
                mmddyyyy(1),
                ddmmyyyy(2),
                yyyymmdd(3)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Date Format"
        ::= { pduSystemTime 3 }

pduSystemTimeSetting OBJECT-TYPE
        SYNTAX  INTEGER {
                twentyFourHrFormat(1),
                twelveHrFormat(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Time Setting"
        ::= { pduSystemTime 4 }

pduSystemTimeDayLightSaving OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the Day Light Saving when synchronize with NTP server."
        ::= { pduSystemTime 5 }

pduSystemTimeManual    OBJECT IDENTIFIER ::= { pduSystemTime 6 }
-- ===========================================================================
--
-- pduSystemTimeManual
--
--  Manual Time Setting Configuration Group of the device.
--
-- ===========================================================================
pduSystemTimeManualDate OBJECT-TYPE
        SYNTAX DisplayString (SIZE (10..10))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The date in agent, format is (dd/mm/yyyy)"
        ::= { pduSystemTimeManual 1 }

pduSystemTimeManualTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (8..8))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time in agent, format is (hh:mm:ss)"
        ::= { pduSystemTimeManual 2 }

pduSystemTimeNtp    OBJECT IDENTIFIER ::= { pduSystemTime 7 }
-- ===========================================================================
--
-- pduSystemTimeNtp
--
--  NTP Configuration Group of the device.
--
-- ===========================================================================
pduSystemTimeNtpControl OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable the agent to synchronize date/time with NTP server."
        ::= { pduSystemTimeNtp 1 }

pduSystemTimeNtpServer OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..63))
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "The ip address of NTP server."
       ::= { pduSystemTimeNtp 2 }

pduSystemTimeNtpSyncInterval OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "The Sync Interval with NTP server."
       ::= { pduSystemTimeNtp 3 }

pduSystemTimeNtpSyncUnit OBJECT-TYPE
        SYNTAX  INTEGER {
                day(1),
                month(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Unit of Sync Interval"
        ::= { pduSystemTimeNtp 4 }

pduSystemResetToDefault OBJECT-TYPE
        SYNTAX  INTEGER {
                nothing(1),
                reset(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Reset the parameter of PDU to default."
        ::= { pduSystem 7 }

pduSystemReboot OBJECT-TYPE
        SYNTAX  INTEGER {
                nothing(1),
                reboot(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Reboot the system of PDU."
        ::= { pduSystem 8 }

-- ===========================================================================
--
-- pduSNMP
--
--  SNMP Configuration Group of the device.
--
-- ===========================================================================
pduSnmpControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable SNMP protocol."
        ::= { pduSNMP 1 }
        
pduSnmpPort OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The UDP port for SNMP."
        ::= { pduSNMP 2}

pduSnmpVersion OBJECT-TYPE
        SYNTAX  INTEGER {
                v1(1),
                v2(2),
                v3(3)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Set SNMP version."
        ::= { pduSNMP 3 }

pduSnmpTrapsReceiversTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PduSnmpTrapsReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of managers to send traps to.  The number of
                 entries is given by the value of pduSnmpNumTrapReceivers"
        ::= { pduSNMP 4}

pduSnmpTrapsReceiversEntry OBJECT-TYPE
        SYNTAX PduSnmpTrapsReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The managers to send traps to."
        INDEX  { trapsIndex}
        ::= { pduSnmpTrapsReceiversTable 1 }

PduSnmpTrapsReceiversEntry ::=
        SEQUENCE {
                trapsIndex
                        INTEGER,
                trapsReceiverAddr
                        DisplayString,
                receiverEventLevel
                        INTEGER,
                receiverSnmpVer
                        INTEGER,
                receiverDescription
                         DisplayString
        }

trapsIndex OBJECT-TYPE
        SYNTAX INTEGER (0..15)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a trap receiver entry."
        ::= { pduSnmpTrapsReceiversEntry 1 }

trapsReceiverAddr OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..31))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The IP address of the manager to send a trap to."
        ::= { pduSnmpTrapsReceiversEntry 2 }

receiverEventLevel OBJECT-TYPE
        SYNTAX  INTEGER {
                critical(1),
                warning(2),
                informational(3)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The severity level of traps to be received by this manager."
        ::= { pduSnmpTrapsReceiversEntry 3 }

receiverSnmpVer OBJECT-TYPE
        SYNTAX  INTEGER {
                v1(1),
                v2(2),
                v3(3)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The SNMP Trap version of trap receivers."
        ::= { pduSnmpTrapsReceiversEntry 4 }

receiverDescription OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..63))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Description of trap receivers"
        ::= { pduSnmpTrapsReceiversEntry 5 }


-- ===========================================================================
--
-- pduEmail
--
--  Email Configuration Group of the device.
--
-- ===========================================================================
pduEmailServer OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..63))
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "The address of Email server."
       ::= { pduEmail 1 }

pduEmailPort OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The UDP port for Email Server."
        ::= { pduEmail 2}

pduEmailSenderEmail OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..63))
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "The sender's Email address"
       ::= { pduEmail 3 }

pduEmailPrefix OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..31))
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "The prefix string of mail subject"
       ::= { pduEmail 4 }

pduEmailAuthControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable SMTP Authentication."
        ::= { pduEmail 5 }

pduEmailAuthUsername OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..31))
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "The user name of SMTP Authentication"
       ::= { pduEmail 6 }

pduEmailAuthPassword OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..31))
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "The password of SMTP Authentication"
       ::= { pduEmail 7 }

pduEmailReceiversTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PduEmailReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of managers to send email notification to."
        ::= { pduEmail 8}

pduEmailReceiversEntry OBJECT-TYPE
        SYNTAX PduEmailReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The managers to send email notification to."
        INDEX  { mailRecvIndex}
        ::= { pduEmailReceiversTable 1 }

PduEmailReceiversEntry ::=
        SEQUENCE {
                mailRecvIndex
                        INTEGER,
                mailRecvReceiverAddr
                        DisplayString,
                mailRecvEmailType
                        INTEGER,
                mailRecvEventLevel
                        INTEGER,
                mailRecvDescription
                         DisplayString
        }

mailRecvIndex OBJECT-TYPE
        SYNTAX INTEGER (0..15)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a email notification receiver entry."
        ::= { pduEmailReceiversEntry 1 }

mailRecvReceiverAddr OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..63))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Email address of the manager to send a email notification to."
        ::= { pduEmailReceiversEntry 2 }

mailRecvEmailType OBJECT-TYPE
        SYNTAX  INTEGER {
                none(1),
                events(2),
                status(3),
                both(4)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Email Type of email notification receivers."
        ::= { pduEmailReceiversEntry 3 }

mailRecvEventLevel OBJECT-TYPE
        SYNTAX  INTEGER {
                critical(1),
                warning(2),
                informational(3)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The severity level of email notification to be received by this manager."
        ::= { pduEmailReceiversEntry 4 }

mailRecvDescription OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..63))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Description of email notification receivers"
        ::= { pduEmailReceiversEntry 5 }

pduPwrMonitoringInlet      OBJECT IDENTIFIER ::= { pduPwrMonitoring 1 }
-- ===========================================================================
--
-- pduPwrMonitoringInlet
--
--  Inlet Management Group of the device.
--
-- ===========================================================================
pduPwrMonitoringInletNum OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of Inlet."
        ::= { pduPwrMonitoringInlet 1}

-- ===========================================================================
--
-- pduPwrMonitoringInletStatusTable
--
--  Inlet Status Group
--
-- ===========================================================================
pduPwrMonitoringInletStatusTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringInletStatusEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of Inlet."
        ::= { pduPwrMonitoringInlet 2}

pduPwrMonitoringInletStatusEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringInletStatusEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of Inlet."
        INDEX  { inletIndex}
        ::= { pduPwrMonitoringInletStatusTable 1 }

PduPwrMonitoringInletStatusEntry ::=
        SEQUENCE {
                inletIndex
                        INTEGER,
                inletPowerAll
                        INTEGER,
                inletResetFrom
                        DisplayString,
                inletEnergy
                        INTEGER,
                inletStatus
                        INTEGER,
                inletCurrPhase1
                        INTEGER,
                inletCurrPhase2
                        INTEGER,
                inletCurrPhase3
                        INTEGER,
                inletVoltPhase1
                        INTEGER,
                inletVoltPhase2
                        INTEGER,
                inletVoltPhase3
                        INTEGER,
                inletPwrFactorPhase1
                        INTEGER,
                inletPwrFactorPhase2
                        INTEGER,
                inletPwrFactorPhase3
                        INTEGER,
                inletPowerPhase1
                        INTEGER,
                inletPowerPhase2
                        INTEGER,
                inletPowerPhase3
                        INTEGER,
                inletStatusPhase1
                        INTEGER,
                inletStatusPhase2
                        INTEGER,
                inletStatusPhase3
                        INTEGER
        }

inletIndex OBJECT-TYPE
        SYNTAX INTEGER (0..3)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to Inlet status entry."
        ::= { pduPwrMonitoringInletStatusEntry 1 }

inletPowerAll OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1W"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The total power of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 2 }

inletResetFrom OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The reset date of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 3 }

inletEnergy OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "KWh"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The total energy of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 4 }

inletStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The Status of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 5 }

inletCurrPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.01A"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase1 current of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 6 }

inletCurrPhase2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.01A"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase2 current of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 7 }

inletCurrPhase3 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.01A"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase3 current of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 8 }

inletVoltPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase1 voltage of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 9 }

inletVoltPhase2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase2 voltage of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 10 }

inletVoltPhase3 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase3 voltage of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 11 }

inletPwrFactorPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase1 power factor of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 12 }

inletPwrFactorPhase2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase2 power factor of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 13 }

inletPwrFactorPhase3 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase3 power factor of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 14 }

inletPowerPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1W"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase1 power of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 15 }

inletPowerPhase2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1W"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase2 power of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 16 }

inletPowerPhase3 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1W"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase3 power of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 17 }

inletStatusPhase1 OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase1 status of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 18 }

inletStatusPhase2 OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase2 status of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 19 }

inletStatusPhase3 OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The phase3 status of inlet."
        ::= { pduPwrMonitoringInletStatusEntry 20 }

-- ===========================================================================
--
-- pduPwrMonitoringInletCfgTable
--
--  Inlet Configuration Group
--
-- ===========================================================================
pduPwrMonitoringInletCfgTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringInletCfgEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to configure thresholds of inlet."
        ::= { pduPwrMonitoringInlet 3}

pduPwrMonitoringInletCfgEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringInletCfgEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to configure thresholds of inlet."
        INDEX  { inletCfgIndex}
        ::= { pduPwrMonitoringInletCfgTable 1 }

PduPwrMonitoringInletCfgEntry ::=
        SEQUENCE {
                inletCfgIndex
                        INTEGER,
                inletCfgLoadCritical
                        INTEGER,
                inletCfgLoadWarning
                        INTEGER,
                inletCfgCurrCritPhase1
                        INTEGER,
                inletCfgCurrCritPhase2
                        INTEGER,
                inletCfgCurrCritPhase3
                        INTEGER,
                inletCfgCurrWarnPhase1
                        INTEGER,
                inletCfgCurrWarnPhase2
                        INTEGER,
                inletCfgCurrWarnPhase3
                        INTEGER,
                inletCfgVoltCritPhase1
                        INTEGER,
                inletCfgVoltCritPhase2
                        INTEGER,
                inletCfgVoltCritPhase3
                        INTEGER,
                inletCfgVoltWarnPhase1
                        INTEGER,
                inletCfgVoltWarnPhase2
                        INTEGER,
                inletCfgVoltWarnPhase3
                        INTEGER
        }

inletCfgIndex OBJECT-TYPE
        SYNTAX INTEGER (0..3)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to inlet configuration entry."
        ::= { pduPwrMonitoringInletCfgEntry 1 }

inletCfgLoadCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1kW"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of inlet load."
        ::= { pduPwrMonitoringInletCfgEntry 2 }

inletCfgLoadWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1kW"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of inlet load."
        ::= { pduPwrMonitoringInletCfgEntry 3 }

inletCfgCurrCritPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of pahse1 current of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 4 }

inletCfgCurrCritPhase2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of pahse2 current of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 5 }

inletCfgCurrCritPhase3 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of pahse3 current of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 6 }

inletCfgCurrWarnPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of pahse1 current of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 7 }

inletCfgCurrWarnPhase2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of pahse2 current of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 8 }

inletCfgCurrWarnPhase3 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of pahse3 current of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 9 }

inletCfgVoltCritPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of pahse1 voltage of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 10 }

inletCfgVoltCritPhase2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of pahse2 voltage of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 11 }

inletCfgVoltCritPhase3 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of pahse3 voltage of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 12 }

inletCfgVoltWarnPhase1 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of pahse1 voltage of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 13 }

inletCfgVoltWarnPhase2 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of pahse2 voltage of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 14 }

inletCfgVoltWarnPhase3 OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1V"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of pahse3 voltage of inlet."
        ::= { pduPwrMonitoringInletCfgEntry 15 }

pduPwrMonitoringOutlet      OBJECT IDENTIFIER ::= { pduPwrMonitoring 2 }
-- ===========================================================================
--
-- pduPwrMonitoringOutlet
--
--  Outlet Management Group of the device.
--
-- ===========================================================================

pduPwrMonitoringOutletPduA    OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 1 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduA
--
--  Outlet of Device1 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduA OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of PduA Outlet."
        ::= { pduPwrMonitoringOutletPduA 1}

-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduA
--
--  Outlet of Device1 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduA OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduAEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of PduA outlet."
        ::= { pduPwrMonitoringOutletPduA 2}

pduPwrMonitoringOutletStatusPduAEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletStatusPduAEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of PduA outlet."
        INDEX  { outletPduAIndex}
        ::= { pduPwrMonitoringOutletStatusTablePduA 1 }

PduPwrMonitoringOutletStatusPduAEntry ::=
        SEQUENCE {
                outletPduAIndex
                        INTEGER,
                outletPduAState
                        INTEGER,
                outletPduACurrent
                        INTEGER,
                outletPduAPwrFactor
                        INTEGER,
                outletPduAPower
                        INTEGER,
                outletPduAEnergy
                        INTEGER,
                outletPduAResetFrom
                        DisplayString,
                outletPduAStatus
                        INTEGER
        }

outletPduAIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet status of PduA."
        ::= { pduPwrMonitoringOutletStatusPduAEntry 1 }

outletPduAState OBJECT-TYPE
        SYNTAX  INTEGER {
                off(1),
                on(2)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The state of PduA outlet."
        ::= { pduPwrMonitoringOutletStatusPduAEntry 2 }

outletPduACurrent OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.01A"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current of PduA outlet."
        ::= { pduPwrMonitoringOutletStatusPduAEntry 3 }

outletPduAPwrFactor OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The power factor of PduA outlet."
        ::= { pduPwrMonitoringOutletStatusPduAEntry 4 }

outletPduAPower OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1W"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The power of PduA outlet."
        ::= { pduPwrMonitoringOutletStatusPduAEntry 5 }

outletPduAEnergy OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "KWh"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The energy of PduA outlet."
        ::= { pduPwrMonitoringOutletStatusPduAEntry 6 }

outletPduAResetFrom OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The reset date of PduA outlet."
        ::= { pduPwrMonitoringOutletStatusPduAEntry 7 }

outletPduAStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The status of PduA outlet."
        ::= { pduPwrMonitoringOutletStatusPduAEntry 8 }

-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduA
--
--  Outlet of Device1 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduA OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduAEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display configuration of PduA outlet."
        ::= { pduPwrMonitoringOutletPduA 3}

pduPwrMonitoringOutletCfgPduAEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletCfgPduAEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display configuration of PduA outlet."
        INDEX  { outletCfgPduAIndex}
        ::= { pduPwrMonitoringOutletCfgTablePduA 1 }

PduPwrMonitoringOutletCfgPduAEntry ::=
        SEQUENCE {
                outletCfgPduAIndex
                        INTEGER,
                outletCfgPduAName
                        DisplayString,
                outletCfgPduADelayOnStatus
                        INTEGER,
                outletCfgPduADelayOnTime
                        INTEGER,
                outletCfgPduADelayOffStatus
                        INTEGER,
                outletCfgPduADelayOffTime
                        INTEGER,
                outletCfgPduAReboot
                        INTEGER,
                outletCfgPduAOverCurrCritical
                        INTEGER,
                outletCfgPduAOverCurrWarning
                        INTEGER,
                outletCfgPduAOverPwrCritical
                        INTEGER,
                outletCfgPduAOverPwrWarning
                        INTEGER
        }

outletCfgPduAIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet configuration of PduA."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 1 }

outletCfgPduAName OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name for outlet of PduA."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 2 }

outletCfgPduADelayOnStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                nodelay(1),
                delay(2)                
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On status of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 3 }

outletCfgPduADelayOnTime OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On time of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 4 }

outletCfgPduADelayOffStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                nodelay(1),
                delay(2)                
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay Off status of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 5 }

outletCfgPduADelayOffTime OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay Off time of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 6 }

outletCfgPduAReboot OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On reboot duration of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 7 }

outletCfgPduAOverCurrCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of current of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 8 }

outletCfgPduAOverCurrWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of current of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 9 }

outletCfgPduAOverPwrCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "1W"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of power of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 10 }

outletCfgPduAOverPwrWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "1W"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of power of PduA outlet."
        ::= { pduPwrMonitoringOutletCfgPduAEntry 11 }

-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduA
--
--  Outlet of Device1 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduA OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduAEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display control of PduA outlet."
        ::= { pduPwrMonitoringOutletPduA 4}

pduPwrMonitoringOutletCtlPduAEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletCtlPduAEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display control of PduA outlet."
        INDEX  { outletCtlPduAIndex}
        ::= { pduPwrMonitoringOutletCtlTablePduA 1 }

PduPwrMonitoringOutletCtlPduAEntry ::=
        SEQUENCE {
                outletCtlPduAIndex
                        INTEGER,
                outletCtlPduAControl
                        INTEGER
        }

outletCtlPduAIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet control of PduA."
        ::= { pduPwrMonitoringOutletCtlPduAEntry 1 }

outletCtlPduAControl OBJECT-TYPE
        SYNTAX  INTEGER {
                immediateOn(1),
                delayedOn(2),
                immediateOff(3),
                delayedOff(4),
                immediateCycle(5),
                delayedCycle(6)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The control-type of PduA outlet."
        ::= { pduPwrMonitoringOutletCtlPduAEntry 2 }

pduPwrMonitoringOutletPduB    OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 2 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduB
--
--  Outlet of Device2 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduB OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of PduB Outlet."
        ::= { pduPwrMonitoringOutletPduB 1}

-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduB
--
--  Outlet of Device2 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduB OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduBEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of PduB outlet."
        ::= { pduPwrMonitoringOutletPduB 2}

pduPwrMonitoringOutletStatusPduBEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletStatusPduBEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of PduB outlet."
        INDEX  { outletPduBIndex}
        ::= { pduPwrMonitoringOutletStatusTablePduB 1 }

PduPwrMonitoringOutletStatusPduBEntry ::=
        SEQUENCE {
                outletPduBIndex
                        INTEGER,
                outletPduBState
                        INTEGER,
                outletPduBCurrent
                        INTEGER,
                outletPduBPwrFactor
                        INTEGER,
                outletPduBPower
                        INTEGER,
                outletPduBEnergy
                        INTEGER,
                outletPduBResetFrom
                        DisplayString,
                outletPduBStatus
                        INTEGER
        }

outletPduBIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet status of PduB."
        ::= { pduPwrMonitoringOutletStatusPduBEntry 1 }

outletPduBState OBJECT-TYPE
        SYNTAX  INTEGER {
                off(1),
                on(2)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The state of PduB outlet."
        ::= { pduPwrMonitoringOutletStatusPduBEntry 2 }

outletPduBCurrent OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.01A"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current of PduB outlet."
        ::= { pduPwrMonitoringOutletStatusPduBEntry 3 }

outletPduBPwrFactor OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The power factor of PduB outlet."
        ::= { pduPwrMonitoringOutletStatusPduBEntry 4 }

outletPduBPower OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1W"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The power of PduB outlet."
        ::= { pduPwrMonitoringOutletStatusPduBEntry 5 }

outletPduBEnergy OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "KWh"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The energy of PduB outlet."
        ::= { pduPwrMonitoringOutletStatusPduBEntry 6 }

outletPduBResetFrom OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The reset date of PduB outlet."
        ::= { pduPwrMonitoringOutletStatusPduBEntry 7 }

outletPduBStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The status of PduB outlet."
        ::= { pduPwrMonitoringOutletStatusPduBEntry 8 }

-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduB
--
--  Outlet of Device2 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduB OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduBEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display configuration of PduB outlet."
        ::= { pduPwrMonitoringOutletPduB 3}

pduPwrMonitoringOutletCfgPduBEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletCfgPduBEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display configuration of PduB outlet."
        INDEX  { outletCfgPduBIndex}
        ::= { pduPwrMonitoringOutletCfgTablePduB 1 }

PduPwrMonitoringOutletCfgPduBEntry ::=
        SEQUENCE {
                outletCfgPduBIndex
                        INTEGER,
                outletCfgPduBName
                        DisplayString,
                outletCfgPduBDelayOnStatus
                        INTEGER,
                outletCfgPduBDelayOnTime
                        INTEGER,
                outletCfgPduBDelayOffStatus
                        INTEGER,
                outletCfgPduBDelayOffTime
                        INTEGER,
                outletCfgPduBReboot
                        INTEGER,
                outletCfgPduBOverCurrCritical
                        INTEGER,
                outletCfgPduBOverCurrWarning
                        INTEGER,
                outletCfgPduBOverPwrCritical
                        INTEGER,
                outletCfgPduBOverPwrWarning
                        INTEGER
        }

outletCfgPduBIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet configuration of PduB."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 1 }

outletCfgPduBName OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name for outlet of PduB."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 2 }

outletCfgPduBDelayOnStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                nodelay(1),
                delay(2)                
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On status of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 3 }

outletCfgPduBDelayOnTime OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On time of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 4 }

outletCfgPduBDelayOffStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                nodelay(1),
                delay(2)                
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay Off status of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 5 }

outletCfgPduBDelayOffTime OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay Off time of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 6 }

outletCfgPduBReboot OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On reboot duration of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 7 }

outletCfgPduBOverCurrCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of current of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 8 }

outletCfgPduBOverCurrWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of current of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 9 }

outletCfgPduBOverPwrCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "1W"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of power of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 10 }

outletCfgPduBOverPwrWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "1W"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of power of PduB outlet."
        ::= { pduPwrMonitoringOutletCfgPduBEntry 11 }

-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduB
--
--  Outlet of Device2 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduB OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduBEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display control of PduB outlet."
        ::= { pduPwrMonitoringOutletPduB 4}

pduPwrMonitoringOutletCtlPduBEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletCtlPduBEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display control of PduB outlet."
        INDEX  { outletCtlPduBIndex}
        ::= { pduPwrMonitoringOutletCtlTablePduB 1 }

PduPwrMonitoringOutletCtlPduBEntry ::=
        SEQUENCE {
                outletCtlPduBIndex
                        INTEGER,
                outletCtlPduBControl
                        INTEGER
        }

outletCtlPduBIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet control of PduB."
        ::= { pduPwrMonitoringOutletCtlPduBEntry 1 }

outletCtlPduBControl OBJECT-TYPE
        SYNTAX  INTEGER {
                immediateOn(1),
                delayedOn(2),
                immediateOff(3),
                delayedOff(4),
                immediateCycle(5),
                delayedCycle(6)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The control-type of PduB outlet."
        ::= { pduPwrMonitoringOutletCtlPduBEntry 2 }

pduPwrMonitoringOutletPduC    OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 3 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduC
--
--  Outlet of Device3 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduC OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of PduC Outlet."
        ::= { pduPwrMonitoringOutletPduC 1}

-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduC
--
--  Outlet of Device3 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduC OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduCEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of PduC outlet."
        ::= { pduPwrMonitoringOutletPduC 2}

pduPwrMonitoringOutletStatusPduCEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletStatusPduCEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of PduC outlet."
        INDEX  { outletPduCIndex}
        ::= { pduPwrMonitoringOutletStatusTablePduC 1 }

PduPwrMonitoringOutletStatusPduCEntry ::=
        SEQUENCE {
                outletPduCIndex
                        INTEGER,
                outletPduCState
                        INTEGER,
                outletPduCCurrent
                        INTEGER,
                outletPduCPwrFactor
                        INTEGER,
                outletPduCPower
                        INTEGER,
                outletPduCEnergy
                        INTEGER,
                outletPduCResetFrom
                        DisplayString,
                outletPduCStatus
                        INTEGER
        }

outletPduCIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet status of PduC."
        ::= { pduPwrMonitoringOutletStatusPduCEntry 1 }

outletPduCState OBJECT-TYPE
        SYNTAX  INTEGER {
                off(1),
                on(2)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The state of PduC outlet."
        ::= { pduPwrMonitoringOutletStatusPduCEntry 2 }

outletPduCCurrent OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.01A"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current of PduC outlet."
        ::= { pduPwrMonitoringOutletStatusPduCEntry 3 }

outletPduCPwrFactor OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The power factor of PduC outlet."
        ::= { pduPwrMonitoringOutletStatusPduCEntry 4 }

outletPduCPower OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1W"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The power of PduC outlet."
        ::= { pduPwrMonitoringOutletStatusPduCEntry 5 }

outletPduCEnergy OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "KWh"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The energy of PduC outlet."
        ::= { pduPwrMonitoringOutletStatusPduCEntry 6 }

outletPduCResetFrom OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The reset date of PduC outlet."
        ::= { pduPwrMonitoringOutletStatusPduCEntry 7 }

outletPduCStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The status of PduC outlet."
        ::= { pduPwrMonitoringOutletStatusPduCEntry 8 }

-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduC
--
--  Outlet of Device3 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduC OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduCEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display configuration of PduC outlet."
        ::= { pduPwrMonitoringOutletPduC 3}

pduPwrMonitoringOutletCfgPduCEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletCfgPduCEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display configuration of PduC outlet."
        INDEX  { outletCfgPduCIndex}
        ::= { pduPwrMonitoringOutletCfgTablePduC 1 }

PduPwrMonitoringOutletCfgPduCEntry ::=
        SEQUENCE {
                outletCfgPduCIndex
                        INTEGER,
                outletCfgPduCName
                        DisplayString,
                outletCfgPduCDelayOnStatus
                        INTEGER,
                outletCfgPduCDelayOnTime
                        INTEGER,
                outletCfgPduCDelayOffStatus
                        INTEGER,
                outletCfgPduCDelayOffTime
                        INTEGER,
                outletCfgPduCReboot
                        INTEGER,
                outletCfgPduCOverCurrCritical
                        INTEGER,
                outletCfgPduCOverCurrWarning
                        INTEGER,
                outletCfgPduCOverPwrCritical
                        INTEGER,
                outletCfgPduCOverPwrWarning
                        INTEGER
        }

outletCfgPduCIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet configuration of PduC."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 1 }

outletCfgPduCName OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name for outlet of PduC."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 2 }

outletCfgPduCDelayOnStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                nodelay(1),
                delay(2)                
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On status of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 3 }

outletCfgPduCDelayOnTime OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On time of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 4 }

outletCfgPduCDelayOffStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                nodelay(1),
                delay(2)                
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay Off status of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 5 }

outletCfgPduCDelayOffTime OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay Off time of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 6 }

outletCfgPduCReboot OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On reboot duration of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 7 }

outletCfgPduCOverCurrCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of current of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 8 }

outletCfgPduCOverCurrWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of current of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 9 }

outletCfgPduCOverPwrCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "1W"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of power of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 10 }

outletCfgPduCOverPwrWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "1W"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of power of PduC outlet."
        ::= { pduPwrMonitoringOutletCfgPduCEntry 11 }

-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduC
--
--  Outlet of Device3 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduC OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduCEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display control of PduC outlet."
        ::= { pduPwrMonitoringOutletPduC 4}

pduPwrMonitoringOutletCtlPduCEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletCtlPduCEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display control of PduC outlet."
        INDEX  { outletCtlPduCIndex}
        ::= { pduPwrMonitoringOutletCtlTablePduC 1 }

PduPwrMonitoringOutletCtlPduCEntry ::=
        SEQUENCE {
                outletCtlPduCIndex
                        INTEGER,
                outletCtlPduCControl
                        INTEGER
        }

outletCtlPduCIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet control of PduC."
        ::= { pduPwrMonitoringOutletCtlPduCEntry 1 }

outletCtlPduCControl OBJECT-TYPE
        SYNTAX  INTEGER {
                immediateOn(1),
                delayedOn(2),
                immediateOff(3),
                delayedOff(4),
                immediateCycle(5),
                delayedCycle(6)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The control-type of PduC outlet."
        ::= { pduPwrMonitoringOutletCtlPduCEntry 2 }

pduPwrMonitoringOutletPduD    OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 4 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduD
--
--  Outlet of Device4 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduD OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of PduD Outlet."
        ::= { pduPwrMonitoringOutletPduD 1}

-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduD
--
--  Outlet of Device3 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduD OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduDEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of PduD outlet."
        ::= { pduPwrMonitoringOutletPduD 2}

pduPwrMonitoringOutletStatusPduDEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletStatusPduDEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display status of PduD outlet."
        INDEX  { outletPduDIndex}
        ::= { pduPwrMonitoringOutletStatusTablePduD 1 }

PduPwrMonitoringOutletStatusPduDEntry ::=
        SEQUENCE {
                outletPduDIndex
                        INTEGER,
                outletPduDState
                        INTEGER,
                outletPduDCurrent
                        INTEGER,
                outletPduDPwrFactor
                        INTEGER,
                outletPduDPower
                        INTEGER,
                outletPduDEnergy
                        INTEGER,
                outletPduDResetFrom
                        DisplayString,
                outletPduDStatus
                        INTEGER
        }

outletPduDIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet status of PduD."
        ::= { pduPwrMonitoringOutletStatusPduDEntry 1 }

outletPduDState OBJECT-TYPE
        SYNTAX  INTEGER {
                off(1),
                on(2)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The state of PduD outlet."
        ::= { pduPwrMonitoringOutletStatusPduDEntry 2 }

outletPduDCurrent OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.01A"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The current of PduD outlet."
        ::= { pduPwrMonitoringOutletStatusPduDEntry 3 }

outletPduDPwrFactor OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The power factor of PduD outlet."
        ::= { pduPwrMonitoringOutletStatusPduDEntry 4 }

outletPduDPower OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1W"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The power of PduD outlet."
        ::= { pduPwrMonitoringOutletStatusPduDEntry 5 }

outletPduDEnergy OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "KWh"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The energy of PduD outlet."
        ::= { pduPwrMonitoringOutletStatusPduDEntry 6 }

outletPduDResetFrom OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The reset date of PduD outlet."
        ::= { pduPwrMonitoringOutletStatusPduDEntry 7 }

outletPduDStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The status of PduD outlet."
        ::= { pduPwrMonitoringOutletStatusPduDEntry 8 }

-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduD
--
--  Outlet of Device4 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduD OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduDEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display configuration of PduD outlet."
        ::= { pduPwrMonitoringOutletPduD 3}

pduPwrMonitoringOutletCfgPduDEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletCfgPduDEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display configuration of PduD outlet."
        INDEX  { outletCfgPduDIndex}
        ::= { pduPwrMonitoringOutletCfgTablePduD 1 }

PduPwrMonitoringOutletCfgPduDEntry ::=
        SEQUENCE {
                outletCfgPduDIndex
                        INTEGER,
                outletCfgPduDName
                        DisplayString,
                outletCfgPduDDelayOnStatus
                        INTEGER,
                outletCfgPduDDelayOnTime
                        INTEGER,
                outletCfgPduDDelayOffStatus
                        INTEGER,
                outletCfgPduDDelayOffTime
                        INTEGER,
                outletCfgPduDReboot
                        INTEGER,
                outletCfgPduDOverCurrCritical
                        INTEGER,
                outletCfgPduDOverCurrWarning
                        INTEGER,
                outletCfgPduDOverPwrCritical
                        INTEGER,
                outletCfgPduDOverPwrWarning
                        INTEGER
        }

outletCfgPduDIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet configuration of PduD."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 1 }

outletCfgPduDName OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name for outlet of PduD."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 2 }

outletCfgPduDDelayOnStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                nodelay(1),
                delay(2)                
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On status of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 3 }

outletCfgPduDDelayOnTime OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On time of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 4 }

outletCfgPduDDelayOffStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                nodelay(1),
                delay(2)                
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay Off status of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 5 }

outletCfgPduDDelayOffTime OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay Off time of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 6 }

outletCfgPduDReboot OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "seconds"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay On reboot duration of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 7 }

outletCfgPduDOverCurrCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of current of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 8 }

outletCfgPduDOverCurrWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1A"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of current of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 9 }

outletCfgPduDOverPwrCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "1W"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Critical Threshold of power of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 10 }

outletCfgPduDOverPwrWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "1W"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Warning Threshold of power of PduD outlet."
        ::= { pduPwrMonitoringOutletCfgPduDEntry 11 }

-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduD
--
--  Outlet of Device4 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduD OBJECT-TYPE
        SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduDEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display control of PduD outlet."
        ::= { pduPwrMonitoringOutletPduD 4}

pduPwrMonitoringOutletCtlPduDEntry OBJECT-TYPE
        SYNTAX PduPwrMonitoringOutletCtlPduDEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list to display control of PduD outlet."
        INDEX  { outletCtlPduDIndex}
        ::= { pduPwrMonitoringOutletCtlTablePduD 1 }

PduPwrMonitoringOutletCtlPduDEntry ::=
        SEQUENCE {
                outletCtlPduDIndex
                        INTEGER,
                outletCtlPduDControl
                        INTEGER
        }

outletCtlPduDIndex OBJECT-TYPE
        SYNTAX INTEGER (0..41)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to outlet control of PduD."
        ::= { pduPwrMonitoringOutletCtlPduDEntry 1 }

outletCtlPduDControl OBJECT-TYPE
        SYNTAX  INTEGER {
                immediateOn(1),
                delayedOn(2),
                immediateOff(3),
                delayedOff(4),
                immediateCycle(5),
                delayedCycle(6)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The control-type of PduD outlet."
        ::= { pduPwrMonitoringOutletCtlPduDEntry 2 }

pduEnvMonitoringStatus      OBJECT IDENTIFIER ::= { pduEnvMonitoring 1 }
-- ===========================================================================
--
-- pduEnvMonitoringStatus
--
--  Emd Status Group.
--
-- ===========================================================================
pduEnvMonitoringTemp OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "degC"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The temperature of EMD."
        ::= { pduEnvMonitoringStatus 1 }

pduEnvMonitoringHumi OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The humidity of EMD."
        ::= { pduEnvMonitoringStatus 2 }

pduEnvMonitoringTempAlarm OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The temperature status of EMD."
        ::= { pduEnvMonitoringStatus 3 }

pduEnvMonitoringHumiAlarm OBJECT-TYPE
        SYNTAX  INTEGER {
                normal(1),
                warning(2),
                critical(3)                
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The humidity status of EMD."
        ::= { pduEnvMonitoringStatus 4 }

pduEnvMonitoringCfg      OBJECT IDENTIFIER ::= { pduEnvMonitoring 2 }
-- ===========================================================================
--
-- pduEnvMonitoringCfg
--
--  Emd Configuration Group.
--
-- ===========================================================================
pduEnvMonitoringControl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                enabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the EMD."
        ::= { pduEnvMonitoringCfg 1 }

pduEnvMonitoringTempHighCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "degC"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The High Critical Threshold of temperature of EMD."
        ::= { pduEnvMonitoringCfg 2 }

pduEnvMonitoringTempHighWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "degC"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The High Warning Threshold of temperature of EMD."
        ::= { pduEnvMonitoringCfg 3 }

pduEnvMonitoringTempLowCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "degC"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Low Critical Threshold of temperature of EMD."
        ::= { pduEnvMonitoringCfg 4 }

pduEnvMonitoringTempLowWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "degC"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Low Warning Threshold of temperature of EMD."
        ::= { pduEnvMonitoringCfg 5 }

pduEnvMonitoringTempHystersis OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "degC"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Hystersis of Temperature of EMD."
        ::= { pduEnvMonitoringCfg 6 }

pduEnvMonitoringTempOffset OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "degC"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Offset of Temperature of EMD."
        ::= { pduEnvMonitoringCfg 7 }

pduEnvMonitoringHumiHighCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The High Crtitcal Threshold of humidity of EMD."
        ::= { pduEnvMonitoringCfg 8 }

pduEnvMonitoringHumiHighWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The High Warning Threshold of humidity of EMD."
        ::= { pduEnvMonitoringCfg 9 }

pduEnvMonitoringHumiLowCritical OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Low Crtitcal Threshold of humidity of EMD."
        ::= { pduEnvMonitoringCfg 10 }

pduEnvMonitoringHumiLowWarning OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Low Warning Threshold of humidity of EMD."
        ::= { pduEnvMonitoringCfg 11 }

pduEnvMonitoringHumiHystersis OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Hystersis of Humidity of EMD."
        ::= { pduEnvMonitoringCfg 12 }

pduEnvMonitoringHumiOffset OBJECT-TYPE
        SYNTAX INTEGER
        UNITS  "0.1%"
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Ofset of Humidity of EMD."
        ::= { pduEnvMonitoringCfg 13 }

-- ===========================================================================
-- pduTraps
--
-- iPoManIII Trap group
-- ===========================================================================

   -- This section defines the well-known notifications sent by
   -- agents.

pduSystemColdBoot TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Cold boot."
        ::= 1

pduSystemWarmBoot TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Warm boot."
        ::= 2

pduSystemRestart TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: System restart."
        ::= 3

pduResetToDefault TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Parameters reset to default."
        ::= 4

pduFirmUpgrade TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Firmware upgrade."
        ::= 5

pduSystemLogClear TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: System log cleared."
        ::= 6

pduEventlogClear TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Event log cleared."
        ::= 7

pduInletHistoryClear TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet history log cleared."
        ::= 8

pduOutletHistoryClear TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet history log cleared."
        ::= 9

pduSystemTimeChangeUser TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Time changed by user."
        ::= 10

pduSystemTimeChangeNtp TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Time synced with NTP server."
        ::= 11

pduSystemTimeChangeRtc TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Time changed by RTC."
        ::= 12

pduMailTestPass TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Test mail pass."
        ::= 13

pduMailTestFail TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Test mail failed."
        ::= 14

pduMailSentPass TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Mail sent successfully."
        ::= 15

pduMailSentFail TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Mail sent failed."
        ::= 16

pduSystemCfgChange TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Parameter changed."
        ::= 17

pduSystemParamImport TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Import XML configuration."
        ::= 18

pduInletCommLost TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet communication lost."
        ::= 19

pduInletCommRestore TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet communication restore."
        ::= 20
		
pduOutletCommLost TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet communication lost."
        ::= 21

pduOutletCommRestore TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet communication restore"
        ::= 22

pduOutletOnUser TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet turned on by user."
        ::= 23

pduOutletOnSchedule TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet turned on by schedule."
        ::= 24

pduOutletOffUser TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet turned off by user."
        ::= 25

pduOutletOffSchedule TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet turned off by schedule."
        ::= 26
        
pduOutletRebootUser TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet reboot by user."
        ::= 27

pduOutletRebootSchedule TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet reboot by schedule."
        ::= 28

pduInletEnergyReset TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet energy reset."
        ::= 29

pduOutletEnergyReset TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet energy reset."
        ::= 30

pduSetUser TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Assign outlet to user."
        ::= 31

pduDeletUser TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Delete user."
        ::= 32

pduUpgradeInletSuccess TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet upgrade successfully."
        ::= 33

pduUpgradeInletFail TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet upgrade fail."
        ::= 34

pduUpgradeOutletSuccess TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet upgrade successfully."
        ::= 35

pduUpgradeOutletFail TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet upgrade fail."
        ::= 36

pduEmdTempHighWarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Temperature had returned from high warning to normal."
        ::= 101

pduEmdTempHighWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Temperature was higher than high warning set point."
        ::= 102

pduEmdTempLowWarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Temperature had returned from low warning to normal."
        ::= 103

pduEmdTempLowWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Temperature was lower than low warning set point."
        ::= 104

pduEmdTempHighCritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Temperature had returned from high critical to high warning."
        ::= 105

pduEmdTempHighCritical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Temperature was higher than high critical set point."
        ::= 106

pduEmdTempLowCritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Temperature had returned from low critical to low warning."
        ::= 107

pduEmdTempLowCritical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Temperature was lower than low critical set point."
        ::= 108

pduEmdHumiHighWarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Humidity had returned from high warning to normal."
        ::= 109

pduEmdHumiHighWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Humidity was higher than high warning set point."
        ::= 110

pduEmdHumiLowWarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Humidity had returned from low warning to normal."
        ::= 111

pduEmdHumiLowWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Humidity was lower than low warning set point."
        ::= 112

pduEmdHumiHighCritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Humidity had returned from high critical to high warning."
        ::= 113

pduEmdHumiHighCritical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Humidity was higher than high critical set point."
        ::= 114
        
pduEmdHumiLowCritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Humidity had returned from low critical to low warning."
        ::= 115

pduEmdHumiLowCritical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Humidity was lower than low critical set point."
        ::= 116

pduEmdAlarm1NotActive TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Alarm-1 became inactive."
        ::= 117

pduEmdAlarm1Active TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Alarm-1 became active."
        ::= 118

pduEmdAlarm2NotActive TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Alarm-2 became inactive."
        ::= 119

pduEmdAlarm2Active TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Alarm-2 became active."
        ::= 120

pduRs485Online TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: RS485 Sensor was online."
        ::= 121

pduRs485Offline TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: RS485 Sensor was offline."
        ::= 122

pduInletLoadCritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet load had returned from critical to warning."
        ::= 123

pduInletLoadCritical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Inlet load was higher than critical set point."
        ::= 124

pduInletLoadWarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet load had returned from warning to normal."
        ::= 125

pduInletLoadWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Inlet load was higher than warning set point."
        ::= 126

pduInletCurrPhase1CritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase1 current had returned from critical to warning."
        ::= 127

pduInletCurrPhase1Critical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Inlet phase1 current was higher than critical set point."
        ::= 128

pduInletCurrPhase1WarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase1 current had returned from warning to normal."
        ::= 129

pduInletCurrPhase1Warn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Inlet phase1 current was higher than warning set point."
        ::= 130

pduInletCurrPhase2CritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase2 current had returned from critical to warning."
        ::= 131

pduInletCurrPhase2Critical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Inlet phase2 current was higher than critical set point."
        ::= 132

pduInletCurrPhase2WarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase2 current had returned from warning to normal."
        ::= 133

pduInletCurrPhase2Warn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Inlet phase2 current was higher than warning set point."
        ::= 134


pduInletCurrPhase3CritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase3 current had returned from critical to warning."
        ::= 135

pduInletCurrPhase3Critical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Inlet phase3 current was higher than critical set point."
        ::= 136

pduInletCurrPhase3WarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase3 current had returned from warning to normal."
        ::= 137

pduInletCurrPhase3Warn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Inlet phase3 current had returned from critical to warning."
        ::= 138

pduInletVoltPhase1CritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase1 voltage had returned from critical to warning."
        ::= 139

pduInletVoltPhase1Critical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Inlet phase1 voltage was higher than critical set point."
        ::= 140

pduInletVoltPhase1WarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase1 voltage had returned from warning to normal."
        ::= 141

pduInletVoltPhase1Warn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Inlet phase1 voltage was higher than warning set point."
        ::= 142

pduInletVoltPhase2CritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase2 voltage had returned from critical to warning."
        ::= 143

pduInletVoltPhase2Critical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Inlet phase2 voltage was higher than critical set point."
        ::= 144

pduInletVoltPhase2WarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase2 voltage had returned from warning to normal."
        ::= 145

pduInletVoltPhase2Warn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Inlet phase2 voltage was higher than warning set point."
        ::= 146

pduInletVoltPhase3CritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase3 voltage had returned from critical to warning."
        ::= 147

pduInletVoltPhase3Critical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Inlet phase3 voltage was higher than critical set point."
        ::= 148

pduInletVoltPhase3WarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Inlet phase3 voltage had returned from warning to normal."
        ::= 149

pduInletVoltPhase3Warn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Inlet phase3 voltage was higher than warning set point."
        ::= 150

pduOutletCurrCritToWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet current had returned from critical to warning."
        ::= 151

pduOutletCurrCritical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Outlet current was higher than critical set point."
        ::= 152

pduOutletCurrWarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet current had returned from warning to normal."
        ::= 153

pduOutletCurrWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Outlet current was higher than warning set point."
        ::= 154

pduOutletPwrCritTOWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet power had returned from critical to warning."
        ::= 155

pduOutletPwrCritical TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Critical: Outlet power was higher than critical set point."
        ::= 156

pduOutletPwrWarnToNormal TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Outlet power had returned from warning to normal."
        ::= 157

pduOutletPwrWarn TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Warning: Outlet power was higher than warning set point."
        ::= 158

pduAlarm1Disabled TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Alarm-1 became disabled."
        ::= 159

pduAlarm2Disabled TRAP-TYPE
        ENTERPRISE pduTraps
        DESCRIPTION
                "Informational: Alarm-2 became disabled."
        ::= 160

END        